Yun Zhao
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Yun Zhao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Yuxin Lu
Guangdong Provincial Key Laboratory of Intelligent Measurement and Advanced Metering of Power Grid, Electric Power Research Institute of CSG, Guangzhou, Guangdong, China
2 shared publications - Hongxuan Luo
Department of Instrumental and Electrical Engineering, Xiamen University, Xiamen, People’s Republic of China
1 shared publication - Jian Li
Metrology Center, Guangdong Power Grid Co., Ltd, China
1 shared publication - Jinfeng Yang
College of Land and Environment, Shenyang Agricultural University, Shenyang 110866, China
1 shared publication - Ke Zhang
Metrology Center, Guangdong Power Grid Co., Ltd, China
1 shared publication - Shuoyu Li
Power Supply Service, Dongguan Power Supply Bureau, China
1 shared publication
Latest Publications
- Open Access
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 265-271
Research on line loss anomaly identification method of distribution network considering distributed photovoltaic access
For a long time, the identification of 10kV distribution network line loss anomalies has been a very difficult task, with the large number of distributed photovoltaics (DPV) access, the distribution network power flow from one-way flow to two-way flow, which greatly affects the line power flow, voltage and network loss, and increases the difficulty of identifying abnormal distribution network line loss. Therefore, a method for identifying line loss anomalies in distribution network considering distributed photovoltaic access is proposed. Firstly, the characteristic index of distribution network line loss after distributed photovoltaic access is extracted, and the correlation between the line loss index and line loss of the distribution network is calculated by using the gray correlation analysis method, and the correlation degree is ranked. Then, according to the order of gray correlation degree, appropriate indicators are selected for fuzzy C-means clustering, and outliers in each category are detected based on the K-nearest neighbor algorithm to determine whether there is an abnormal line loss in the distribution network. Finally, the verification analysis is carried out through the example, and the results show that the proposed method can effectively identify whether abnormal line loss occurs in the distribution network containing distributed photovoltaics.
- 19 January 2024
- Published by Association for Computing Machinery (ACM)
- p. 265-271
Open AccessResearch on line loss anomaly identification method of distribution network considering distributed photovoltaic access
For a long time, the identification of 10kV distribution network line loss anomalies has been a very difficult task, with the large number of distributed photovoltaics (DPV) access, the distribution network power flow from one-way flow to two-way flow, which greatly affects the line power flow, voltage and network loss, and increases the difficulty of identifying abnormal distribution network line loss. Therefore, a method for identifying line loss anomalies in distribution network considering distributed photovoltaic access is proposed. Firstly, the characteristic index of distribution network line loss after distributed photovoltaic access is extracted, and the correlation between the line loss index and line loss of the distribution network is calculated by using the gray correlation analysis method, and the correlation degree is ranked. Then, according to the order of gray correlation degree, appropriate indicators are selected for fuzzy C-means clustering, and outliers in each category are detected based on the K-nearest neighbor algorithm to determine whether there is an abnormal line loss in the distribution network. Finally, the verification analysis is carried out through the example, and the results show that the proposed method can effectively identify whether abnormal line loss occurs in the distribution network containing distributed photovoltaics.
- Open Access
- 17 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Identification of Overhead Lines in Low-voltage Distribution Network Based on Graph Convolutional Neural Network
In order to extract power lines in real time and accurately from aerial images of low-voltage distribution overhead lines with complex background and serious occlusion, a low-voltage overhead line recognition algorithm based on graph convolutional neural network was proposed. First, the original image is preprocessed by grayscale and Gaussian filtering. Second, a modified conventional convolutional neural network model is used to locate and identify power lines and auxiliary objects in foreground images. Finally, the post-processing module based on the graph convolutional neural network judges the power lines according to the adjacency relationship of each candidate target, to ensure the precise identification and removal of incorrect power line classifications, our objective is to achieve real-time, high-precision identification of overhead lines within the low-voltage distribution network. The experimental results show that compared with other methods such as YOLOV4, this method has the highest accuracy and extraction speed, and the mAP value can reach 93.6%, which meets the needs of practical work.
- 17 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessIdentification of Overhead Lines in Low-voltage Distribution Network Based on Graph Convolutional Neural Network
In order to extract power lines in real time and accurately from aerial images of low-voltage distribution overhead lines with complex background and serious occlusion, a low-voltage overhead line recognition algorithm based on graph convolutional neural network was proposed. First, the original image is preprocessed by grayscale and Gaussian filtering. Second, a modified conventional convolutional neural network model is used to locate and identify power lines and auxiliary objects in foreground images. Finally, the post-processing module based on the graph convolutional neural network judges the power lines according to the adjacency relationship of each candidate target, to ensure the precise identification and removal of incorrect power line classifications, our objective is to achieve real-time, high-precision identification of overhead lines within the low-voltage distribution network. The experimental results show that compared with other methods such as YOLOV4, this method has the highest accuracy and extraction speed, and the mAP value can reach 93.6%, which meets the needs of practical work.
- 1 January 2022
- Published by Inderscience Publishers in International Journal of Information and Communication Technology
- Vol. 20 (2) , 177
Design of real-time monitoring system for transmission channel energy consumption in wireless sensor networks
The collection of energy consumption data of the transmission channel of the wireless sensor network is neglected, which has the problem that the operation rate of the network is low and the time i...
- 1 January 2022
- Published by Inderscience Publishers in International Journal of Information and Communication Technology
- Vol. 20 (2) , 177
Design of real-time monitoring system for transmission channel energy consumption in wireless sensor networks
The collection of energy consumption data of the transmission channel of the wireless sensor network is neglected, which has the problem that the operation rate of the network is low and the time i...