SCShih-Hao Cheng

Shih-Hao Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shih-Hao Cheng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intraoperative Suction-Assisted Kyphoplasty for Immediate Removal of Posterior PMMA Extravasation in Decompressed Vertebral Compression Fractures

    by Yu-Chuan Tsuei, Hsin-Tzu Lu, Yung-Fu Hsu, Shih-Hao Cheng, William Chu, Woei-Chyn Chu

    Background: Vertebral compression fractures are prevalent in elderly patients with osteoporosis. While the vertebral augmentation procedure is often used for symptom control and improving life quality, cement leakage is still a significant complication of vertebral augmentation procedures. This case report describes a 92-year-old man with a T8 compression fracture who underwent kyphoplasty with low-viscosity bone cement after failed conservative treatment. Methods: A previously developed decompressed kyphoplasty technique using dual portals was employed to reduce intravertebral pressure; however, fluoroscopy revealed posterior leakage toward the spinal canal. A case-specific intraoperative modification of this established technique was then applied, converting the injection portal into a suction channel to aspirate extravasated cement before it hardened. Results: This approach averted spinal cord compromise, obviated the need for additional decompression surgery, and preserved neurological function. The patient achieved rapid pain relief and early mobilization. Conclusions: This case demonstrates how a suction-assisted intraoperative maneuver may be used to manage posterior cement leakage during decompressed kyphoplasty.

  • Open Access

    The Evolution of Spinal Endoscopy: Design and Image Analysis of a Single-Use Digital Endoscope Versus Traditional Optic Endoscope

    by Shih-Hao Cheng, Yen-Tsung Lin, Hsin-Tzu Lu, Yu-Chuan Tsuei, William Chu, Woei-Chyn Chu

    Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy—a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.


  • Open Access

    Assessment of Cement Leakage in Decompressed Percutaneous Kyphoplasty

    by Shih-Hao Cheng, Wen-Hsiang Chou, Yu-Chuan Tsuei, William Chu, Woei-Chyn Chu

    Symptomatic osteoporotic compression fractures are commonly addressed through vertebroplasty and kyphoplasty. However, cement leakage poses a significant risk of neurological damage. We introduced “aspiration percutaneous kyphoplasty”, also known as “decompressed kyphoplasty”, as a method to mitigate cement leakage and conducted a comparative analysis with high viscosity cement vertebroplasty. We conducted a retrospective study that included 136 patients with single-level osteoporotic compression fractures. Among them, 70 patients underwent high viscosity cement vertebroplasty, while 66 patients received decompressed percutaneous kyphoplasty with low-viscosity cement. Comparison parameters included cement leakage rates, kyphotic angle alterations, and the occurrence of adjacent segment fractures. The overall cement leakage rate favored the decompressed kyphoplasty group (9.1% vs. 18.6%), although statistical significance was not achieved (p = 0.111). Nonetheless, the risk of intradiscal leakage significantly reduced in the decompressed kyphoplasty cohort (p = 0.011), which was particularly evident in cases lacking the preoperative cleft sign on X-rays. Kyphotic angle changes and the risk of adjacent segment collapse exhibited similar outcomes (p = 0.739 and 0.522, respectively). We concluded that decompressed kyphoplasty demonstrates efficacy in reducing intradiscal cement leakage, particularly benefiting patients without the preoperative cleft sign on X-rays by preventing intradiscal leakage.