Ziao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ziao Liu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jixi Lu
Beihang University
8 shared publications - Xiaoyu Li
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
6 shared publications - Jianwei Sheng
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Zhongyu Wang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Bangcheng Han
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
2 shared publications - Di Zhan
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 14 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Nuclear spin signal reconstruction and effective-field estimation based on vector response modeling of a co-magnetometer
- 14 September 2026
- Published by Elsevier in Measurement
- Vol. 291
Nuclear spin signal reconstruction and effective-field estimation based on vector response modeling of a co-magnetometer
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Response Model of Naturally Abundant Rubidium SERF Magnetomete
Spin-exchange relaxation-free (SERF) atomic magnetometers are widely utilized due to high sensitivity and promising miniaturization capability. Alkali vapor cells filled with 87Rb are commonly employed as the core component, while facing challenges of high cost and difficulty in scalable production. Replacing 87Rb with naturally abundant rubidium (natRb) in vapor cell fabrication can substantially reduce the cost of isotopic enrichment. In this study, we conduct comparative analyses of rubidium isotopes and determine that the gyromagnetic ratio difference between natRb and 87Rb arises from their distinct nuclear spins, which results in the polarization-dependent slowing-down phenomenon. Under the SERF regime, a hybrid slowing-down factor of the natRb ensemble is formulated based on equilibrium mass-dependent isotopic fractionation theory. We then analyze relaxation rate differences between ${}^{\text{nat}}$ Rb and 87Rb vapor cells and ultimately establish the response model of the ${}^{\text{nat}}$ Rb SERF magnetometer. The result demonstrates that optimizing the buffer gas pressure allows the ${}^{\text{nat}}$ Rb magnetometer to achieve a response signal close to that of the 87Rb device, enabling comparable sensitivity. Experiments conducted using 8 mm cubic vapor cells as a representative case revealed that the response signal of the ${}^{\text{nat}}$ Rb magnetometer was approximately only 19% lower than that of the 87Rb device, with a comparable increase in probe noise. This led to a slight yet engineering-tolerable difference in sensitivity. These results indicate that ${}^{\text{nat}}$ Rb provides a practical and cost-effective alternative to 87Rb in high-sensitivity applications. The presented model can be extended to arbitrary cell sizes and other alkali species.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Response Model of Naturally Abundant Rubidium SERF Magnetomete
Spin-exchange relaxation-free (SERF) atomic magnetometers are widely utilized due to high sensitivity and promising miniaturization capability. Alkali vapor cells filled with 87Rb are commonly employed as the core component, while facing challenges of high cost and difficulty in scalable production. Replacing 87Rb with naturally abundant rubidium (natRb) in vapor cell fabrication can substantially reduce the cost of isotopic enrichment. In this study, we conduct comparative analyses of rubidium isotopes and determine that the gyromagnetic ratio difference between natRb and 87Rb arises from their distinct nuclear spins, which results in the polarization-dependent slowing-down phenomenon. Under the SERF regime, a hybrid slowing-down factor of the natRb ensemble is formulated based on equilibrium mass-dependent isotopic fractionation theory. We then analyze relaxation rate differences between ${}^{\text{nat}}$ Rb and 87Rb vapor cells and ultimately establish the response model of the ${}^{\text{nat}}$ Rb SERF magnetometer. The result demonstrates that optimizing the buffer gas pressure allows the ${}^{\text{nat}}$ Rb magnetometer to achieve a response signal close to that of the 87Rb device, enabling comparable sensitivity. Experiments conducted using 8 mm cubic vapor cells as a representative case revealed that the response signal of the ${}^{\text{nat}}$ Rb magnetometer was approximately only 19% lower than that of the 87Rb device, with a comparable increase in probe noise. This led to a slight yet engineering-tolerable difference in sensitivity. These results indicate that ${}^{\text{nat}}$ Rb provides a practical and cost-effective alternative to 87Rb in high-sensitivity applications. The presented model can be extended to arbitrary cell sizes and other alkali species.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes
Accurate magnetic source reconstruction critically depends on high-sensitivity multi-axis measurements. Given the superior sensitivity provided by the spin-exchange relaxation-free (SERF) regime, the development of high-sensitivity multi-axis atomic magnetometers (AMs) based on SERF is of paramount importance. However, most existing multi-axis AMs rely on multiple high-frequency modulated magnetic fields, increasing the spin-exchange relaxation and leading to the complex crosstalk between nearby magnetometers in array applications, thus limiting the measurement performance. In this study, we propose a method for magnetic field measurement with tunable sensitive axes, based on all-optical dual-axis measurements. This method adjusts the direction of atomic spin precession by applying a bias magnetic field. It allows for flexible switching between the transverse dual-axis and longitudinal axis as needed, without introducing complex multi-axis modulated magnetic fields. Experimental results demonstrate transverse dual-axis sensitivities are 3 fT/Hz1/2 for the x-axis and 2 fT/Hz1/2 for the y-axis, while the longitudinal sensitivity for the z-axis is 6 fT/Hz1/2 after switching the sensitive axis. Our approach offers significant advantages over existing methods, particularly in eliminating crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Additionally, the successful detection of simulated magnetocardiography signals demonstrates the practical potential of this method.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes
Accurate magnetic source reconstruction critically depends on high-sensitivity multi-axis measurements. Given the superior sensitivity provided by the spin-exchange relaxation-free (SERF) regime, the development of high-sensitivity multi-axis atomic magnetometers (AMs) based on SERF is of paramount importance. However, most existing multi-axis AMs rely on multiple high-frequency modulated magnetic fields, increasing the spin-exchange relaxation and leading to the complex crosstalk between nearby magnetometers in array applications, thus limiting the measurement performance. In this study, we propose a method for magnetic field measurement with tunable sensitive axes, based on all-optical dual-axis measurements. This method adjusts the direction of atomic spin precession by applying a bias magnetic field. It allows for flexible switching between the transverse dual-axis and longitudinal axis as needed, without introducing complex multi-axis modulated magnetic fields. Experimental results demonstrate transverse dual-axis sensitivities are 3 fT/Hz1/2 for the x-axis and 2 fT/Hz1/2 for the y-axis, while the longitudinal sensitivity for the z-axis is 6 fT/Hz1/2 after switching the sensitive axis. Our approach offers significant advantages over existing methods, particularly in eliminating crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Additionally, the successful detection of simulated magnetocardiography signals demonstrates the practical potential of this method.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Full-frequency-range Cross-axis Decoupling for Dual-axis SERF Magnetometer Based on Amplitude-phase Characteristics
Compared to single axis measurement, multi-axis spin-exchange relaxation-free (SERF) atomic magnetometer has shown its superiorities in bio-magnetic measurement recently. However, in multi-axis measurement, cross-axis coupling error can introduce undesired output in the response signals, which varies with frequency and will have an adverse effect on measurement accuracy. To effectively suppress this error, we propose a full-frequency-range dual-axis cross-axis decoupling method based on amplitude-phase characteristics for dual-beam magnetometer. We analyze and measure the cross-axis coupling effect under different residual magnetic fields along the z-axis, and demonstrated that the residual magnetic field along the zaxis has great impact on the cross-axis coupling. Although the cross-axis coupling can be minimized by adjusting the residual magnetic field along the z-axis to zero, the cross-axis coupling still remains. Therefore, we establish the input-output equation in matrix form and derive the complex transform matrix based on amplitude-phase characteristics. Then we utilize the corresponding solving matrix to calculate the decoupling measurement results from the response signals under different cases of magnetic fields. Our method can realize a dual-axis complete decoupling measurement within full-frequency-range and provides a comprehensive description of the magnetic fields to be measured, including amplitude and phase information. The validity and effectiveness of our decoupling method is verified and it is demonstrated that our method can markedly enhance the measurement accuracy. We can realize the measurement error of the magnetic field phase difference lower than 1°, the relative measurement error of the magnetic field amplitude along the x-axis lower than 0.23% and that along the y-axis lower than 0.02%. Moreover, this method can be extended to any linear multi-axis measurement system.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Full-frequency-range Cross-axis Decoupling for Dual-axis SERF Magnetometer Based on Amplitude-phase Characteristics
Compared to single axis measurement, multi-axis spin-exchange relaxation-free (SERF) atomic magnetometer has shown its superiorities in bio-magnetic measurement recently. However, in multi-axis measurement, cross-axis coupling error can introduce undesired output in the response signals, which varies with frequency and will have an adverse effect on measurement accuracy. To effectively suppress this error, we propose a full-frequency-range dual-axis cross-axis decoupling method based on amplitude-phase characteristics for dual-beam magnetometer. We analyze and measure the cross-axis coupling effect under different residual magnetic fields along the z-axis, and demonstrated that the residual magnetic field along the zaxis has great impact on the cross-axis coupling. Although the cross-axis coupling can be minimized by adjusting the residual magnetic field along the z-axis to zero, the cross-axis coupling still remains. Therefore, we establish the input-output equation in matrix form and derive the complex transform matrix based on amplitude-phase characteristics. Then we utilize the corresponding solving matrix to calculate the decoupling measurement results from the response signals under different cases of magnetic fields. Our method can realize a dual-axis complete decoupling measurement within full-frequency-range and provides a comprehensive description of the magnetic fields to be measured, including amplitude and phase information. The validity and effectiveness of our decoupling method is verified and it is demonstrated that our method can markedly enhance the measurement accuracy. We can realize the measurement error of the magnetic field phase difference lower than 1°, the relative measurement error of the magnetic field amplitude along the x-axis lower than 0.23% and that along the y-axis lower than 0.02%. Moreover, this method can be extended to any linear multi-axis measurement system.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Neural Network-Assisted Magnetic Moment Measurement Using an Atomic Magnetometer
Accurate measurement of magnetization is crucial in paleomagnetism, paleontology, and materials science. This study proposes a novel approach for quantifying magnetization based on an atomic magnetometer. First, a hybrid model that combines the analytical and magnetic dipole models is established to represent the magnetic source. The spatially varying magnetic field induced by sample scanning is measured at specific positions using a spin-exchange relaxation-free (SERF) atomic magnetometer. This enables the extraction of the magnetic moment information from the source through a nonlinear fitting for an accurate calculation of magnetization. We incorporating the Bayesian Optimization Long- and Short-term Time-series Network (BO-LSTNet) model to efficiently learn from a limited number of measurement outcomes. By jointly optimizing the accuracy and dynamic range of magnetic moment measurement, the model can quickly determine the optimal measurement position for magnetic sources of different sizes. This method achieves the highest measurement accuracy while ensuring the dynamic range of magnetic moment measurement. Our results demonstrate a static sensitivity of 1.6×10-6 emu, a dynamic sensitivity of 1.9×10-7 emu/Hz1/2@20-80Hz, and a dynamic range of up to 6.6×10-4 emu. By employing the proposed method, limited measurement data are effectively utilized to automatically determine optimal measurement positions for coils of various sizes. Experimental results show that this approach reduces the relative measurement error from 20% to below 7%. The study introduces a neural network-based optimization framework for measurement parameters, significantly improving both efficiency and accuracy. Future work will aim to further enhance sensitivity and extend the approach to triaxial magnetic moment measurements.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Neural Network-Assisted Magnetic Moment Measurement Using an Atomic Magnetometer
Accurate measurement of magnetization is crucial in paleomagnetism, paleontology, and materials science. This study proposes a novel approach for quantifying magnetization based on an atomic magnetometer. First, a hybrid model that combines the analytical and magnetic dipole models is established to represent the magnetic source. The spatially varying magnetic field induced by sample scanning is measured at specific positions using a spin-exchange relaxation-free (SERF) atomic magnetometer. This enables the extraction of the magnetic moment information from the source through a nonlinear fitting for an accurate calculation of magnetization. We incorporating the Bayesian Optimization Long- and Short-term Time-series Network (BO-LSTNet) model to efficiently learn from a limited number of measurement outcomes. By jointly optimizing the accuracy and dynamic range of magnetic moment measurement, the model can quickly determine the optimal measurement position for magnetic sources of different sizes. This method achieves the highest measurement accuracy while ensuring the dynamic range of magnetic moment measurement. Our results demonstrate a static sensitivity of 1.6×10-6 emu, a dynamic sensitivity of 1.9×10-7 emu/Hz1/2@20-80Hz, and a dynamic range of up to 6.6×10-4 emu. By employing the proposed method, limited measurement data are effectively utilized to automatically determine optimal measurement positions for coils of various sizes. Experimental results show that this approach reduces the relative measurement error from 20% to below 7%. The study introduces a neural network-based optimization framework for measurement parameters, significantly improving both efficiency and accuracy. Future work will aim to further enhance sensitivity and extend the approach to triaxial magnetic moment measurements.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (22) , 36617-36626
A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer
Spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultra-high sensitivity in ultra-weak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF atomic magnetometer, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz 1/2 in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (22) , 36617-36626
A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer
Spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultra-high sensitivity in ultra-weak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF atomic magnetometer, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz 1/2 in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.
- 17 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (25)
Femtotesla all-optical dual-axis spin-exchange relaxation-free magnetometer
The sensitivity of existing all-optical atomic magnetometers is significantly compromised due to the simultaneous influence of optical parameters on both optical pumping and optical modulation of atoms. The tight interlinkage of these processes poses challenges for their individual optimization, thereby restricting the achievable sensitivity. To address this issue, we developed a comprehensive optical modulation analytical model that fully considers the effects of dynamic optical pumping. Building upon this model, we introduced a multi-objective optimization method for optical parameters, leading to minimal non-sensitive axis crosstalk and optimal sensitivity. Experimental results demonstrated a femtotesla all-optical spin-exchange relaxation-free magnetometer with sensitivities of 2 fT/Hz1/2 along the y-axis and 4 fT/Hz1/2 along the x-axis, respectively. This advancement surpasses the sensitivity of existing optically modulated magnetometers and bears profound implications for the advancement and application of arrayed magnetometers.
- 17 June 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (25)
Femtotesla all-optical dual-axis spin-exchange relaxation-free magnetometer
The sensitivity of existing all-optical atomic magnetometers is significantly compromised due to the simultaneous influence of optical parameters on both optical pumping and optical modulation of atoms. The tight interlinkage of these processes poses challenges for their individual optimization, thereby restricting the achievable sensitivity. To address this issue, we developed a comprehensive optical modulation analytical model that fully considers the effects of dynamic optical pumping. Building upon this model, we introduced a multi-objective optimization method for optical parameters, leading to minimal non-sensitive axis crosstalk and optimal sensitivity. Experimental results demonstrated a femtotesla all-optical spin-exchange relaxation-free magnetometer with sensitivities of 2 fT/Hz1/2 along the y-axis and 4 fT/Hz1/2 along the x-axis, respectively. This advancement surpasses the sensitivity of existing optically modulated magnetometers and bears profound implications for the advancement and application of arrayed magnetometers.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optical Parameter Decoupling and Optimization for Elliptically Polarized Atomic Magnetometer
Elliptically polarized atomic magnetometers (AMs) offer high sensitivity and compactness by using a single laser beam to polarize atoms and detect optical rotation angles. However, their sensitivity advantage over optical absorption-based AMs has not been sufficiently demonstrated. This is because the optical parameters significantly affect the pumping and probing processes, leading to parameter coupling when both processes are optimized simultaneously. Such coupling presents a considerable challenge for achieving simultaneous parameter optimization, ultimately limiting the achievable sensitivity. In this study, we developed a modified input-output model for a magnetometer, based on which an optical parameter decoupling and optimization method is proposed. Our method enables us to obtain the optimal optical parameters simultaneously, including the ellipticity, intensity, and frequency of light. Consequently, a sensitivity of 6 fT/Hz 1/2 was achieved using a 4 × 4 × 4 mm 3 87 Rb vapor cell (effective volume of 0.027 cm 3 ). This work offers an efficient strategy to achieve higher sensitivity using single-beam miniaturized AMs, contributing significantly to promote biomagnetism research.
- 18 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Optical Parameter Decoupling and Optimization for Elliptically Polarized Atomic Magnetometer
Elliptically polarized atomic magnetometers (AMs) offer high sensitivity and compactness by using a single laser beam to polarize atoms and detect optical rotation angles. However, their sensitivity advantage over optical absorption-based AMs has not been sufficiently demonstrated. This is because the optical parameters significantly affect the pumping and probing processes, leading to parameter coupling when both processes are optimized simultaneously. Such coupling presents a considerable challenge for achieving simultaneous parameter optimization, ultimately limiting the achievable sensitivity. In this study, we developed a modified input-output model for a magnetometer, based on which an optical parameter decoupling and optimization method is proposed. Our method enables us to obtain the optimal optical parameters simultaneously, including the ellipticity, intensity, and frequency of light. Consequently, a sensitivity of 6 fT/Hz 1/2 was achieved using a 4 × 4 × 4 mm 3 87 Rb vapor cell (effective volume of 0.027 cm 3 ). This work offers an efficient strategy to achieve higher sensitivity using single-beam miniaturized AMs, contributing significantly to promote biomagnetism research.
- Open Access
Analysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer
Three-axis atomic magnetometers have an excellent advantage for determining the complete vector information of a magnetic field to be measured. However, the crosstalk effect, which leads to an error output on one axis owing to a magnetic field on the other axes, can reduce the measurement accuracy. In this study, we propose an effective suppression method for the crosstalk effect in a three-axis atomic magnetometer. First, we investigated and analyzed the main factors that introduce the effect. Based on this, the modulation parameters were optimized to improve the scale factors, which obtained a coupling coefficient of less than 6% for the atomic magnetometer. Subsequently, the associated transfer matrix was corrected to further suppress the crosstalk effect. After correction, all the coupling coefficients were decreased to less than 3%, with the majority being lower than 1%.
Open AccessAnalysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer
Three-axis atomic magnetometers have an excellent advantage for determining the complete vector information of a magnetic field to be measured. However, the crosstalk effect, which leads to an error output on one axis owing to a magnetic field on the other axes, can reduce the measurement accuracy. In this study, we propose an effective suppression method for the crosstalk effect in a three-axis atomic magnetometer. First, we investigated and analyzed the main factors that introduce the effect. Based on this, the modulation parameters were optimized to improve the scale factors, which obtained a coupling coefficient of less than 6% for the atomic magnetometer. Subsequently, the associated transfer matrix was corrected to further suppress the crosstalk effect. After correction, all the coupling coefficients were decreased to less than 3%, with the majority being lower than 1%.