Shuangquan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuangquan Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dugang Kang
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication - Lin Ma
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication - Shouliang Chen
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication - Wei Zhao
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication - Wenpin Zhang
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication - Yi Xu
Key Disciplines Lab of Novel Micro-Nano Devices and System Technology, Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Shapingba, Chongqing, 400044, China; School of Optoelectronics Engineering, Chongqing University, Shapingba, Chongqing, 400044, China
1 shared publication
Latest Publications
- Open Access
- 21 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 160
Integrated Microfluidic Chip Technology for Copper Ion Detection Using an All-Solid-State Ion-Selective Electrode
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. Additionally, a microfluidic chip for the ASS-ISE with copper was designed and prepared. An integrated microfluidic chip test system with an ASS-ISE was developed using a self-constructed potential detection device. The accuracy of the system was validated through comparison testing with atomic absorption spectrophotometry (AAS). The experimental findings indicate that the relative standard deviation (RSD) of the integrated ASS-ISE with the copper microfluidic chip test system is 4.54%, as compared to the industry standard method. This value complies with the stipulated requirement of an RSD ≤ 5% in DL/T 955-2016.
- 21 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 160
Open AccessIntegrated Microfluidic Chip Technology for Copper Ion Detection Using an All-Solid-State Ion-Selective Electrode
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. Additionally, a microfluidic chip for the ASS-ISE with copper was designed and prepared. An integrated microfluidic chip test system with an ASS-ISE was developed using a self-constructed potential detection device. The accuracy of the system was validated through comparison testing with atomic absorption spectrophotometry (AAS). The experimental findings indicate that the relative standard deviation (RSD) of the integrated ASS-ISE with the copper microfluidic chip test system is 4.54%, as compared to the industry standard method. This value complies with the stipulated requirement of an RSD ≤ 5% in DL/T 955-2016.