Siyu (Steven) Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Siyu (Steven) Lin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Haowen Zhou
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
3 shared publications Changhuei Yang
Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
2 shared publications- Ruizhi Cao
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
2 shared publications - Shi Zhao
Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, United States of America
2 shared publications - Brandon Yushan Feng
Department of Computer Science, University of Maryland, College Park, MD 20742 USA
1 shared publication - Changhuei Yang
Department of Electrical Engineering, California Institute of Technology, Pasadena, USA
1 shared publication
Latest Publications
- 27 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1666-1677
Dome-APIC illumination design for high space-bandwidth product analytic imaging
Breaking the tradeoff between resolution and field-of-view, while obtaining distortion-free images, can be achieved through computational imaging techniques. A recent approach, Angular Ptychographic Imaging with Close-form method (APIC), has showcased its capability to analytically recover both intricate aberrations and high space-bandwidth product complex optical fields with NA-matching and darkfield illuminations. However, its flat illumination setup limits its ability to efficiently reconstruct a large field-of-view simultaneously with high resolution, owing to the curvature in the wavefront from NA-matching illuminations and the finite beam angle of the Lambertian LED light source. Here, we introduce an illumination framework tailored for APIC consisting of a distant annular LED ring and an LED dome that enables the reconstruction of a larger area with an extended synthetic numerical aperture, consequently enhancing resolution. For a single set of measurements, our new prototype, termed Dome-APIC can reach 620nm resolution with a 10×/0.25 NA objective lens over a field-of-view of 450 µm x 450 µm.
- 27 March 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (4) , 1666-1677
Dome-APIC illumination design for high space-bandwidth product analytic imaging
Breaking the tradeoff between resolution and field-of-view, while obtaining distortion-free images, can be achieved through computational imaging techniques. A recent approach, Angular Ptychographic Imaging with Close-form method (APIC), has showcased its capability to analytically recover both intricate aberrations and high space-bandwidth product complex optical fields with NA-matching and darkfield illuminations. However, its flat illumination setup limits its ability to efficiently reconstruct a large field-of-view simultaneously with high resolution, owing to the curvature in the wavefront from NA-matching illuminations and the finite beam angle of the Lambertian LED light source. Here, we introduce an illumination framework tailored for APIC consisting of a distant annular LED ring and an LED dome that enables the reconstruction of a larger area with an extended synthetic numerical aperture, consequently enhancing resolution. For a single set of measurements, our new prototype, termed Dome-APIC can reach 620nm resolution with a 10×/0.25 NA objective lens over a field-of-view of 450 µm x 450 µm.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5739-5755
Efficient, gigapixel-scale, aberration-free whole slide scanner using angular ptychographic imaging with closed-form solution
Whole slide imaging provides a wide field-of-view (FOV) across cross-sections of biopsy or surgery samples, significantly facilitating pathological analysis and clinical diagnosis. Such high-quality images that enable detailed visualization of cellular and tissue structures are essential for effective patient care and treatment planning. To obtain such high-quality images for pathology applications, there is a need for scanners with high spatial bandwidth products, free from aberrations, and without the requirement for z-scanning. Here we report a whole slide imaging system based on angular ptychographic imaging with a closed-form solution (WSI-APIC), which offers efficient, tens-of-gigapixels, large-FOV, aberration-free imaging. WSI-APIC utilizes oblique incoherent illumination for initial high-level segmentation, thereby bypassing unnecessary scanning of the background regions and enhancing image acquisition efficiency. A GPU-accelerated APIC algorithm analytically reconstructs phase images with effective digital aberration corrections and improved optical resolutions. Moreover, an auto-stitching technique based on scale-invariant feature transform ensures the seamless concatenation of whole slide phase images. In our experiment, WSI-APIC achieved an optical resolution of 772 nm using a 10×/0.25 NA objective lens and captures 80-gigapixel aberration-free phase images for a standard 76.2 mm × 25.4 mm microscopic slide.
- 6 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 5739-5755
Efficient, gigapixel-scale, aberration-free whole slide scanner using angular ptychographic imaging with closed-form solution
Whole slide imaging provides a wide field-of-view (FOV) across cross-sections of biopsy or surgery samples, significantly facilitating pathological analysis and clinical diagnosis. Such high-quality images that enable detailed visualization of cellular and tissue structures are essential for effective patient care and treatment planning. To obtain such high-quality images for pathology applications, there is a need for scanners with high spatial bandwidth products, free from aberrations, and without the requirement for z-scanning. Here we report a whole slide imaging system based on angular ptychographic imaging with a closed-form solution (WSI-APIC), which offers efficient, tens-of-gigapixels, large-FOV, aberration-free imaging. WSI-APIC utilizes oblique incoherent illumination for initial high-level segmentation, thereby bypassing unnecessary scanning of the background regions and enhancing image acquisition efficiency. A GPU-accelerated APIC algorithm analytically reconstructs phase images with effective digital aberration corrections and improved optical resolutions. Moreover, an auto-stitching technique based on scale-invariant feature transform ensures the seamless concatenation of whole slide phase images. In our experiment, WSI-APIC achieved an optical resolution of 772 nm using a 10×/0.25 NA objective lens and captures 80-gigapixel aberration-free phase images for a standard 76.2 mm × 25.4 mm microscopic slide.
- Top Cited Papers
- 14 December 2023
- Published by Optica Publishing Group in Optica
- Vol. 10 (12) , 1679-1687
Fourier ptychographic microscopy image stack reconstruction using implicit neural representations
Image stacks provide invaluable 3D information in various biological and pathological imaging applications. Fourier ptychographic microscopy (FPM) enables reconstructing high-resolution, wide field-of-view image stacks without z-stack scanning, thus significantly accelerating image acquisition. However, existing FPM methods take tens of minutes to reconstruct and gigabytes of memory to store a high-resolution volumetric scene, impeding fast gigapixel-scale remote digital pathology. While deep learning approaches have been explored to address this challenge, existing methods poorly generalize to novel datasets and can produce unreliable hallucinations. This work presents FPM-INR, a compact and efficient framework that integrates physics-based optical models with implicit neural representations (INRs) to represent and reconstruct FPM image stacks. FPM-INR is agnostic to system design or sample types and does not require external training data. In our experiments, FPM-INR substantially outperforms traditional FPM algorithms with up to a 25-fold increase in speed and an 80-fold reduction in memory usage for continuous image stack representations.
- 14 December 2023
- Published by Optica Publishing Group in Optica
- Vol. 10 (12) , 1679-1687
Top Cited PapersFourier ptychographic microscopy image stack reconstruction using implicit neural representations
Image stacks provide invaluable 3D information in various biological and pathological imaging applications. Fourier ptychographic microscopy (FPM) enables reconstructing high-resolution, wide field-of-view image stacks without z-stack scanning, thus significantly accelerating image acquisition. However, existing FPM methods take tens of minutes to reconstruct and gigabytes of memory to store a high-resolution volumetric scene, impeding fast gigapixel-scale remote digital pathology. While deep learning approaches have been explored to address this challenge, existing methods poorly generalize to novel datasets and can produce unreliable hallucinations. This work presents FPM-INR, a compact and efficient framework that integrates physics-based optical models with implicit neural representations (INRs) to represent and reconstruct FPM image stacks. FPM-INR is agnostic to system design or sample types and does not require external training data. In our experiments, FPM-INR substantially outperforms traditional FPM algorithms with up to a 25-fold increase in speed and an 80-fold reduction in memory usage for continuous image stack representations.