Sanjeev R Kane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sanjeev R Kane has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Pooja Gupta
Raja Ramanna Centre for Advanced Technology Indore India
2 shared publications S. Satapathy
Homi Bhabha National Institute, BARC Training School Complex, Anushaktinagar, India
2 shared publications- Sanjay Kumar Rai
Indus Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology 1 , Indore 452013
2 shared publications A. K. Singh
Synchrotrons Utilization Section, Raja Ramanna Centre for Advanced Technology, Indore 452013, India
1 shared publicationA. Sagdeo
1 shared publicationA.K. Biswas
1 shared publication
Latest Publications
- 2 October 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 44 (6)
Optimization of thickness uniformity in large area coatings using ion assisted electron beam evaporation: Numerical and experimental investigation
Achieving highly uniform thin film coatings over the large area is a critical technological challenge in the fabrication of high-performance x-ray mirrors. The coating thickness nonuniformity in an indigenously developed ultrahigh vacuum ion-assisted electron beam evaporation system equipped with a substrate rotation subsystem is systematically investigated through combined numerical simulations and experiments for rotating flat and curve substrates. The effects of substrate height, source offset, and substrate curvature on the thickness distribution profile are analyzed. Ni thin film samples are coated on small Si substrates distributed over 300 × 100 mm2 area for thickness distribution and microstructure analysis. A thickness nonuniformity of ∼3.17% is achieved with corresponding maximum coating induced slope error of ∼25 nrad across the length of a 300 mm flat surface. For the rotating cylindrical curved surface having a radius of curvature of 500 mm, the measured thickness nonuniformity decreases to ∼1.87%, with corresponding maximum slope error arises due to coating nonuniformity of ∼18 nrad across the length of 300 mm. This study provides practical design guidelines for deposition systems aimed at achieving highly uniform large area coatings.
- 2 October 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 44 (6)
Optimization of thickness uniformity in large area coatings using ion assisted electron beam evaporation: Numerical and experimental investigation
Achieving highly uniform thin film coatings over the large area is a critical technological challenge in the fabrication of high-performance x-ray mirrors. The coating thickness nonuniformity in an indigenously developed ultrahigh vacuum ion-assisted electron beam evaporation system equipped with a substrate rotation subsystem is systematically investigated through combined numerical simulations and experiments for rotating flat and curve substrates. The effects of substrate height, source offset, and substrate curvature on the thickness distribution profile are analyzed. Ni thin film samples are coated on small Si substrates distributed over 300 × 100 mm2 area for thickness distribution and microstructure analysis. A thickness nonuniformity of ∼3.17% is achieved with corresponding maximum coating induced slope error of ∼25 nrad across the length of a 300 mm flat surface. For the rotating cylindrical curved surface having a radius of curvature of 500 mm, the measured thickness nonuniformity decreases to ∼1.87%, with corresponding maximum slope error arises due to coating nonuniformity of ∼18 nrad across the length of 300 mm. This study provides practical design guidelines for deposition systems aimed at achieving highly uniform large area coatings.
- 9 June 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (7) , 591
Ferroelectric polymer–ceramic composites for hard X-ray detection and XANES application
- 9 June 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (7) , 591
Ferroelectric polymer–ceramic composites for hard X-ray detection and XANES application
- Open Access
- 1 December 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (12)
Optimizing pyroelectric x-ray detectors for synchrotron applications
This study presents a comprehensive investigation of pyroelectric detectors for high-energy x-ray detection. We compare three high-performance pyroelectric materials (LiTaO3, LiNbO3, and triglycine sulfate) in two geometries, thermally coupled and uncoupled, and contrasting current with conventional voltage amplifier designs. The results obtained using 17 keV synchrotron radiation demonstrate that current amplification significantly outperforms voltage follower configurations, achieving responsivity values of up to 105 V/W with substantially improved signal-to-noise ratios. Of the three materials tested, triglycine sulfate exhibits superior sensitivity when used in thicker formats (specific detectivity D* ∼ 7.60 × 107 cm Hz1/2 W−1), although LiTaO3 offers better thermal stability for practical applications. Further optimization through thickness reduction of LiTaO3 crystals in the range of 500–100 μm yielded substantial improvements in D*, with the thinnest crystals achieving D* values of ∼1.1 × 108 cm Hz1/2 W−1 in uncoupled geometry, which maximizes thermal isolation and temperature rise per unit-absorbed power. These results validate our theoretical models, which predict performance enhancements through optimal thermal management and amplification strategies. This establishes new benchmarks for pyroelectric-based x-ray detection.
- 1 December 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (12)
Open AccessOptimizing pyroelectric x-ray detectors for synchrotron applications
This study presents a comprehensive investigation of pyroelectric detectors for high-energy x-ray detection. We compare three high-performance pyroelectric materials (LiTaO3, LiNbO3, and triglycine sulfate) in two geometries, thermally coupled and uncoupled, and contrasting current with conventional voltage amplifier designs. The results obtained using 17 keV synchrotron radiation demonstrate that current amplification significantly outperforms voltage follower configurations, achieving responsivity values of up to 105 V/W with substantially improved signal-to-noise ratios. Of the three materials tested, triglycine sulfate exhibits superior sensitivity when used in thicker formats (specific detectivity D* ∼ 7.60 × 107 cm Hz1/2 W−1), although LiTaO3 offers better thermal stability for practical applications. Further optimization through thickness reduction of LiTaO3 crystals in the range of 500–100 μm yielded substantial improvements in D*, with the thinnest crystals achieving D* values of ∼1.1 × 108 cm Hz1/2 W−1 in uncoupled geometry, which maximizes thermal isolation and temperature rise per unit-absorbed power. These results validate our theoretical models, which predict performance enhancements through optimal thermal management and amplification strategies. This establishes new benchmarks for pyroelectric-based x-ray detection.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
A versatile beamline for soft x-ray reflectivity, absorption, and fluorescence measurements at Indus-2 synchrotron source
A versatile beamline for performing reflectivity, fluorescence, and absorption experiments in the soft x-ray region of 100–1500 eV is commissioned on a bending magnet port of the Indus-2 synchrotron source. A high vacuum 2-axis reflectometer with x, y, and z sample scanning stages is installed. This reflectometer is used to measure the reflectivity of large samples up to 300 mm in length and 5 kg in weight. This feature is useful for characterizing x-ray optical elements, such as mirrors, gratings, and multilayers. A flange mounted silicon drift detector is installed in the downstream of the reflectometer for soft x-ray fluorescence measurements. The soft x-ray absorption measurements are carried out in the total electron yield and partial fluorescence yield modes. Integration of three different experimental techniques in the experimental station makes the beamline versatile for materials science applications as it provides structural, chemical, and electronic state information by performing the required experiments in an identical environment. The beamline uses a varied line spacing plane grating monochromator and gives a high flux (∼109 to 1011 photon/s) with a moderate resolution (λ/Δλ ~1000–5000). A three-mirror-based higher harmonic setup is incorporated to get rid of harmonics and to get a high spectral purity monochromatic beam with less than 0.1% harmonic content. In the present article, the beamline optical scheme, mechanical configuration, and details of the experimental setups are presented, along with a few representative results of each experimental mode.
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Open AccessA versatile beamline for soft x-ray reflectivity, absorption, and fluorescence measurements at Indus-2 synchrotron source
A versatile beamline for performing reflectivity, fluorescence, and absorption experiments in the soft x-ray region of 100–1500 eV is commissioned on a bending magnet port of the Indus-2 synchrotron source. A high vacuum 2-axis reflectometer with x, y, and z sample scanning stages is installed. This reflectometer is used to measure the reflectivity of large samples up to 300 mm in length and 5 kg in weight. This feature is useful for characterizing x-ray optical elements, such as mirrors, gratings, and multilayers. A flange mounted silicon drift detector is installed in the downstream of the reflectometer for soft x-ray fluorescence measurements. The soft x-ray absorption measurements are carried out in the total electron yield and partial fluorescence yield modes. Integration of three different experimental techniques in the experimental station makes the beamline versatile for materials science applications as it provides structural, chemical, and electronic state information by performing the required experiments in an identical environment. The beamline uses a varied line spacing plane grating monochromator and gives a high flux (∼109 to 1011 photon/s) with a moderate resolution (λ/Δλ ~1000–5000). A three-mirror-based higher harmonic setup is incorporated to get rid of harmonics and to get a high spectral purity monochromatic beam with less than 0.1% harmonic content. In the present article, the beamline optical scheme, mechanical configuration, and details of the experimental setups are presented, along with a few representative results of each experimental mode.
- 28 December 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1060
Extended X-ray absorption fine structure (EXAFS) measurement of Cu metal foil using thermal wave detector: A comparative study
- 28 December 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1060
Extended X-ray absorption fine structure (EXAFS) measurement of Cu metal foil using thermal wave detector: A comparative study
- 27 May 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (4) , 1193-1201
BL-02: a versatile X-ray scattering and diffraction beamline for engineering applications at Indus-2 synchrotron source
A hard X-ray engineering applications beamline (BL-02) was commissioned recently and started operation in March 2019 at the Indian synchrotron source, Indus-2. This bending-magnet-based beamline is capable of operating in various beam modes, viz. white, pink and monochromatic beam. The beamline utilizes the X-ray diffraction technique in energy-dispersive and angle-dispersive modes to carry out experiments mainly focused on engineering problems, viz. stress measurement, texture measurement and determination of elastic constants in a variety of bulk as well as thin-film samples. An open-cradle six-circle diffractometer with ∼12 kg load capacity allows accommodation of a wide variety of engineering samples and qualifies the beamline as a unique facility at Indus-2. The high-resolution mode of this beamline is suitably designed so as to carry out line profile analysis for characterization of micro- and nano-structures. In the present article the beamline is described starting from the beamline design, layout, optics involved, various operational modes and experimental stations. Experiments executed to validate the beamline design parameters and to demonstrate the capabilities of the beamline are also described. The future facilities to be incorporated to enhance the capabilities of the beamline are also discussed.
- 27 May 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (4) , 1193-1201
BL-02: a versatile X-ray scattering and diffraction beamline for engineering applications at Indus-2 synchrotron source
A hard X-ray engineering applications beamline (BL-02) was commissioned recently and started operation in March 2019 at the Indian synchrotron source, Indus-2. This bending-magnet-based beamline is capable of operating in various beam modes, viz. white, pink and monochromatic beam. The beamline utilizes the X-ray diffraction technique in energy-dispersive and angle-dispersive modes to carry out experiments mainly focused on engineering problems, viz. stress measurement, texture measurement and determination of elastic constants in a variety of bulk as well as thin-film samples. An open-cradle six-circle diffractometer with ∼12 kg load capacity allows accommodation of a wide variety of engineering samples and qualifies the beamline as a unique facility at Indus-2. The high-resolution mode of this beamline is suitably designed so as to carry out line profile analysis for characterization of micro- and nano-structures. In the present article the beamline is described starting from the beamline design, layout, optics involved, various operational modes and experimental stations. Experiments executed to validate the beamline design parameters and to demonstrate the capabilities of the beamline are also described. The future facilities to be incorporated to enhance the capabilities of the beamline are also discussed.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 033301
Experimental setup to measure thermal waves generated by X-ray absorption using pyroelectric sensor
Pyroelectric detectors are widely used for infrared radiation detection, whereas these can also be used in the X-ray region. They have multiple advantages when used at synchrotron radiation sources, such as (a) can be used with a white beam (high flux), (b) have a flat spectral response, and (c) can be used both as a detector and as a sample. However, when used in the hard X-ray region, absorption in the detector plays an important role depending upon the thickness of the detector. Hence, the estimation of the responsivity of the detector is important. In this paper, we report an improved experimental setup for the measurement of a pyroelectric signal in the hard X-ray region. The responsivity (V/W) of a pyroelectric detector for absorbed radiation in the hard x-ray region is measured. Measurements of the K-edge x-ray absorption fine structure of 10-μm copper and nickel foils are carried out using a LiTaO3 pyroelectric detector and compared with the measurements carried out using an ionization chamber as a sensor for the same foils. Absorption spectra near the Ta LIII and LII edges in LiTaO3, measured using a LiTaO3 crystal both as a sample and as a sensor, are also reported in this paper.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 033301
Experimental setup to measure thermal waves generated by X-ray absorption using pyroelectric sensor
Pyroelectric detectors are widely used for infrared radiation detection, whereas these can also be used in the X-ray region. They have multiple advantages when used at synchrotron radiation sources, such as (a) can be used with a white beam (high flux), (b) have a flat spectral response, and (c) can be used both as a detector and as a sample. However, when used in the hard X-ray region, absorption in the detector plays an important role depending upon the thickness of the detector. Hence, the estimation of the responsivity of the detector is important. In this paper, we report an improved experimental setup for the measurement of a pyroelectric signal in the hard X-ray region. The responsivity (V/W) of a pyroelectric detector for absorbed radiation in the hard x-ray region is measured. Measurements of the K-edge x-ray absorption fine structure of 10-μm copper and nickel foils are carried out using a LiTaO3 pyroelectric detector and compared with the measurements carried out using an ionization chamber as a sensor for the same foils. Absorption spectra near the Ta LIII and LII edges in LiTaO3, measured using a LiTaO3 crystal both as a sample and as a sensor, are also reported in this paper.
- 16 November 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (2) , 026537
Correlation of B2 super-lattice ordering with soft magnetic and mechanical properties of nanocrystalline FeCoNbB HITPERM alloys
- 16 November 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (2) , 026537
Correlation of B2 super-lattice ordering with soft magnetic and mechanical properties of nanocrystalline FeCoNbB HITPERM alloys
- 19 December 2015
- Published by Springer Nature in Applied Physics A
- Vol. 122 (1) , 1-5
Study of XANES near Ta-L edges in LiTaO3 through thermal wave, fluorescence and first principles
- 19 December 2015
- Published by Springer Nature in Applied Physics A
- Vol. 122 (1) , 1-5
Study of XANES near Ta-L edges in LiTaO3 through thermal wave, fluorescence and first principles