Aarathi Pradeep
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aarathi Pradeep has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Punathil Vasu Suneesh
Department of Chemistry Amrita School of Physical Sciences Coimbatore Amrita Vishwa Vidyapeetham Coimbatore Tamil Nadu India
3 shared publications T. G. Satheesh Babu
Department of Chemistry, Amrita School of Physical Sciences Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India
2 shared publications- A. Lakshmi Devi
Department of Sciences, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641 112, India; Amrita Biosensor Research Lab, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Coimbatore 641 112, India
1 shared publication Arun Kumar P
1 shared publicationBipin G. Nair
Amrita School of Biotechnology, Amrita Vishwa Vidyapeetham, Kollam, Kerala, India
1 shared publication- Bipin Nair
School of Biotechnology, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam 690525, Kerala, India
1 shared publication
Latest Publications
- 19 December 2025
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (3) , 1653-1666
A flexible micropatterned capacitive pressure sensor for wearable applications
- 19 December 2025
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (3) , 1653-1666
A flexible micropatterned capacitive pressure sensor for wearable applications
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20805-20812
A User-Configurable Smartwatch as a Point-of-Care Testing Device for Electrochemical Biosensors
The paper presents the development of a wristwatch as a configurable testing platform for personalized point-of-care testing. The developed watch can perform voltammetry and amperometry in a wide operating range, thus making the system capable of detecting various bio-analytes. This overcomes a major limitation of the existing meters available in the market, where each sensor requires a dedicated meter. The user selects the desired biomolecule for quantification on the smartphone using the developed Android mobile application. The test parameters are transferred via Bluetooth, and the smartwatch is tuned to the chosen sensor. As a proof-of-concept, we have developed electrochemical biosensors for testing clinically significant biomolecules like glucose, uric acid and ascorbic acid, which was then interfaced with the smartwatch for the on-demand quantification. Using an ADC with 12-bit resolution, the device demonstrated a high resolution of 0.732 mV. The smartwatch could overcome the limitation associated with the quantification of uric acid in the presence of ascorbic acid by doing baseline subtraction, and the results show a low relative standard deviation of 4%. The glucose analysis was highly reproducible with a relative standard deviation of 4.95%, with a high resolution of 0.0217 mg dL -1 , and the results could be obtained within 5 s. The results obtained using the smartwatch were in excellent conformity with those obtained from a laboratory electrochemical workstation. The key advantage of the device is that it can be easily configured to test any new biomarkers without any hardware change by over-the-air mobile application updates.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20805-20812
A User-Configurable Smartwatch as a Point-of-Care Testing Device for Electrochemical Biosensors
The paper presents the development of a wristwatch as a configurable testing platform for personalized point-of-care testing. The developed watch can perform voltammetry and amperometry in a wide operating range, thus making the system capable of detecting various bio-analytes. This overcomes a major limitation of the existing meters available in the market, where each sensor requires a dedicated meter. The user selects the desired biomolecule for quantification on the smartphone using the developed Android mobile application. The test parameters are transferred via Bluetooth, and the smartwatch is tuned to the chosen sensor. As a proof-of-concept, we have developed electrochemical biosensors for testing clinically significant biomolecules like glucose, uric acid and ascorbic acid, which was then interfaced with the smartwatch for the on-demand quantification. Using an ADC with 12-bit resolution, the device demonstrated a high resolution of 0.732 mV. The smartwatch could overcome the limitation associated with the quantification of uric acid in the presence of ascorbic acid by doing baseline subtraction, and the results show a low relative standard deviation of 4%. The glucose analysis was highly reproducible with a relative standard deviation of 4.95%, with a high resolution of 0.0217 mg dL -1 , and the results could be obtained within 5 s. The results obtained using the smartwatch were in excellent conformity with those obtained from a laboratory electrochemical workstation. The key advantage of the device is that it can be easily configured to test any new biomarkers without any hardware change by over-the-air mobile application updates.
- 26 October 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 287 (Pt 1) , 122045
A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample
- 26 October 2022
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 287 (Pt 1) , 122045
A paper-based point-of-care testing device for the colourimetric estimation of bilirubin in blood sample