JAJoseba Arza

Joseba Arza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseba Arza has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Explicit Stability Assessment of High-Power Inverter With Model Predictive Control in Offshore Wind Farm

    by Pedro Catalán, Yanbo Wang, Carlos Ruiz, Joseba Arza, Gonzalo Abad, Zhe Chen

    The high-power grid-connected inverter (GCI) plays a key role in integrating wind power generation. The finite control set model predictive control (FCS-MPC) has emerged as a promising high-performance control strategy for this class of power converters. However, practical stability assessment of GCI with MPC has not been fully addressed. This article investigates the stability of high-power GCI controlled by MPC and its application in offshore wind farm. The frequency scan technique is employed to derive the impedance characteristic of MPC-enabled inverter. Then, effects of MPC parameters and operating conditions on passivity are investigated. The proposed control strategy is validated and compared with classical PI-based control within Alpha Ventus offshore wind farm. Simulation and hardware-in-the-loop (HiL) verification are both implemented. The employed HiL setup integrates dSPACE DS1006 and PLECS RT Box 1, providing a versatile real-time testing platform for independent validation of the controller and plant model. The study findings show that MPC strategy can effectively mitigate oscillation phenomena and enhance stability of offshore wind farm under weak grid conditions. Hence, the proposed MPC strategy is a promising solution to promote penetration of offshore wind power generation into power system

  • Open Access

    Hardware-in-the-Loop Platform for Virtual Certification of Traction Systems for Railway

    by Mikel Manzanal Herrero, Aitor Rodríguez Mendez, Iraitz Carretero Caballo, Iker Muniategui Aspiazu, Joseba Arza

    The railway industry is continuously evolving, necessitating the development of more intricate and dependable software algorithms. To meet these requirements, the creation of new validation tools has become increasingly crucial, with a specific focus on Hardware-In-the-Loop (HIL) simulations. HIL simulations are invaluable during the product development process as they improve system resilience, performance, and overall product value. This study details the design of a HIL platform that can validate the software created for the Traction Control Unit (TCU) of a complex traction system. By producing real interfaces in real-time, this platform offers a practical simulation environment for examining the TCU software. The HIL platform built in this research provides comprehensive test coverage of the TCU software, a feat that is often unattainable through on-train testing. Moreover, the platform provides greater tuning and debugging capabilities, allowing for a virtual certification of the TCU software, which can offer greater security and assurances of success when encountering official tests. Thus, this paper demonstrates how profitable a HIL platform that models the whole traction system can be in order to debug and certificate its TCU software.


  • Advanced Fault Ride-Through Operation Strategy Based on Model Predictive Control for High Power Wind Turbine

    by Pedro Catalán, Yanbo Wang, Joseba Arza, Zhe Chen

    This article presents an advanced fault ride-through control strategy based on model predictive control (MPC) of high-power wind turbine (WT), which is able to provide voltage support for power grid under symmetrical and asymmetrical grid faults. An optimal cost function is first established to realize multi-objective control of wind power converter, considering current regulation, neutral-point voltage balance, and switching frequency control. The flexible positive and negative sequence control (FPNSC) method is applied to generate the current references complying with converter current and voltage limitations. Simulation and hardware-in-the-loop experimental verification are implemented to validate the effectiveness of the proposed fault-ride through operation strategy. The verification results show that the proposed strategy is able to effectively support voltage and implement fault ride-through (FRT) during grid faults with optimized neutral-point voltage and average switching frequency. The proposed MPC strategy can address different fault conditions with good adaptivity. It thus enhances the operation performance of high-power WT during faults events.


  • Open Access

    Enhanced TVI for Grid Forming VSC under Unbalanced Faults

    by Markel Zubiaga, Carmen Cardozo, Thibault Prevost, Alain Sanchez-Ruiz, Eneko Olea, Pedro Izurza, Siam Hasan Khan, Joseba Arza

    With an increasing capacity of inverter-based generation and with a 100% renewable energy power system on the horizon, grid forming converters have the potential to become the prevalent control mode in the grid. Thus, the correct performance of these devices is going to be crucial for system stability and security of supply. Most research related to the grid-forming control is focused on normal operating conditions, although significant effort has been devoted to current limitation strategies to ensure Low Voltage Ride Through (LVRT) capability. However, most contributions usually consider only balanced faults. This paper, proposes a new current limiting method based on the well-known threshold virtual impedance (TVI) that keeps the voltage source behaviour associated to the grid forming (GFM) capability, even when the current limit is reached, while reducing the voltage unbalance according to user-defined settings.


  • Open Access

    Power Capability Boundaries for an Inverter Providing Multiple Grid Support Services

    by Markel Zubiaga, Alain Sanchez-Ruiz, Eneko Olea, Eneko Unamuno, Aitor Bilbao, Joseba Arza

    It is getting more common every day to install inverters that offer several grid support services in parallel. As these services are provided, a simultaneous need arises to know the combined limit of the inverter for those services. In the present paper, operational limits are addressed based on a utility scale for a real inverter scenario with an energy storage system (ESS) (1.5 MW). The paper begins by explaining how active and reactive power limits are calculated, illustrating the PQ maps depending on the converter rated current and voltage. Then, the effect of the negative sequence injection, the phase shift of compensated harmonics and the transformer de-rating are introduced step-by-step. Finally, inverter limits for active filter applications are summarized, to finally estimate active and reactive power limits along with the harmonic current injection for some example cases. The results show that while the phase shift of the injected negative sequence has a significant effect in the available inverter current, this is not the case for the phase shift of injected harmonics. However, the amplitude of the injected negative sequence and harmonics will directly impact the power capabilities of the inverter and therefore, depending on the grid-side voltage, it might be interesting to design an output transformer with a different de-rating factor to increase the power capabilities.


  • Simple and Affordable Method for Fast Transient Measurements of SiC Devices

    by David Garrido, Igor Baraia-Etxaburu, Joseba Arza, Manex Barrenetxea

    The measurement of fast voltage and current transients of SiC devices requires high bandwidth probes. Commercially available voltage and current probes can be expensive and in addition, the delay introduced by them must be compensated to achieve a proper time alignment (de-skew). Determining this de-skewing value is not a trivial task. In this paper, a simple and affordable measurement method is presented for the simultaneous measurement of the voltage and current transients of SiC devices. The voltage is measured by means of a high bandwidth RC attenuator while the current is estimated from the voltage drop in the stray inductance of the switching loop. Since both voltages are measured with two equal and matched high bandwidth passive voltage probes there is no need to apply any deskew. This is one of the most important advantages of the method. The presented method is experimentally evaluated and used for the estimation of energy switching losses in the tested SiC - MOSFET.


  • Open Access

    Frequency-Dependent Pi Model of a Three-Core Submarine Cable for Time and Frequency Domain Analysis

    by Carlos Ruiz, Gonzalo Abad, Markel Zubiaga, Danel Madariaga, Joseba Arza

    In this paper, a Frequency-Dependent Pi Model (FDPi) of a three-core submarine cable is presented. The model is intended to be used for the representation of submarine cables in an Offshore Wind Power Plant (OWPP) scenario for both time and frequency domain analysis. The frequency-dependent variation of each conductive layer is modeled by a Foster equivalent network whose parameters are tuned by means of Vector Fitting (VF) algorithm. The complete formulation for the parameterization of the model is presented in detail, which allows an easy reproduction of the presented model. The validation of the model is performed via a comparison with a well-established reference model, the Universal Line Model (ULM) from PSCAD/EMTDC software. Two cable system case studies are presented. The first case study shows the response of the FDPi Model for a three-core submarine cable. On the other hand, the second case study depicts the response of three single-core underground cables laying in trefoil formation. This last case shows the applicability of the FDPi Model to other types of cable systems and indirectly validates the response of the aforementioned model with experimental results. Additionally, potential applications of the FDPi model are presented.