XLXiaoyu Li

Xiaoyu Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoyu Li has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Response Model of Naturally Abundant Rubidium SERF Magnetomete

    by Jianwei Sheng, Xiaoyu Li, Ziao Liu, Zhongyu Wang, Shushan Gao, Jixi Lu

    Spin-exchange relaxation-free (SERF) atomic magnetometers are widely utilized due to high sensitivity and promising miniaturization capability. Alkali vapor cells filled with 87Rb are commonly employed as the core component, while facing challenges of high cost and difficulty in scalable production. Replacing 87Rb with naturally abundant rubidium (natRb) in vapor cell fabrication can substantially reduce the cost of isotopic enrichment. In this study, we conduct comparative analyses of rubidium isotopes and determine that the gyromagnetic ratio difference between natRb and 87Rb arises from their distinct nuclear spins, which results in the polarization-dependent slowing-down phenomenon. Under the SERF regime, a hybrid slowing-down factor of the natRb ensemble is formulated based on equilibrium mass-dependent isotopic fractionation theory. We then analyze relaxation rate differences between ${}^{\text{nat}}$ Rb and 87Rb vapor cells and ultimately establish the response model of the ${}^{\text{nat}}$ Rb SERF magnetometer. The result demonstrates that optimizing the buffer gas pressure allows the ${}^{\text{nat}}$ Rb magnetometer to achieve a response signal close to that of the 87Rb device, enabling comparable sensitivity. Experiments conducted using 8 mm cubic vapor cells as a representative case revealed that the response signal of the ${}^{\text{nat}}$ Rb magnetometer was approximately only 19% lower than that of the 87Rb device, with a comparable increase in probe noise. This led to a slight yet engineering-tolerable difference in sensitivity. These results indicate that ${}^{\text{nat}}$ Rb provides a practical and cost-effective alternative to 87Rb in high-sensitivity applications. The presented model can be extended to arbitrary cell sizes and other alkali species.


  • Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

    by Shushan Gao, Xiaoyu Li, Jianwei Sheng, Zhongyu Wang, Guangmao Xu, Zeyu Wang, Bangcheng Han, Jixi Lu

  • Polarization-dynamics model of triaxial modulation in spin-exchange-relaxation-free atomic magnetometers

    by Ziao Liu, Jianli Li, Xiaoyu Li, Jianwei Sheng, Zhongyu Wang, Shushan Gao, Jixi Lu


  • Deep Reinforcement Learning Assisted Triaxial Magnetic Moment Vector Measurement Using an Atomic Magnetometer

    by Zhongyu Wang, Min Zhang, Xiaoyu Li, Jianwei Sheng, Shushan Gao, Huafeng Qin, Jixi Lu

    Accurately measuring the triaxial magnetic moment vector of paleomagnetic samples is crucial for geological research. Atomic magnetometers possess extremely high sensitivity for magnetic field measurements; however, achieving high-precision triaxial magnetic moment vector measurements remains challenging. This difficulty primarily arises from the strong dependence of measurement accuracy on the relative positioning between the sensor and the sample, which is difficult to determine in advance. To address this issue, we propose a measurement approach based on deep reinforcement learning (DRL) to dynamically optimize the measurement distance. Specifically, we introduce a Dueling Deep Transformer Q-Network (Dueling DTQN) algorithm, which treats the atomic magnetometer as an agent interacting with the magnetic field environment to autonomously determine optimal measurement positions. We constructed a measurement system using a spin-exchange relaxation-free (SERF) atomic magnetometer and validated the proposed method on paleomagnetic samples. Experimental results demonstrated high measurement sensitivity of 7.8×10-6, 8.6×10-6, and 4.2×10-6 emu along the x, y, and z axes, respectively, and strong consistency with results obtained from a superconducting rock magnetometer (SRM). This work highlights the novel application of DRL in magnetic moment measurement, offering an efficient and intelligent measurement in paleomagnetism and materials analysis.


  • Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes

    by Xiaoyu Li, Bangcheng Han, Ziao Liu, Zhongyu Wang, Jianwei Sheng, Shushan Gao, Jixi Lu

    Accurate magnetic source reconstruction critically depends on high-sensitivity multi-axis measurements. Given the superior sensitivity provided by the spin-exchange relaxation-free (SERF) regime, the development of high-sensitivity multi-axis atomic magnetometers (AMs) based on SERF is of paramount importance. However, most existing multi-axis AMs rely on multiple high-frequency modulated magnetic fields, increasing the spin-exchange relaxation and leading to the complex crosstalk between nearby magnetometers in array applications, thus limiting the measurement performance. In this study, we propose a method for magnetic field measurement with tunable sensitive axes, based on all-optical dual-axis measurements. This method adjusts the direction of atomic spin precession by applying a bias magnetic field. It allows for flexible switching between the transverse dual-axis and longitudinal axis as needed, without introducing complex multi-axis modulated magnetic fields. Experimental results demonstrate transverse dual-axis sensitivities are 3 fT/Hz1/2 for the x-axis and 2 fT/Hz1/2 for the y-axis, while the longitudinal sensitivity for the z-axis is 6 fT/Hz1/2 after switching the sensitive axis. Our approach offers significant advantages over existing methods, particularly in eliminating crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Additionally, the successful detection of simulated magnetocardiography signals demonstrates the practical potential of this method.


  • Neural Network-Assisted Magnetic Moment Measurement Using an Atomic Magnetometer

    by Zhongyu Wang, Jixi Lu, Ziao Liu, Xiaoyu Li, Jianwei Sheng, Jianli Li

    Accurate measurement of magnetization is crucial in paleomagnetism, paleontology, and materials science. This study proposes a novel approach for quantifying magnetization based on an atomic magnetometer. First, a hybrid model that combines the analytical and magnetic dipole models is established to represent the magnetic source. The spatially varying magnetic field induced by sample scanning is measured at specific positions using a spin-exchange relaxation-free (SERF) atomic magnetometer. This enables the extraction of the magnetic moment information from the source through a nonlinear fitting for an accurate calculation of magnetization. We incorporating the Bayesian Optimization Long- and Short-term Time-series Network (BO-LSTNet) model to efficiently learn from a limited number of measurement outcomes. By jointly optimizing the accuracy and dynamic range of magnetic moment measurement, the model can quickly determine the optimal measurement position for magnetic sources of different sizes. This method achieves the highest measurement accuracy while ensuring the dynamic range of magnetic moment measurement. Our results demonstrate a static sensitivity of 1.6×10-6 emu, a dynamic sensitivity of 1.9×10-7 emu/Hz1/2@20-80Hz, and a dynamic range of up to 6.6×10-4 emu. By employing the proposed method, limited measurement data are effectively utilized to automatically determine optimal measurement positions for coils of various sizes. Experimental results show that this approach reduces the relative measurement error from 20% to below 7%. The study introduces a neural network-based optimization framework for measurement parameters, significantly improving both efficiency and accuracy. Future work will aim to further enhance sensitivity and extend the approach to triaxial magnetic moment measurements.


  • A Performance-Enhanced Closed-Loop SERF Atomic Magnetometer

    by Ziao Liu, Jianli Li, Xiaoyu Li, Zhongyu Wang, Jianwei Sheng, Jixi Lu

    Spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) exhibit ultra-high sensitivity in ultra-weak magnetic field measurement, but their narrow bandwidth constrains the scope of their applications. To increase the bandwidth, magnetic field closed-loop control technology has been introduced into AMs with demonstrated efficacy. However, previous research on closed-loop AMs resulted in signal distortion problems, primarily due to imprecise closed-loop models and control parameters selection without theoretical support. This problem is specifically characterized by the unexpected amplification or reduction of signals at certain frequencies, directly leading to the degradation of the frequency performance of the closed-loop AM, making it unsuitable for applications requiring full-bandwidth measurement. In this study, we proposed a performance-enhanced closed-loop SERF atomic magnetometer, maximizing the bandwidth while ensuring consistent performance across the entire bandwidth. An accurate closed-loop system model was first established. Subsequently, an optimal relationship between the control parameters was proposed according to the eigenvalues of the closed-loop system, and the particle swarm optimization (PSO) algorithm was introduced to determine the optimal control parameters. The improved closed-loop system was constructed in a triaxial SERF AM, achieving an average bandwidth of 410 Hz and a sensitivity of 10 fT/Hz 1/2 in three axes, while ensuring consistent performance across the entire bandwidth. With the proposed method, the optimized control parameters can be obtained only by requiring the frequency response of the open-loop AM, which is convenient and useful for closed-loop AM applications.


  • Femtotesla all-optical dual-axis spin-exchange relaxation-free magnetometer

    by Xiaoyu Li, Bangcheng Han, Ziao Liu, Zhongyu Wang, Jianwei Sheng, Min Xiang, Jixi Lu

    The sensitivity of existing all-optical atomic magnetometers is significantly compromised due to the simultaneous influence of optical parameters on both optical pumping and optical modulation of atoms. The tight interlinkage of these processes poses challenges for their individual optimization, thereby restricting the achievable sensitivity. To address this issue, we developed a comprehensive optical modulation analytical model that fully considers the effects of dynamic optical pumping. Building upon this model, we introduced a multi-objective optimization method for optical parameters, leading to minimal non-sensitive axis crosstalk and optimal sensitivity. Experimental results demonstrated a femtotesla all-optical spin-exchange relaxation-free magnetometer with sensitivities of 2 fT/Hz1/2 along the y-axis and 4 fT/Hz1/2 along the x-axis, respectively. This advancement surpasses the sensitivity of existing optically modulated magnetometers and bears profound implications for the advancement and application of arrayed magnetometers.