H Chandana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
H Chandana has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Archana Trikkaikuth Chalackal
Fiber Optic Sensing Laboratory, Department of Electronics and Communication Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Chennai, India
1 shared publicationPravin Kumar Subbaraj
Department of Biomedical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Chennai, India
1 shared publication- Srijith Kanakambaran
Electronics and Communication Engineering Department, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram, Chennai, India
1 shared publication
Latest Publications
- 16 January 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (2) , 025007
In-vivo studies on PDMS-embedded fiber Bragg grating based smart laparoscopic grasper
Minimally invasive surgeries are often associated with the risk of tissue damage due to improper force feedback mechanisms to notify surgeons regarding the force thresholds. This work evaluates the grasping forces during tissue handling to offer force feedback and assist surgeons during tissue manipulation. A polydimethylsiloxane embedded fiber Bragg grating sensor was developed and integrated at the tip of the laparoscopic grasper to measure the grasping force. Simulation studies have been performed to investigate the performance of the embedded grating sensor. The sensitivity of the sensor embedded within polydimethylsiloxane was found to be around 31.4 pm N−1 which was better compared to that of a silicone embedded counterpart. In-vivo studies were performed with soft tissue phantoms prepared with silicone rubber interspersed with different concentrations of mineral oil. Experimental results reveal a decrease in the peak wavelength shift as the tissue gets softer which is consistent with the nature of grasping force for softer tissues.
- 16 January 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (2) , 025007
In-vivo studies on PDMS-embedded fiber Bragg grating based smart laparoscopic grasper
Minimally invasive surgeries are often associated with the risk of tissue damage due to improper force feedback mechanisms to notify surgeons regarding the force thresholds. This work evaluates the grasping forces during tissue handling to offer force feedback and assist surgeons during tissue manipulation. A polydimethylsiloxane embedded fiber Bragg grating sensor was developed and integrated at the tip of the laparoscopic grasper to measure the grasping force. Simulation studies have been performed to investigate the performance of the embedded grating sensor. The sensitivity of the sensor embedded within polydimethylsiloxane was found to be around 31.4 pm N−1 which was better compared to that of a silicone embedded counterpart. In-vivo studies were performed with soft tissue phantoms prepared with silicone rubber interspersed with different concentrations of mineral oil. Experimental results reveal a decrease in the peak wavelength shift as the tissue gets softer which is consistent with the nature of grasping force for softer tissues.