Ariadna Schuck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ariadna Schuck has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Yong-Sang Kim
Sungkyunkwan University
4 shared publications Hyo Eun Kim
2 shared publications- Min-Kyung Shin
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
2 shared publications - Minhee Kang
Biomedical Engineering Research Center, Smart Healthcare Research Institute, Samsung Medical Center, Seoul, Republic of Korea
2 shared publications - Doo Ryeon Chung
Division of Infectious Diseases, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
1 shared publication - Hwarim Im
Department of Electrical and Electronics Engineering, Konkuk University, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 17 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 510
Electrochemical Analysis of Amyloid Plaques and ApoE4 with Chitosan-Coated Gold Nanostars for Alzheimer’s Detection
Monitoring the progression of Alzheimer’s disease (AD) is crucial for mitigating dementia symptoms, alleviating pain, and improving mobility. Traditionally, AD biomarkers like amyloid plaques are predominantly identified in cerebrospinal fluid (CSF) due to their concentrated presence. However, detecting these markers in blood is hindered by the blood–brain barrier (BBB), resulting in lower concentrations. To address this challenge and identify pertinent AD biomarkers—specifically amyloid plaques and apolipoprotein E4 (ApoE4)—in blood plasma, we propose an innovative approach. This involves enhancing a screen-printed carbon electrode (SPCE) with an immobilization matrix comprising gold nanostars (AuNSs) coated with chitosan. Morphological and electrical analyses confirmed superior dispersion and conductivity with 0.5% chitosan, supported by UV–Vis spectroscopy, cyclic voltammetry, and Nyquist plots. Subsequent clinical assays measured electrical responses to quantify amyloid-β 42 (Aβ42) (15.63–1000 pg/mL) and APoE4 levels (0.41 to 40 ng/mL) in human blood plasma samples. Differential pulse voltammetry (DPV) responses exhibited peak currents proportional to biomarker concentrations, demonstrating high linear correlations (0.985 for Aβ42 and 0.919 for APoE4) with minimal error bars. Cross-reactivity tests with mixed solutions of amyloid-β 40 (Aβ40), Aβ42, and ApoE4 indicated minimal interference between biomarkers (<3% variation), further confirming the high specificity of the developed sensor. Validation studies demonstrated a strong concurrence with the gold-standard enzyme-linked immunosorbent assay (ELISA), while interference tests indicated a minimal variation in peak currents. This improved device presents promising potential as a point-of-care system, offering a less invasive, cost-effective, and simplified approach to detecting and tracking the progression of AD. The substantial surface binding area further supports the efficacy of our method, offering a promising avenue for advancing AD diagnostics.
- 17 October 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (10) , 510
Open AccessElectrochemical Analysis of Amyloid Plaques and ApoE4 with Chitosan-Coated Gold Nanostars for Alzheimer’s Detection
Monitoring the progression of Alzheimer’s disease (AD) is crucial for mitigating dementia symptoms, alleviating pain, and improving mobility. Traditionally, AD biomarkers like amyloid plaques are predominantly identified in cerebrospinal fluid (CSF) due to their concentrated presence. However, detecting these markers in blood is hindered by the blood–brain barrier (BBB), resulting in lower concentrations. To address this challenge and identify pertinent AD biomarkers—specifically amyloid plaques and apolipoprotein E4 (ApoE4)—in blood plasma, we propose an innovative approach. This involves enhancing a screen-printed carbon electrode (SPCE) with an immobilization matrix comprising gold nanostars (AuNSs) coated with chitosan. Morphological and electrical analyses confirmed superior dispersion and conductivity with 0.5% chitosan, supported by UV–Vis spectroscopy, cyclic voltammetry, and Nyquist plots. Subsequent clinical assays measured electrical responses to quantify amyloid-β 42 (Aβ42) (15.63–1000 pg/mL) and APoE4 levels (0.41 to 40 ng/mL) in human blood plasma samples. Differential pulse voltammetry (DPV) responses exhibited peak currents proportional to biomarker concentrations, demonstrating high linear correlations (0.985 for Aβ42 and 0.919 for APoE4) with minimal error bars. Cross-reactivity tests with mixed solutions of amyloid-β 40 (Aβ40), Aβ42, and ApoE4 indicated minimal interference between biomarkers (<3% variation), further confirming the high specificity of the developed sensor. Validation studies demonstrated a strong concurrence with the gold-standard enzyme-linked immunosorbent assay (ELISA), while interference tests indicated a minimal variation in peak currents. This improved device presents promising potential as a point-of-care system, offering a less invasive, cost-effective, and simplified approach to detecting and tracking the progression of AD. The substantial surface binding area further supports the efficacy of our method, offering a promising avenue for advancing AD diagnostics.
- Open Access
- 8 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 91
Dual-Mode Graphene Field-Effect Transistor Biosensor with Isothermal Nucleic Acid Amplification
Despite a substantial increase in testing facilities during the pandemic, access remains a major obstacle, particularly in low-resource and remote areas. This constraint emphasizes the need for high-throughput potential point-of-care diagnostic tools in environments with limited resources. Loop-mediated isothermal amplification (LAMP) is a promising technique, but improvements in sensitivity are needed for accurate detection, especially in scenarios where the virus is present in low quantities. To achieve this objective, we present a highly sensitive detection approach of a dual-mode graphene-based field-effect transistor (G-FET) biosensor with LAMP. The G-FET biosensor, which has a transparent graphene microelectrode array on a glass substrate, detects LAMP products in less than 30 min using both observable color changes and Dirac point voltage measurements, even in samples with low viral concentrations. This dual-mode G-FET biosensor emerges as a potential alternative to conventional RT-PCR for severe acute respiratory syndrome-associated coronavirus (SARS-CoV)-2 detection or point-of-care testing, particularly in resource-constrained scenarios such as developing countries. Moreover, its capacity for colorimetric detection with the naked eye enhances its applicability in diverse settings.
- 8 February 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (2) , 91
Open AccessDual-Mode Graphene Field-Effect Transistor Biosensor with Isothermal Nucleic Acid Amplification
Despite a substantial increase in testing facilities during the pandemic, access remains a major obstacle, particularly in low-resource and remote areas. This constraint emphasizes the need for high-throughput potential point-of-care diagnostic tools in environments with limited resources. Loop-mediated isothermal amplification (LAMP) is a promising technique, but improvements in sensitivity are needed for accurate detection, especially in scenarios where the virus is present in low quantities. To achieve this objective, we present a highly sensitive detection approach of a dual-mode graphene-based field-effect transistor (G-FET) biosensor with LAMP. The G-FET biosensor, which has a transparent graphene microelectrode array on a glass substrate, detects LAMP products in less than 30 min using both observable color changes and Dirac point voltage measurements, even in samples with low viral concentrations. This dual-mode G-FET biosensor emerges as a potential alternative to conventional RT-PCR for severe acute respiratory syndrome-associated coronavirus (SARS-CoV)-2 detection or point-of-care testing, particularly in resource-constrained scenarios such as developing countries. Moreover, its capacity for colorimetric detection with the naked eye enhances its applicability in diverse settings.
- 1 January 2022
- Published by Elsevier in Microelectronics Reliability
- Vol. 128, 114442
Developed non-destructive verification methods for accelerated temperature cycling of power MOSFETs
- 1 January 2022
- Published by Elsevier in Microelectronics Reliability
- Vol. 128, 114442
Developed non-destructive verification methods for accelerated temperature cycling of power MOSFETs