Tanmay Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tanmay Jain has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kusum Verma
Malaviya National Institute of Technology Jaipur
4 shared publications Debomita Ghosh
Department of Electrical and Electronics Engineering, Birla Institute of Technology, Mesra, Ranchi, India
1 shared publicationDusmanta Kumar Mohanta
Department of Electrical and Electronics Engineering, Birla Institute of Technology, Mesra, Ranchi, India
1 shared publication- Mahendra Bhadu
Electrical Engineering Department, Engineering College Bikaner, Rajasthan, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2025 (1)
An Integrated Approach for Multiarea Reliability Improvement With Risk‐Based Contingency Analysis and Optimal Load Curtailment
Line failures, particularly in the form of N ‐1 contingencies, are a significant cause of interruptions in power grids, negatively affecting system reliability. Effective risk‐based contingency analysis (RBCA) is essential in modern power systems to address increasing uncertainties and complexities. This paper proposes an RBCA framework that calculates the probabilistic risk index (RI) based on transmission line severity functions for single‐ and multiarea bulk power systems. The approach identifies critical transmission lines and least reliable buses, enabling utilization of load curtailment strategies. Meta‐heuristic techniques, particle swarm optimization (PSO), and gray wolf optimization (GWO), are employed for optimal load curtailment, achieving approximately 30% reduction in curtailed load compared to the analytical proportional load curtailment approach. The methods chosen for their robustness and ability to balance exploration and exploitation in various optimization problems provide practical insights for system operators to enhance reliability under diverse operating conditions. Furthermore, the study examines the impact of flexible thermal rating (FTR) on multiarea systems considering variations in weather conditions, and a comparison is drawn with the static thermal rating (STR) system. Key reliability indices, including EENS, EDNS, BPECI, MBPCI, and EIC , are determined and analyzed for the proposed study. The proposed approach benefits system operators in preventing outages and formulating contingency action plans and emphasizes the study’s contribution to ensuring a stable and reliable power supply which is critical for modern societal needs. The proposed approach has been tested and validated on IEEE 24 reliability test system (RTS).
- 1 January 2025
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2025 (1)
Open AccessAn Integrated Approach for Multiarea Reliability Improvement With Risk‐Based Contingency Analysis and Optimal Load Curtailment
Line failures, particularly in the form of N ‐1 contingencies, are a significant cause of interruptions in power grids, negatively affecting system reliability. Effective risk‐based contingency analysis (RBCA) is essential in modern power systems to address increasing uncertainties and complexities. This paper proposes an RBCA framework that calculates the probabilistic risk index (RI) based on transmission line severity functions for single‐ and multiarea bulk power systems. The approach identifies critical transmission lines and least reliable buses, enabling utilization of load curtailment strategies. Meta‐heuristic techniques, particle swarm optimization (PSO), and gray wolf optimization (GWO), are employed for optimal load curtailment, achieving approximately 30% reduction in curtailed load compared to the analytical proportional load curtailment approach. The methods chosen for their robustness and ability to balance exploration and exploitation in various optimization problems provide practical insights for system operators to enhance reliability under diverse operating conditions. Furthermore, the study examines the impact of flexible thermal rating (FTR) on multiarea systems considering variations in weather conditions, and a comparison is drawn with the static thermal rating (STR) system. Key reliability indices, including EENS, EDNS, BPECI, MBPCI, and EIC , are determined and analyzed for the proposed study. The proposed approach benefits system operators in preventing outages and formulating contingency action plans and emphasizes the study’s contribution to ensuring a stable and reliable power supply which is critical for modern societal needs. The proposed approach has been tested and validated on IEEE 24 reliability test system (RTS).
- Open Access
- 1 February 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-21
N − 1 Security Criteria Based Integrated Deterministic and Probabilistic Framework for Composite Power System Reliability
Unpredictable variations in load demand and unanticipated component failures are progressively impacting the operation of modern power systems, making system evaluation more stochastic in nature. Although deterministic approaches were formerly the norm for determining system status, probabilistic approaches have greatly improved the capacity to capture the stochastic behavior characteristic of power system operations. The presented work in the paper recommends the use of probabilistic modelling approaches with deterministic approaches, highlighting their crucial function in augmenting the reliability and security of contemporary power systems to unanticipated failures. In this paper, N1 security criteria based reliability of the composite power system (CPS) is proposed using an integrated deterministic and probabilistic framework (D-P) considering outage of the transmission line. For the deterministic approach (DA), line overloading on available lines is determined using the static security index (SSI). For the probabilistic approach (PA), reliability indices such as expected loss of power (ELOP), expected frequency of contingency (EFOC), expected loss of load (ELOL), probability of load curtailment (PLC), and expected duration of load curtailments (EDLC) are calculated. Further, for each contingency, a performance index is determined using both approaches to assess the severity of the contingency that occurred on the power system. Based on the N1 security criteria based reliability analysis using an integrated D-P framework, a credible critical set of transmission lines is obtained, which can serve as important information to system operators. The proposed techniques have been tested on IEEE 24 bus reliability test system (RTS).
- 1 February 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-21
Open AccessN − 1 Security Criteria Based Integrated Deterministic and Probabilistic Framework for Composite Power System Reliability
Unpredictable variations in load demand and unanticipated component failures are progressively impacting the operation of modern power systems, making system evaluation more stochastic in nature. Although deterministic approaches were formerly the norm for determining system status, probabilistic approaches have greatly improved the capacity to capture the stochastic behavior characteristic of power system operations. The presented work in the paper recommends the use of probabilistic modelling approaches with deterministic approaches, highlighting their crucial function in augmenting the reliability and security of contemporary power systems to unanticipated failures. In this paper, N1 security criteria based reliability of the composite power system (CPS) is proposed using an integrated deterministic and probabilistic framework (D-P) considering outage of the transmission line. For the deterministic approach (DA), line overloading on available lines is determined using the static security index (SSI). For the probabilistic approach (PA), reliability indices such as expected loss of power (ELOP), expected frequency of contingency (EFOC), expected loss of load (ELOL), probability of load curtailment (PLC), and expected duration of load curtailments (EDLC) are calculated. Further, for each contingency, a performance index is determined using both approaches to assess the severity of the contingency that occurred on the power system. Based on the N1 security criteria based reliability analysis using an integrated D-P framework, a credible critical set of transmission lines is obtained, which can serve as important information to system operators. The proposed techniques have been tested on IEEE 24 bus reliability test system (RTS).
- Top Cited Papers
- 14 January 2024
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 244
Reliability based computational model for stochastic unit commitment of a bulk power system integrated with volatile wind power
- 14 January 2024
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 244
Top Cited PapersReliability based computational model for stochastic unit commitment of a bulk power system integrated with volatile wind power
- Open Access
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 4 (1) , 1-14
Augmentation of situational awareness by fault passage indicators in distribution network incorporating network reconfiguration
Power distribution systems are profoundly inclined to disturbances like untimely switching of breakers & relays, sympathetic tripping, and uncertainties regarding fault location. Thus, system stability and reliability are greatly affected. In this way, situational awareness and system integrity are the crucial factors in developing power system security, as it empowers successful decision making & timely reaction by the operators to any disturbance and also maintaining continuity of power supply. This paper focuses on the enhancement of situational awareness by fault location through fault passage indicators (FPI) to improve nominal impedance-based methods in distribution networks. Also, the proposed method is validated by comparing it with Intelligent Electronic Device (IED) based fault location method. Further, simultaneous reconfiguration of the system is incorporated to maintain the continuity of supply. The analysis has been tested on IEEE 33 bus distribution system.
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 4 (1) , 1-14
Open AccessAugmentation of situational awareness by fault passage indicators in distribution network incorporating network reconfiguration
Power distribution systems are profoundly inclined to disturbances like untimely switching of breakers & relays, sympathetic tripping, and uncertainties regarding fault location. Thus, system stability and reliability are greatly affected. In this way, situational awareness and system integrity are the crucial factors in developing power system security, as it empowers successful decision making & timely reaction by the operators to any disturbance and also maintaining continuity of power supply. This paper focuses on the enhancement of situational awareness by fault location through fault passage indicators (FPI) to improve nominal impedance-based methods in distribution networks. Also, the proposed method is validated by comparing it with Intelligent Electronic Device (IED) based fault location method. Further, simultaneous reconfiguration of the system is incorporated to maintain the continuity of supply. The analysis has been tested on IEEE 33 bus distribution system.