Karoline-Marie Bornemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karoline-Marie Bornemann has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dominik Obrist
University of Bern
6 shared publications - Silje Ekroll Jahren
ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
2 shared publications - Ardeshir Hanifi
KTH Royal Institute of Technology
1 shared publication - Caglayan Demirel
Department of Internal Medicine II, Division of Cardiology, Medical University of Vienna, 1090 Vienna, Austria
1 shared publication - Dan S. Henningson
KTH Royal Institute of Technology
1 shared publication - Mohammad Moniripiri
KTH Royal Institute of Technology
1 shared publication
Latest Publications
- Open Access
- 25 March 2026
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 1031
Optimal three-dimensional perturbations in fluttering and non-fluttering bioprosthetic aortic valves
This study examines the transition to turbulence downstream of fluttering and non-fluttering bioprosthetic aortic valves using global linear stability theory. During systole, increasing inflow velocities result in temporally evolving flow profiles downstream of the valve which are highly influenced by the leaflet kinematics. These profiles are time averaged at the sinotubular junction over successive windows and used as boundary conditions to obtain base flows for stability analysis. Three-dimensional global modes are computed for one design of each valve type across multiple time windows, revealing several unstable modes whose frequencies and growth rates increase over time. Notably, the non-fluttering valve exhibits higher growth rates than the fluttering valve. The resulting eigenspectra show that, for each case, the most unstable eigenvalues align along two distinct parabolic branches in the complex plane. For each valve case, the modes within each branch are found to have similar group velocities, suggesting that the unstable modes along a branch constitute a coherent structure. Motivated by this, a transient growth analysis is conducted to identify the optimal initial perturbations that maximise energy gain for a given time horizon. When superimposed onto the base flow, these perturbations generate vortical structures that closely resemble those observed in fully coupled nonlinear fluid–structure interaction simulations for a similar time scale as the one used to obtain the optimal perturbations. These results suggest that the optimal perturbations may initiate the shear-layer instabilities responsible for transition to turbulence, providing valuable insight into the underlying mechanisms in the flow fields downstream of bioprosthetic valve designs.
- 25 March 2026
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 1031
Open AccessOptimal three-dimensional perturbations in fluttering and non-fluttering bioprosthetic aortic valves
This study examines the transition to turbulence downstream of fluttering and non-fluttering bioprosthetic aortic valves using global linear stability theory. During systole, increasing inflow velocities result in temporally evolving flow profiles downstream of the valve which are highly influenced by the leaflet kinematics. These profiles are time averaged at the sinotubular junction over successive windows and used as boundary conditions to obtain base flows for stability analysis. Three-dimensional global modes are computed for one design of each valve type across multiple time windows, revealing several unstable modes whose frequencies and growth rates increase over time. Notably, the non-fluttering valve exhibits higher growth rates than the fluttering valve. The resulting eigenspectra show that, for each case, the most unstable eigenvalues align along two distinct parabolic branches in the complex plane. For each valve case, the modes within each branch are found to have similar group velocities, suggesting that the unstable modes along a branch constitute a coherent structure. Motivated by this, a transient growth analysis is conducted to identify the optimal initial perturbations that maximise energy gain for a given time horizon. When superimposed onto the base flow, these perturbations generate vortical structures that closely resemble those observed in fully coupled nonlinear fluid–structure interaction simulations for a similar time scale as the one used to obtain the optimal perturbations. These results suggest that the optimal perturbations may initiate the shear-layer instabilities responsible for transition to turbulence, providing valuable insight into the underlying mechanisms in the flow fields downstream of bioprosthetic valve designs.
- Open Access
- 20 November 2025
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 10 (11)
Transition to turbulence past bioprosthetic aortic valves
This paper is associated with a video winner of a 2024 American Physical Society's Division of Fluid Dynamics (DFD) Gallery of Fluid Motion Award for work presented at the DFD Gallery of Fluid Motion. The original video is available online at the Gallery of Fluid Motion, .
- 20 November 2025
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 10 (11)
Open AccessTransition to turbulence past bioprosthetic aortic valves
This paper is associated with a video winner of a 2024 American Physical Society's Division of Fluid Dynamics (DFD) Gallery of Fluid Motion Award for work presented at the DFD Gallery of Fluid Motion. The original video is available online at the Gallery of Fluid Motion, .
- Open Access
- 1 May 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (5)
Leaflet fluttering changes laminar–turbulent transition mechanisms past bioprosthetic aortic valves
Bioprosthetic heart valves (BHV) are implantable devices for aortic valve replacement in patients with moderate to severe aortic stenosis. BHV create turbulent flow during peak systole, potentially causing adverse effects and contributing to their limited durability of 10–15 years. Although a deeper understanding of turbulence is important for valve design optimization, laminar–turbulent transition mechanisms past BHV are still poorly understood. This study performs high-fidelity fluid–structure interaction simulations for generic aortic geometries with BHV to assess how leaflet fluttering changes laminar–turbulent transition mechanisms. During the opening of BHV, a three-lobed vortex ring is formed. The interaction between this starting vortex, counter-rotating streamwise vortices created above the valve posts and periodically shed vortex rings due to leaflet fluttering leads to the nonlinear breakdown to small-scale vortices in the ascending aorta. The absence of fluttering alters vortex formation fundamentally and results in lower turbulence levels. Modal analysis shows that the laminar–turbulent transition in a non-fluttering valve is governed by the dynamics of an azimuthal mode of wavenumber 6, whereas the fluttering motion promotes a mode of wavenumber 3 and suppresses higher modes. Establishing such relations between fundamental mechanisms of laminar–turbulent transition may contribute to optimized valve design capable of controlling transition to turbulence.
- 1 May 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (5)
Open AccessLeaflet fluttering changes laminar–turbulent transition mechanisms past bioprosthetic aortic valves
Bioprosthetic heart valves (BHV) are implantable devices for aortic valve replacement in patients with moderate to severe aortic stenosis. BHV create turbulent flow during peak systole, potentially causing adverse effects and contributing to their limited durability of 10–15 years. Although a deeper understanding of turbulence is important for valve design optimization, laminar–turbulent transition mechanisms past BHV are still poorly understood. This study performs high-fidelity fluid–structure interaction simulations for generic aortic geometries with BHV to assess how leaflet fluttering changes laminar–turbulent transition mechanisms. During the opening of BHV, a three-lobed vortex ring is formed. The interaction between this starting vortex, counter-rotating streamwise vortices created above the valve posts and periodically shed vortex rings due to leaflet fluttering leads to the nonlinear breakdown to small-scale vortices in the ascending aorta. The absence of fluttering alters vortex formation fundamentally and results in lower turbulence levels. Modal analysis shows that the laminar–turbulent transition in a non-fluttering valve is governed by the dynamics of an azimuthal mode of wavenumber 6, whereas the fluttering motion promotes a mode of wavenumber 3 and suppresses higher modes. Establishing such relations between fundamental mechanisms of laminar–turbulent transition may contribute to optimized valve design capable of controlling transition to turbulence.
- Open Access
- 25 April 2024
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 985, A41
Instability mechanisms initiating laminar–turbulent transition past bioprosthetic aortic valves
Bioprosthetic heart valves create turbulent flow during early systole which might be detrimental to their durability and performance. Complex mechanisms in the unsteady and heterogeneous flow field complicate the isolation of specific instability mechanisms. We use linear stability analysis and numerical simulations of the flow in a simplified model to study mechanisms initiating the laminar–turbulent transition. The analysis of a modified Orr–Sommerfeld equation, which includes a model for fluid–structure interaction (FSI), indicates Kelvin–Helmholtz and FSI instabilities for a physiological Reynolds number regime. Two-dimensional parametrized FSI simulations confirm the growth rates and phase speeds of these instabilities. The eigenmodes associated with the observed leaflet kinematics allow for decoupled leaflet oscillations. A detailed analysis of the temporal evolution of the flow field shows that the starting vortex interacts with the aortic wall leading to a secondary vortex which moves towards the shear layer in the wake of the leaflets. This appears to be connected to the onset of the shear layer instabilities that are followed by the onset of leaflet motion leading to large-scale vortex shedding and eventually to a nonlinear breakdown of the flow. Numerical results further indicate that a narrower aorta leads to an earlier onset of the shear layer instabilities. They also suggest that the growing perturbations of the shear layer instability propagate upstream and may initiate the FSI instabilities on the valve leaflets.
- 25 April 2024
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 985, A41
Open AccessInstability mechanisms initiating laminar–turbulent transition past bioprosthetic aortic valves
Bioprosthetic heart valves create turbulent flow during early systole which might be detrimental to their durability and performance. Complex mechanisms in the unsteady and heterogeneous flow field complicate the isolation of specific instability mechanisms. We use linear stability analysis and numerical simulations of the flow in a simplified model to study mechanisms initiating the laminar–turbulent transition. The analysis of a modified Orr–Sommerfeld equation, which includes a model for fluid–structure interaction (FSI), indicates Kelvin–Helmholtz and FSI instabilities for a physiological Reynolds number regime. Two-dimensional parametrized FSI simulations confirm the growth rates and phase speeds of these instabilities. The eigenmodes associated with the observed leaflet kinematics allow for decoupled leaflet oscillations. A detailed analysis of the temporal evolution of the flow field shows that the starting vortex interacts with the aortic wall leading to a secondary vortex which moves towards the shear layer in the wake of the leaflets. This appears to be connected to the onset of the shear layer instabilities that are followed by the onset of leaflet motion leading to large-scale vortex shedding and eventually to a nonlinear breakdown of the flow. Numerical results further indicate that a narrower aorta leads to an earlier onset of the shear layer instabilities. They also suggest that the growing perturbations of the shear layer instability propagate upstream and may initiate the FSI instabilities on the valve leaflets.
- Open Access
- 1 December 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (4) , 046120
Altered blood flow due to larger aortic diameters in patients with transcatheter heart valve thrombosis
The etiology of transcatheter heart valve thrombosis (THVT) and the relevance of the aortic root geometry on the occurrence of THVT are largely unknown. The first aim of this pilot study is to identify differences in aortic root geometry between THVT patients and patients without THVT after transcatheter aortic valve implantation (TAVI). Second, we aim to investigate how the observed difference in aortic diameters affects the aortic flow using idealized computational geometric models. Aortic dimension was assessed using pre-TAVI multi-detector computed tomography scans of eight patients with clinical apparent THVT and 16 unaffected patients (two for each THVT patient with same valve type and size) from the Bern-TAVI registry. Among patients with THVT the right coronary artery height was lower (−40%), and sinotubular junction (STJ) and ascending aorta (AAo) diameters tended to be larger (9% and 14%, respectively) compared to the unaffected patients. Fluid–structure interaction (FSI) in two idealized aortic models with the observed differences in STJ and AAo diameter showed higher backflow rate at the STJ (+16%), lower velocity magnitudes in the sinus (−5%), and higher systolic turbulent dissipation rate in the AAo (+8%) in the model with larger STJ and AAo diameters. This pilot study suggests a direct effect of the aortic dimensions on clinically apparent THVT. The FSI study indicates that larger STJ and AAo diameters potentially favor thrombus formation by increased backflow rate and reduced wash-out efficiency of the sinus. The reported observations require clinical validation but could potentially help identifying patients at risk for THVT.
- 1 December 2023
- Published by AIP Publishing in APL Bioengineering
- Vol. 7 (4) , 046120
Open AccessAltered blood flow due to larger aortic diameters in patients with transcatheter heart valve thrombosis
The etiology of transcatheter heart valve thrombosis (THVT) and the relevance of the aortic root geometry on the occurrence of THVT are largely unknown. The first aim of this pilot study is to identify differences in aortic root geometry between THVT patients and patients without THVT after transcatheter aortic valve implantation (TAVI). Second, we aim to investigate how the observed difference in aortic diameters affects the aortic flow using idealized computational geometric models. Aortic dimension was assessed using pre-TAVI multi-detector computed tomography scans of eight patients with clinical apparent THVT and 16 unaffected patients (two for each THVT patient with same valve type and size) from the Bern-TAVI registry. Among patients with THVT the right coronary artery height was lower (−40%), and sinotubular junction (STJ) and ascending aorta (AAo) diameters tended to be larger (9% and 14%, respectively) compared to the unaffected patients. Fluid–structure interaction (FSI) in two idealized aortic models with the observed differences in STJ and AAo diameter showed higher backflow rate at the STJ (+16%), lower velocity magnitudes in the sinus (−5%), and higher systolic turbulent dissipation rate in the AAo (+8%) in the model with larger STJ and AAo diameters. This pilot study suggests a direct effect of the aortic dimensions on clinically apparent THVT. The FSI study indicates that larger STJ and AAo diameters potentially favor thrombus formation by increased backflow rate and reduced wash-out efficiency of the sinus. The reported observations require clinical validation but could potentially help identifying patients at risk for THVT.