Dagan Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dagan Yang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Lina Fan
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
6 shared publicationsXinglun Qi
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
5 shared publicationsZheng Yang
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
3 shared publications- Xianfei Ye
Department of Laboratory Medicine, the First Affiliated Hospital Zhejiang University School of Medicine Hangzhou People's Republic of China
2 shared publications - Chunyun Ren
Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, 79 Qingchun Road, Hangzhou, Zhejiang, China, 86 0571-87236383
1 shared publication - Cong-Ying Song
Department of Geriatric and Emergency Medicine, School of Medicine, The First Affiliated Hospital, Zhejiang University, Hangzhou, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by Springer Nature in BMC Cancer
Establishment of stratified reference intervals for serum CA125 using five algorithms based on real-world big data and evaluation of clinical performance
- 25 September 2026
- Published by Springer Nature in BMC Cancer
Open AccessEstablishment of stratified reference intervals for serum CA125 using five algorithms based on real-world big data and evaluation of clinical performance
- Open Access
- 5 June 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28 (1) , e87802
Performance Evaluation of GPT-5, Grok 4, and DeepSeek R1 in Interpreting Complete Blood Count Reports for Hematologic Diseases: Retrospective Comparative Study
Background: Large language models (LLMs) demonstrate potential in the laboratory, yet rigorous clinical evaluation remains limited. The opacity of LLM decision-making constrains their safe application in interpreting complete blood count (CBC) reports for hematologic diseases. Objective: This study aimed to conduct an exploratory evaluation of GPT-5, Grok 4, and DeepSeek R1 in interpreting real-world CBC reports, particularly their reasoning capabilities and clinical safety. Methods: This single-center retrospective study analyzed 100 CBC reports from initial-visit patients with hematologic conditions. After responses were generated by the 3 LLMs using standardized Chinese prompts, four trained laboratory physicians blindly evaluated them across 6 quality and 5 task dimensions. Interrater reliability was assessed using intraclass correlation coefficients (ICCs), and performance differences were assessed based on 4-rater consensus scores and Friedman and Wilcoxon tests. For task 4 (ablation analysis), the McNemar test was used to compare top-1 diagnostic concordance with the gold-standard diagnosis within each model, with and without initial clinical suspicion in the prompt. Error types and distributions were documented during the task evaluation. Results: DeepSeek R1 demonstrated excellent interrater reliability across most quality dimensions (ICC ≥0.75). In the quality dimension, DeepSeek R1 significantly outperformed the other models in comprehensiveness, accuracy, clarity, relevance, and practicality. In the task 4 evaluation, GPT-5 demonstrated the highest concordance (93/100, 93%) with gold-standard diagnoses, followed by DeepSeek R1 (92/100, 92%) and Grok 4 (89/100, 89%). After removing the initial clinical suspicion, these rates decreased to 79% (79/100), 77% (77/100), and 72% (72/100), representing statistically significant within-model reductions for all models ( P <.001). Post hoc error analysis revealed distinct patterns across task dimensions. GPT-5 exhibited 12 hallucinations in the analyzer alert processing task; DeepSeek R1 demonstrated 1 hallucination in the abnormal item identification task, whereas Grok 4 displayed none. All models exhibited reasoning errors and varying degrees of deficiencies in the correlation analysis and preliminary diagnosis tasks, characterized by unwarranted inferences of disease status from isolated results without clinical integration. Grok 4 generated 9 reasoning errors in the clinical management task by providing generic recommendations not tailored to case-specific CBC data, potentially compromising individualized treatment decisions. Conclusions: While current LLMs demonstrate potential for interpreting CBC reports in hematologic diseases, they show performance heterogeneity across models. The ablation study findings underscore the necessity of integrating clinical context for accurate laboratory test interpretation. Low scores, hallucinations, and reasoning errors in model outputs indicate that current clinical deployment requires human oversight and quality control. As this single-center, Chinese-language exploratory assessment provides only preliminary, possibly context-dependent evidence, multicenter, cross-lingual prospective validation is needed to delineate the practical boundaries and safety standards for clinical deployment.
- 5 June 2026
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 28 (1) , e87802
Open AccessPerformance Evaluation of GPT-5, Grok 4, and DeepSeek R1 in Interpreting Complete Blood Count Reports for Hematologic Diseases: Retrospective Comparative Study
Background: Large language models (LLMs) demonstrate potential in the laboratory, yet rigorous clinical evaluation remains limited. The opacity of LLM decision-making constrains their safe application in interpreting complete blood count (CBC) reports for hematologic diseases. Objective: This study aimed to conduct an exploratory evaluation of GPT-5, Grok 4, and DeepSeek R1 in interpreting real-world CBC reports, particularly their reasoning capabilities and clinical safety. Methods: This single-center retrospective study analyzed 100 CBC reports from initial-visit patients with hematologic conditions. After responses were generated by the 3 LLMs using standardized Chinese prompts, four trained laboratory physicians blindly evaluated them across 6 quality and 5 task dimensions. Interrater reliability was assessed using intraclass correlation coefficients (ICCs), and performance differences were assessed based on 4-rater consensus scores and Friedman and Wilcoxon tests. For task 4 (ablation analysis), the McNemar test was used to compare top-1 diagnostic concordance with the gold-standard diagnosis within each model, with and without initial clinical suspicion in the prompt. Error types and distributions were documented during the task evaluation. Results: DeepSeek R1 demonstrated excellent interrater reliability across most quality dimensions (ICC ≥0.75). In the quality dimension, DeepSeek R1 significantly outperformed the other models in comprehensiveness, accuracy, clarity, relevance, and practicality. In the task 4 evaluation, GPT-5 demonstrated the highest concordance (93/100, 93%) with gold-standard diagnoses, followed by DeepSeek R1 (92/100, 92%) and Grok 4 (89/100, 89%). After removing the initial clinical suspicion, these rates decreased to 79% (79/100), 77% (77/100), and 72% (72/100), representing statistically significant within-model reductions for all models ( P <.001). Post hoc error analysis revealed distinct patterns across task dimensions. GPT-5 exhibited 12 hallucinations in the analyzer alert processing task; DeepSeek R1 demonstrated 1 hallucination in the abnormal item identification task, whereas Grok 4 displayed none. All models exhibited reasoning errors and varying degrees of deficiencies in the correlation analysis and preliminary diagnosis tasks, characterized by unwarranted inferences of disease status from isolated results without clinical integration. Grok 4 generated 9 reasoning errors in the clinical management task by providing generic recommendations not tailored to case-specific CBC data, potentially compromising individualized treatment decisions. Conclusions: While current LLMs demonstrate potential for interpreting CBC reports in hematologic diseases, they show performance heterogeneity across models. The ablation study findings underscore the necessity of integrating clinical context for accurate laboratory test interpretation. Low scores, hallucinations, and reasoning errors in model outputs indicate that current clinical deployment requires human oversight and quality control. As this single-center, Chinese-language exploratory assessment provides only preliminary, possibly context-dependent evidence, multicenter, cross-lingual prospective validation is needed to delineate the practical boundaries and safety standards for clinical deployment.
- Open Access
- 19 April 2026
- Published by Elsevier in SSRN Electronic Journal
Development and External Validation of a Model for Identifying Infection in Multiple Autoimmune Disease Based on Machine Learning
Background: Infection in patients with autoimmune diseases (AID) significantly worsens clinical outcomes. Conventional biomarkers often fail to accurately detect infections, and existing prediction models are limited by their disease-specific nature or reliance on non-routine data. To address this, we developed a robust machine learning (ML) model based on routine clinical data to identify infections across multiple AID.Methods: A development cohort of 4,364 AID patients and an external validation cohort of 4,241 patients from another tertiary hospital were retrospectively collected in our study. Four machine learning (ML) models were compared via 5-fold nested cross-validation (CV). In the inner loop, feature selection and the optimal number of features were determined based on average importance and Top-k curves. The final model was determined by evaluating performance on the outer test sets within the outer loop and interpreted using SHapley Additive exPlanations (SHAP). Model performance was rigorously evaluated using sensitivity, specificity, F1-score, receiver operating characteristic (ROC) curves, and precision-recall (PR) curves, while decision curve analysis (DCA) and calibration curves were employed to assess clinical utility. DeLong test was used to determine the statistically significant differences of ROC between different models.Findings: XGBoost emerged as the optimal model, utilizing 20 key indicators including procalcitonin, C-reactive protein, Fever status, lactate dehydrogenase, White blood cells per high-power field, albumin, D-Dimer, Age, Immunoglobulin G, Serum Potassium, Lymphocyte Ratio, Creatine Kinase, Fibrinogen, Platelet-to-lymphocyte ratio, Lymphocyte, Estimated Glomerular Filtration Rate, Erythrocyte Sedimentation Rate to C-reactive Protein ratio, neutrophil-to-lymphocyte ratio, Serum Sodium and immunoglobulin A. XGBoost model achieved a sensitivity of 0.891, specificity of 0.791, F1-score of 0.577, AUROC of 0.931, AUPR of 0.798 and a Brier score of 0.065. External validation demonstrated superior performance with a sensitivity of 0.871, specificity of 0.762, F1-score of 0.558, AUROC of 0.899, AUPR of 0.772 and a Brier score of 0.069.Interpretation: The XGBoost model, encompassing multiple AID subtypes and incorporating 20 key indicators, demonstrates superior performance and broad clinical applicability. By requiring routine laboratory tests, it enables efficient assessment of infection status in AID patients, providing a reliable tool for infection monitoring of AID patients.
- 19 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment and External Validation of a Model for Identifying Infection in Multiple Autoimmune Disease Based on Machine Learning
Background: Infection in patients with autoimmune diseases (AID) significantly worsens clinical outcomes. Conventional biomarkers often fail to accurately detect infections, and existing prediction models are limited by their disease-specific nature or reliance on non-routine data. To address this, we developed a robust machine learning (ML) model based on routine clinical data to identify infections across multiple AID.Methods: A development cohort of 4,364 AID patients and an external validation cohort of 4,241 patients from another tertiary hospital were retrospectively collected in our study. Four machine learning (ML) models were compared via 5-fold nested cross-validation (CV). In the inner loop, feature selection and the optimal number of features were determined based on average importance and Top-k curves. The final model was determined by evaluating performance on the outer test sets within the outer loop and interpreted using SHapley Additive exPlanations (SHAP). Model performance was rigorously evaluated using sensitivity, specificity, F1-score, receiver operating characteristic (ROC) curves, and precision-recall (PR) curves, while decision curve analysis (DCA) and calibration curves were employed to assess clinical utility. DeLong test was used to determine the statistically significant differences of ROC between different models.Findings: XGBoost emerged as the optimal model, utilizing 20 key indicators including procalcitonin, C-reactive protein, Fever status, lactate dehydrogenase, White blood cells per high-power field, albumin, D-Dimer, Age, Immunoglobulin G, Serum Potassium, Lymphocyte Ratio, Creatine Kinase, Fibrinogen, Platelet-to-lymphocyte ratio, Lymphocyte, Estimated Glomerular Filtration Rate, Erythrocyte Sedimentation Rate to C-reactive Protein ratio, neutrophil-to-lymphocyte ratio, Serum Sodium and immunoglobulin A. XGBoost model achieved a sensitivity of 0.891, specificity of 0.791, F1-score of 0.577, AUROC of 0.931, AUPR of 0.798 and a Brier score of 0.065. External validation demonstrated superior performance with a sensitivity of 0.871, specificity of 0.762, F1-score of 0.558, AUROC of 0.899, AUPR of 0.772 and a Brier score of 0.069.Interpretation: The XGBoost model, encompassing multiple AID subtypes and incorporating 20 key indicators, demonstrates superior performance and broad clinical applicability. By requiring routine laboratory tests, it enables efficient assessment of infection status in AID patients, providing a reliable tool for infection monitoring of AID patients.
- 13 April 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (8) , 1826-1837
Performance evaluation of five large language models for assisting in the interpretation of urinalysis reports for kidney diseases: a real-world study
Objectives: Large language models (LLMs) show promise for interpreting laboratory reports, yet real-world validation remains limited. This study evaluated five advanced LLMs in interpreting urinalysis reports for kidney diseases using real-world clinical data, providing empirical evidence for the utility of LLM-assisted result interpretation. Methods: We retrospectively collected 120 urinalysis reports from patients with primary glomerular diseases and secondary nephropathies. The testing platforms included the Sysmex UF5000 and Mindray EU8600. Five LLMs (ChatGPT-5, Claude-4.5, Gemini-2.5, DeepSeek-V3.1, Qwen-3) were tasked with interpreting reports across five functional dimensions. Four certified laboratory technologists and four licensed physicians evaluated outputs using a 5-point Likert scale across six quality dimensions. Statistical analyses employed Friedman and Wilcoxon signed-rank tests. Results: All five LLMs demonstrated clinical utility in interpreting urinalysis reports. Proprietary LLMs achieved higher overall scores (Claude-4.5: 4.78 ± 0.47; ChatGPT-5: 4.73 ± 0.50; Gemini-2.5: 4.69 ± 0.54) compared to open-source LLMs (DeepSeek-V3.1: 4.58 ± 0.66; Qwen-3: 4.57 ± 0.69). Across functional dimensions, the models performed proficiently in identifying abnormal parameters and analyzing their correlations, but suboptimally in interpreting instrument flags. Instrument-dependent variability was observed (Sysmex vs. Mindray, p<0.001). In quality assessments, Claude-4.5 exhibited the best overall performance, ChatGPT-5 excelled in accuracy and clarity, and Gemini-2.5 demonstrated strong practicality. Regarding safety, Claude-4.5 exhibited the lowest hallucination rate (7.5 %). Common hallucinations included misinterpretation, definition errors, and over-interpretation. Conclusions: LLMs demonstrate significant capability in urinalysis interpretation, though proprietary models currently excel in reasoning and hallucination resistance. Instrument-specific flag interpretation and hallucination mitigation remain critical challenges requiring Retrieval-Augmented Generation (RAG) integration and human oversight.
- 13 April 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (8) , 1826-1837
Performance evaluation of five large language models for assisting in the interpretation of urinalysis reports for kidney diseases: a real-world study
Objectives: Large language models (LLMs) show promise for interpreting laboratory reports, yet real-world validation remains limited. This study evaluated five advanced LLMs in interpreting urinalysis reports for kidney diseases using real-world clinical data, providing empirical evidence for the utility of LLM-assisted result interpretation. Methods: We retrospectively collected 120 urinalysis reports from patients with primary glomerular diseases and secondary nephropathies. The testing platforms included the Sysmex UF5000 and Mindray EU8600. Five LLMs (ChatGPT-5, Claude-4.5, Gemini-2.5, DeepSeek-V3.1, Qwen-3) were tasked with interpreting reports across five functional dimensions. Four certified laboratory technologists and four licensed physicians evaluated outputs using a 5-point Likert scale across six quality dimensions. Statistical analyses employed Friedman and Wilcoxon signed-rank tests. Results: All five LLMs demonstrated clinical utility in interpreting urinalysis reports. Proprietary LLMs achieved higher overall scores (Claude-4.5: 4.78 ± 0.47; ChatGPT-5: 4.73 ± 0.50; Gemini-2.5: 4.69 ± 0.54) compared to open-source LLMs (DeepSeek-V3.1: 4.58 ± 0.66; Qwen-3: 4.57 ± 0.69). Across functional dimensions, the models performed proficiently in identifying abnormal parameters and analyzing their correlations, but suboptimally in interpreting instrument flags. Instrument-dependent variability was observed (Sysmex vs. Mindray, p<0.001). In quality assessments, Claude-4.5 exhibited the best overall performance, ChatGPT-5 excelled in accuracy and clarity, and Gemini-2.5 demonstrated strong practicality. Regarding safety, Claude-4.5 exhibited the lowest hallucination rate (7.5 %). Common hallucinations included misinterpretation, definition errors, and over-interpretation. Conclusions: LLMs demonstrate significant capability in urinalysis interpretation, though proprietary models currently excel in reasoning and hallucination resistance. Instrument-specific flag interpretation and hallucination mitigation remain critical challenges requiring Retrieval-Augmented Generation (RAG) integration and human oversight.
- 27 March 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 588, 120984
Performance evaluation and comparison of ChatGPT, Gemini, Grok, and DeepSeek in the interpretation of tumor marker reports
- 27 March 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 588, 120984
Performance evaluation and comparison of ChatGPT, Gemini, Grok, and DeepSeek in the interpretation of tumor marker reports
- Open Access
- 26 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Big data-driven establishment and bias comparison of serum ferritin reference intervals in Zhejiang Chinese adults using six algorithms
This study systematically compared the performance of six algorithms for establishing serum ferritin (SF) reference intervals (RIs) using data from large-scale health check-up populations (22,359 cases from Hospital A and 555 cases from Hospital B) and 327 anemia patients. Methods included non-parametric (EP28-NP) and parametric (EP28-P) approaches per EP28-A3c guidelines, along with modern algorithms (TMC, refineR, Kosmic, Bhattacharya). Continuous RIs were constructed using GAMLSS. Results showed good consistency in lower RIs limits between EP28-NP and four modern algorithms. Using EP28-NP as an example, male RIs (20–92 years) were 68.8-495.5 ng/mL, while females exhibited age-gradient characteristics: 20–45 years (10.4-132.5 ng/mL), 46–58 years (13.8-241.6 ng/mL), and 59–90 years (43.7-348.8 ng/mL). All algorithms demonstrated satisfactory validation rates (90.91%-98.67%). Notably, application of laboratory-established RIs significantly increased SF abnormality detection rates in anemia patients from 13.2% to 33.6% compared to manufacturer standards. Continuous RIs revealed significant SF concentration increases in males aged 20–29 years and females aged 46–58 years. The study demonstrates that laboratory-developed RIs better reflect population characteristics than manufacturer standards, and recommends that laboratories select appropriate algorithms based on data distribution to establish localized reference criteria.
- 26 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessBig data-driven establishment and bias comparison of serum ferritin reference intervals in Zhejiang Chinese adults using six algorithms
This study systematically compared the performance of six algorithms for establishing serum ferritin (SF) reference intervals (RIs) using data from large-scale health check-up populations (22,359 cases from Hospital A and 555 cases from Hospital B) and 327 anemia patients. Methods included non-parametric (EP28-NP) and parametric (EP28-P) approaches per EP28-A3c guidelines, along with modern algorithms (TMC, refineR, Kosmic, Bhattacharya). Continuous RIs were constructed using GAMLSS. Results showed good consistency in lower RIs limits between EP28-NP and four modern algorithms. Using EP28-NP as an example, male RIs (20–92 years) were 68.8-495.5 ng/mL, while females exhibited age-gradient characteristics: 20–45 years (10.4-132.5 ng/mL), 46–58 years (13.8-241.6 ng/mL), and 59–90 years (43.7-348.8 ng/mL). All algorithms demonstrated satisfactory validation rates (90.91%-98.67%). Notably, application of laboratory-established RIs significantly increased SF abnormality detection rates in anemia patients from 13.2% to 33.6% compared to manufacturer standards. Continuous RIs revealed significant SF concentration increases in males aged 20–29 years and females aged 46–58 years. The study demonstrates that laboratory-developed RIs better reflect population characteristics than manufacturer standards, and recommends that laboratories select appropriate algorithms based on data distribution to establish localized reference criteria.
- 21 January 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (6) , 1199-1207
Establishment of gender– and age–related reference intervals for serum uric acid in adults based on big data from Zhejiang Province in China
Objectives: This study utilized large-scale health examination data to explore gender– and age–specific reference intervals (RIs) for serum uric acid (UA) using indirect methods and assessed the consistency of different approaches. Methods: UA data were collected from a hospital in Zhejiang Province, China. The test set covered January 2019 to December 2023, with a validation set from January to June 2024. Various methods – EP28 nonparametric (EP28-NP), parametric (EP28-P), TMC, refineR, and Kosmic – were used to establish gender– and age–specific RIs. Continuous age-based RIs were derived using the Generalized Additive Model for Location Scale and Shape (GAMLSS). Validation rates were calculated for each method using the validation set. Results: Using EP28-NP as the benchmark, other methods showed similar UA RIs (bias ratios ≤0.375, except for one group), with Kosmic, refineR, and TMC yielding slightly higher values than EP28-NP and EP28-P. For males, UA RIs varied by age: 19–42 years (256–537 μmol/L), 43–66 years (235–513 μmol/L) and ≥67 years (214–515 μmol/L), with validation rates ranging from 94.05 to 96.50 %. Male continuous RIs declined from ages 20–79 and then gradually increased after age 80. For females, UA RIs were age-dependent: 19–48 years (169–374 μmol/L), 49–74 years (178–405 μmol/L), and ≥75 years (186–470 μmol/L), with validation rates ranging from 92.70 to 96.80 %. Female continuous RIs decreased from ages 20–48, then increased significantly from age 49 onward. Conclusions: Three indirect methods and two EP28 methods demonstrated good consistency in establishing UA RIs. Males had higher RIs than females, and RIs showed a non-linear correlation with age.
- 21 January 2025
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (6) , 1199-1207
Establishment of gender– and age–related reference intervals for serum uric acid in adults based on big data from Zhejiang Province in China
Objectives: This study utilized large-scale health examination data to explore gender– and age–specific reference intervals (RIs) for serum uric acid (UA) using indirect methods and assessed the consistency of different approaches. Methods: UA data were collected from a hospital in Zhejiang Province, China. The test set covered January 2019 to December 2023, with a validation set from January to June 2024. Various methods – EP28 nonparametric (EP28-NP), parametric (EP28-P), TMC, refineR, and Kosmic – were used to establish gender– and age–specific RIs. Continuous age-based RIs were derived using the Generalized Additive Model for Location Scale and Shape (GAMLSS). Validation rates were calculated for each method using the validation set. Results: Using EP28-NP as the benchmark, other methods showed similar UA RIs (bias ratios ≤0.375, except for one group), with Kosmic, refineR, and TMC yielding slightly higher values than EP28-NP and EP28-P. For males, UA RIs varied by age: 19–42 years (256–537 μmol/L), 43–66 years (235–513 μmol/L) and ≥67 years (214–515 μmol/L), with validation rates ranging from 94.05 to 96.50 %. Male continuous RIs declined from ages 20–79 and then gradually increased after age 80. For females, UA RIs were age-dependent: 19–48 years (169–374 μmol/L), 49–74 years (178–405 μmol/L), and ≥75 years (186–470 μmol/L), with validation rates ranging from 92.70 to 96.80 %. Female continuous RIs decreased from ages 20–48, then increased significantly from age 49 onward. Conclusions: Three indirect methods and two EP28 methods demonstrated good consistency in establishing UA RIs. Males had higher RIs than females, and RIs showed a non-linear correlation with age.
- 11 January 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (3) , 457-465
Performance comparison of two automated digital morphology analyzers for leukocyte differential in patients with malignant hematological diseases: Mindray MC‐80 and Sysmex DI‐60
Background: The MC‐80 (Mindray, Shenzhen, China), a newly available artificial intelligence (AI)‐based digital morphology analyzer, is the focus of this study. We aim to compare the leukocyte differential performance of the Mindray MC‐80 with that of the Sysmex DI‐60 and the gold standard, manual microscopy.Methods: A total of 100 abnormal peripheral blood (PB) smears were compared across the MC‐80, DI‐60, and manual microscopy. Sensitivity, specificity, predictive value, and efficiency were calculated according to the Clinical and Laboratory Standards Institute (CLSI) EP12‐A2 guidelines. Comparisons were made using Bland–Altman analysis and Passing‐Bablok regression analysis. Additionally, within‐run imprecision was evaluated using five samples, each with varying percentages of mature leukocytes and blasts, in accordance with CLSI EP05‐A3 guidelines.Results: The within‐run coefficient of variation (%CV) of the MC‐80 for most cell classes in the five samples was lower than that of the DI‐60. Sensitivities for the MC‐80 ranged from 98.2% for nucleated red blood cells (NRBC) to 28.6% for reactive lymphocytes. The DI‐60's sensitivities varied between 100% for basophils and reactive lymphocytes, and 11.1% for metamyelocytes. Both analyzers demonstrated high specificity, negative predictive value, and efficiency, with over 90% for most cell classes. However, the DI‐60 showed relatively lower specificity for lymphocytes (73.2%) and lower efficiency for blasts and lymphocytes (80.1% and 78.6%, respectively) compared with the MC‐80. Bland–Altman analysis indicated that the absolute mean differences (%) ranged from 0.01 to 4.57 in MC‐80 versus manual differential and 0.01 to 3.39 in DI‐60 versus manual differential. After verification by technicians, both analyzers exhibited a very high correlation (r = 0.90–1.00) with the manual differential results in neutrophils, lymphocytes, and blasts.Conclusions: The Mindray MC‐80 demonstrated good performance for leukocyte differential in PB smears, notably exhibiting higher sensitivity for blasts identification than the DI‐60.
- 11 January 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (3) , 457-465
Performance comparison of two automated digital morphology analyzers for leukocyte differential in patients with malignant hematological diseases: Mindray MC‐80 and Sysmex DI‐60
Background: The MC‐80 (Mindray, Shenzhen, China), a newly available artificial intelligence (AI)‐based digital morphology analyzer, is the focus of this study. We aim to compare the leukocyte differential performance of the Mindray MC‐80 with that of the Sysmex DI‐60 and the gold standard, manual microscopy.Methods: A total of 100 abnormal peripheral blood (PB) smears were compared across the MC‐80, DI‐60, and manual microscopy. Sensitivity, specificity, predictive value, and efficiency were calculated according to the Clinical and Laboratory Standards Institute (CLSI) EP12‐A2 guidelines. Comparisons were made using Bland–Altman analysis and Passing‐Bablok regression analysis. Additionally, within‐run imprecision was evaluated using five samples, each with varying percentages of mature leukocytes and blasts, in accordance with CLSI EP05‐A3 guidelines.Results: The within‐run coefficient of variation (%CV) of the MC‐80 for most cell classes in the five samples was lower than that of the DI‐60. Sensitivities for the MC‐80 ranged from 98.2% for nucleated red blood cells (NRBC) to 28.6% for reactive lymphocytes. The DI‐60's sensitivities varied between 100% for basophils and reactive lymphocytes, and 11.1% for metamyelocytes. Both analyzers demonstrated high specificity, negative predictive value, and efficiency, with over 90% for most cell classes. However, the DI‐60 showed relatively lower specificity for lymphocytes (73.2%) and lower efficiency for blasts and lymphocytes (80.1% and 78.6%, respectively) compared with the MC‐80. Bland–Altman analysis indicated that the absolute mean differences (%) ranged from 0.01 to 4.57 in MC‐80 versus manual differential and 0.01 to 3.39 in DI‐60 versus manual differential. After verification by technicians, both analyzers exhibited a very high correlation (r = 0.90–1.00) with the manual differential results in neutrophils, lymphocytes, and blasts.Conclusions: The Mindray MC‐80 demonstrated good performance for leukocyte differential in PB smears, notably exhibiting higher sensitivity for blasts identification than the DI‐60.
- Open Access
- 27 December 2023
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 38, e00353
Comparison of results and age-related changes in establishing reference intervals for CEA, AFP, CA125, and CA199 using four indirect methods
- 27 December 2023
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 38, e00353
Open AccessComparison of results and age-related changes in establishing reference intervals for CEA, AFP, CA125, and CA199 using four indirect methods
- 2 July 2020
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 15 (5) , 871-874
A COVID-19 patient with seven consecutive false-negative rRT-PCR results from sputum specimens
- 2 July 2020
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 15 (5) , 871-874
A COVID-19 patient with seven consecutive false-negative rRT-PCR results from sputum specimens