ISInge P. Salzmann

Inge P. Salzmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Inge P. Salzmann has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accelerometer-derived Step Metrics and Quality of Life in Individuals with and without Cardiovascular Diseases

    by Sabine Schootemeijer, Sophie H. Kroesen, Niels A. Stens, Milou Netten, Inge P. Salzmann, Annemarie Koster, Neeltje A.E. Allard, Bram M.A. van Bakel, Francisco B. Ortega, Emmanuel Stamatakis, et al.

    Background and Aims: Steps are increasingly used to prescribe physical activity, but their impact on quality of life (QoL) remains unclear. We examined the dose-response association between step metrics and QoL, and whether cardiovascular disease (CVD) status moderates this association. Methods: Individual-level data of five studies were pooled. Physical activity was measured with thigh-worn accelerometry. We assessed steps/day, daily minutes of fast stepping (≥100 steps/min), peak 1- and 30- min cadence. We investigated the association of step metrics and QoL (questionnaire-based; standardized) with multivariable (non-)linear regression, and the interaction with CVD status. Results: We included 9,371 participants (62 [54-68] years; 47% female), comprising 1,977 individuals with and 7,394 without CVD. Significant, curvilinear dose-response associations between step metrics and QoL were found. The optimal step volume was 6,561 steps/day which associated with a 0.35 SD (95%CI: 0.28-0.42) higher QoL compared to the referent 4,000 steps/day. The optimal doses for peak 1-min and peak 30-min cadence were 107 steps/minute (+0.34 SD; 95%CI: 0.28-0.41) and 74 steps/minute (+0.29 SD; 95%CI: 0.24-0.34) respectively, compared to references of 90 and 60 steps/minute. Only fast stepping interacted with CVD status, with a lower optimum in those with versus without CVD (4 minutes/day, +0.20 SD, 95%CI: 0.12-0.28 versus 9 minutes/day, +0.19 SD, 95%CI: 0.12-0.25), compared to the referent 2 minutes/day. Conclusions: Step metrics were curvilinearly associated with QoL with optimal benefits at ∼6,500 steps/day. Optimal QoL benefits can be reached at feasible stepping targets, and at slightly fewer daily minutes of fast stepping in CVD versus non-CVD. Structured graphical Key Questions: Is there a dose-response association between step metrics and health-related quality of life (QoL)? Does the cardiovascular disease (CVD) health status moderate this association? Key Findings: More steps/day and time spent at fast stepping are associated with better QoL following a curvilinear dose-response curve. The optimal step volume is 6,561 steps/day, which was independent of CVD status. Individuals with CVD may gain optimal QoL levels at slightly less time of fast stepping (4 min/day) than those without CVD (9 min/day). Take Home Message: More steps and steps at a higher intensity are associated with better QoL. Optimal QoL benefits could be gained at feasible stepping targets (i.e. 4 min/day of fast stepping for CVD, 9 min/day for those without CVD).

  • Validation of Contact Measurement System for Wheelchair Tennis Propulsion Using Marker-Less Vision System

    by Enrico Ferlinghetti, Inge Salzmann, Marco Ghidelli, Thomas Rietveld, Riemer Vegter, Matteo Lancini

    This study investigates the reliability of marker-less vision systems for contact detection between hand and hand-rim during wheelchair propulsion. The measurement system uses a camera collecting RGB and depth images. The hand is detected through Mediapipe, a software able to recognize the key points of the hand on the RGB image. Hand position is expressed with respect to the wheel. A classifier is used to determine if there is contact between hand and hand-rim. To validate this procedure, 17 able-bodied participants pushed the wheelchair on an ergometer during six tests, given by the combinations of holding a tennis racket in their right hand while propelling at three different speeds: 4 km/h, 5.4 km/h and maximal sprint. Since validated contact detection methods are lacking in literature, experts provided a reference by manually evaluating video recordings and force signals frame-by-frame. The results showed that the hand identification by Mediapipe is not influenced by the presence of the racket but by the speed. Contact events were detected in the 99.5% of the cases. The mean error in contact time detection was -5 ms for the starts and 18 ms for the ends, the standard deviation was 48 ms for both and the combined root mean square error (RMSE) was 48 ms for the starts and 50 ms for the ends. These values, once corrected the systematic effects, lead to a standard uncertainty of approximately 0.05 s, corresponding to 15 % of the average contact duration. The study highlights the potential use of marker-less vision systems for contact detection in wheelchair propulsion.