Andrzej Zakręcki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrzej Zakręcki has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Śliż
3rd Department of Internal Medicine and Cardiology, Medical University of Warsaw, 04-749 Warsaw, Poland
3 shared publications - Jan Oleksiuk
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
3 shared publications - Kajetan Jeznach
Łukasiewicz Research Network–Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
3 shared publications - Krzysztof Zawalski
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
3 shared publications - Piotr Falkowski
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
3 shared publications - Piotr Kołodziejski
Łukasiewicz Research Network—Industrial Research Institute for Automation and Measurements PIAP, 02-486 Warsaw, Poland
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 13, e92898
Intelligent Robot-Aided, Task-Oriented Physiotherapy Method for Upper Limb Rehabilitation: Development and Usability Study
Background: Task-oriented rehabilitation supported by exoskeletons has the potential to increase therapy intensity, personalization, and accessibility. However, to achieve fully automatic treatment, robotized systems need to analyze therapy in a more complex way than only based on reference trajectories following. Objective: This study aimed to investigate the effects of an intelligent, context-aware control algorithm for an upper limb rehabilitation exoskeleton on patients’ musculoskeletal engagement, compared with constant-admittance robot-assisted therapy, and conventional physiotherapist-guided treatment. Methods: A single-session experimental study was conducted with 34 adult participants performing 6 activities of daily living under 3 therapy modes: robot-assisted therapy with constant admittance, robot-assisted therapy with an intelligent assist-as-needed algorithm, and physiotherapist-guided therapy. Muscle activity was assessed using surface electromyography of 8 upper limb muscle groups, while joint kinematics were recorded using inertial measurement units. Metrics included electromyography power, muscle activation time, joint range of motion, and Burst Duration Similarity Indices. Statistical comparisons were performed using the t test and the Mann-Whitney U test depending on data normality. Results: Results indicate that the intelligent control strategy engages the musculoskeletal system at least as effectively as constant-admittance control across all exercises. At the same time, more motion control is given to the patient, which is consistent with the principles of neuroplastic motor learning. Compared with physiotherapist-guided therapy, robot-assisted treatment with intelligent control elicited significantly higher and more consistent muscular engagement. Intelligent assistance also modified joint-level motion patterns by reducing compensatory movements, particularly in shoulder-elbow coupling, while maintaining functional task execution. Muscle activation timing patterns during intelligent robot-assisted therapy were more consistent with robotic control than with manual therapy, reflecting altered movement strategies. Conclusions: These findings demonstrate that context-aware, intelligent control in rehabilitation exoskeletons can promote active patient participation, reduce compensatory behaviors, and maintain physiologically meaningful muscle engagement. The proposed approach exceeds the results of recent similar studies, being a promising step toward effective, minimally supervised, and task-oriented rehabilitation.
- 1 September 2026
- Published by JMIR Publications Inc. in JMIR Rehabilitation and Assistive Technologies
- Vol. 13, e92898
Open AccessIntelligent Robot-Aided, Task-Oriented Physiotherapy Method for Upper Limb Rehabilitation: Development and Usability Study
Background: Task-oriented rehabilitation supported by exoskeletons has the potential to increase therapy intensity, personalization, and accessibility. However, to achieve fully automatic treatment, robotized systems need to analyze therapy in a more complex way than only based on reference trajectories following. Objective: This study aimed to investigate the effects of an intelligent, context-aware control algorithm for an upper limb rehabilitation exoskeleton on patients’ musculoskeletal engagement, compared with constant-admittance robot-assisted therapy, and conventional physiotherapist-guided treatment. Methods: A single-session experimental study was conducted with 34 adult participants performing 6 activities of daily living under 3 therapy modes: robot-assisted therapy with constant admittance, robot-assisted therapy with an intelligent assist-as-needed algorithm, and physiotherapist-guided therapy. Muscle activity was assessed using surface electromyography of 8 upper limb muscle groups, while joint kinematics were recorded using inertial measurement units. Metrics included electromyography power, muscle activation time, joint range of motion, and Burst Duration Similarity Indices. Statistical comparisons were performed using the t test and the Mann-Whitney U test depending on data normality. Results: Results indicate that the intelligent control strategy engages the musculoskeletal system at least as effectively as constant-admittance control across all exercises. At the same time, more motion control is given to the patient, which is consistent with the principles of neuroplastic motor learning. Compared with physiotherapist-guided therapy, robot-assisted treatment with intelligent control elicited significantly higher and more consistent muscular engagement. Intelligent assistance also modified joint-level motion patterns by reducing compensatory movements, particularly in shoulder-elbow coupling, while maintaining functional task execution. Muscle activation timing patterns during intelligent robot-assisted therapy were more consistent with robotic control than with manual therapy, reflecting altered movement strategies. Conclusions: These findings demonstrate that context-aware, intelligent control in rehabilitation exoskeletons can promote active patient participation, reduce compensatory behaviors, and maintain physiologically meaningful muscle engagement. The proposed approach exceeds the results of recent similar studies, being a promising step toward effective, minimally supervised, and task-oriented rehabilitation.
- Open Access
Measurement-Based Optimization of a Lightweight Upper-Extremity Rehabilitation Exoskeleton for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.
Open AccessMeasurement-Based Optimization of a Lightweight Upper-Extremity Rehabilitation Exoskeleton for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.
- Open Access
- 12 January 2026
- Published by MDPI AG in Preprints.org
Optimization-Based Design of a Lightweight Rehabilitation Exoskeleton of an Upper Extremity for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.
- 12 January 2026
- Published by MDPI AG in Preprints.org
Open AccessOptimization-Based Design of a Lightweight Rehabilitation Exoskeleton of an Upper Extremity for Task-Oriented Treatment
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.
- Open Access
Influence of Ageing and Post-Processing on the Mechanical and Aesthetic Stability of PA12-Based 3D-Printed Components for Medical Devices
This study investigates the mechanical performance of polyamide 12 (PA12) components fabricated using Selective Laser Sintering (SLS) and HP Multi Jet Fusion (HP MJF) technologies, with particular emphasis on the effects of DyeMansion post-processing techniques. The primary objective was to evaluate the long-term durability of additively manufactured parts intended for use in medical environments, with ageing simulated over a 12-month period. Experimental findings indicate that specimens produced via SLS exhibit superior resistance to physicochemical degradation processes compared with those manufactured using HP MJF. Moreover, industrial dyeing with the DM60 system was found to significantly contribute to the retention of mechanical properties over time. Notably, the SLS-processed PA2200 material demonstrated enhanced mechanical stability after 12 months, particularly in the dyed configuration. These results highlight the critical role of both manufacturing technology and post-processing strategies in ensuring the long-term reliability of PA12 components, especially in applications subject to stringent mechanical and environmental requirements, such as in the medical and industrial sectors.
Open AccessInfluence of Ageing and Post-Processing on the Mechanical and Aesthetic Stability of PA12-Based 3D-Printed Components for Medical Devices
This study investigates the mechanical performance of polyamide 12 (PA12) components fabricated using Selective Laser Sintering (SLS) and HP Multi Jet Fusion (HP MJF) technologies, with particular emphasis on the effects of DyeMansion post-processing techniques. The primary objective was to evaluate the long-term durability of additively manufactured parts intended for use in medical environments, with ageing simulated over a 12-month period. Experimental findings indicate that specimens produced via SLS exhibit superior resistance to physicochemical degradation processes compared with those manufactured using HP MJF. Moreover, industrial dyeing with the DM60 system was found to significantly contribute to the retention of mechanical properties over time. Notably, the SLS-processed PA2200 material demonstrated enhanced mechanical stability after 12 months, particularly in the dyed configuration. These results highlight the critical role of both manufacturing technology and post-processing strategies in ensuring the long-term reliability of PA12 components, especially in applications subject to stringent mechanical and environmental requirements, such as in the medical and industrial sectors.
- Open Access
- 28 March 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 55 (1) , 370-387
Mediprintic sp. z o.o.'s 3D printed forearm orthosis project stakeholder analysis.
Cel: Celem badań było wykonanie analizy interesariuszy dla projektu badawczo-rozwojowego firmy Mediprintic sp. z o.o. w celu potwierdzenia poprawnie zidentyfikowanych podmiotów do współpracy w ramach projektu 1.1.2 PARP Platformy Startowe. Metody: Do oceny wybranych interesariuszy wykorzystano: narzędzie do identyfikacji interesariuszy i ich interesów, narzędzie do identyfikacji znaczenia i wpływu interesariuszy, analiza ryzyka dla podjętych działań podmiotu realizującego projektu z interesariuszami wraz z ustaleniem niezbędnych wskaźników oceny osiągnięcia kamienia milowego. Wyniki: Na podstawie przeprowadzonych badań wyselekcjonowano 14 kluczowych interesariuszy dla pomyślności realizacji projektu, które mają istotne znaczenie aby firma Mediprintic sp. z o.o. mogła wprowadzić swój produkt na rynek medyczny. Omówienie: Przeprowadzenie analizy interesariuszy ułatwia proces decyzyjny dla kadry zarządczej w celu priorytetyzacji podejmowanych działań uwzględniając ryzyka współpracy z poszczególnym partnerami biznesowymi.
- 28 March 2024
- Published by Akademia Nauk Stosowanych WSGE im. A. De Gasperi w Józefowie in Journal of Modern Science
- Vol. 55 (1) , 370-387
Open AccessMediprintic sp. z o.o.'s 3D printed forearm orthosis project stakeholder analysis.
Cel: Celem badań było wykonanie analizy interesariuszy dla projektu badawczo-rozwojowego firmy Mediprintic sp. z o.o. w celu potwierdzenia poprawnie zidentyfikowanych podmiotów do współpracy w ramach projektu 1.1.2 PARP Platformy Startowe. Metody: Do oceny wybranych interesariuszy wykorzystano: narzędzie do identyfikacji interesariuszy i ich interesów, narzędzie do identyfikacji znaczenia i wpływu interesariuszy, analiza ryzyka dla podjętych działań podmiotu realizującego projektu z interesariuszami wraz z ustaleniem niezbędnych wskaźników oceny osiągnięcia kamienia milowego. Wyniki: Na podstawie przeprowadzonych badań wyselekcjonowano 14 kluczowych interesariuszy dla pomyślności realizacji projektu, które mają istotne znaczenie aby firma Mediprintic sp. z o.o. mogła wprowadzić swój produkt na rynek medyczny. Omówienie: Przeprowadzenie analizy interesariuszy ułatwia proces decyzyjny dla kadry zarządczej w celu priorytetyzacji podejmowanych działań uwzględniając ryzyka współpracy z poszczególnym partnerami biznesowymi.
- Open Access
Innovative Approaches to 3D Printing of PA12 Forearm Orthoses: A Comprehensive Analysis of Mechanical Properties and Production Efficiency
This research paper aims to explore the mechanical characteristics of polyamide PA12 (PA12) as a 3D material printed utilizing Selective Laser Sintering (SLS) and HP MultiJet Fusion (HP MJF) technologies in order to design and manufacture forearm orthoses. The study assessed the flowability of the materials used and compared the mechanical performance of PA12 with each other using tensile, flexure, and impact tests in five different fabrication orientations: X, Y, Z, tilted 45° XZ, and tilted 45° YZ. The results of the study provide, firstly—the data for testing the quality of the applied polyamide powder blend and, secondly—the data for the design of the orthosis geometry from the aspect of its strength parameters and the safety of construction. The mechanical parameters of SLS specimens had less variation than MJF specimens in a given orientation. The difference in tensile strength between the 3D printing technologies tested was 1.8%, and flexural strength was 4.7%. A process analysis of the forearm orthoses revealed that the HP MJF 5200 system had a higher weekly production capacity than the EOS P396 in a production variance based on obtaining maximum strength parameters and a variance based on maximizing economic efficiency. The results suggest that medical device manufacturers can use additive manufacturing technologies to produce prototypes and small-batch parts for medical applications. This paper pioneers using 3D printing technology with Powder Bed Fusion (PBF) methods in designing and manufacturing forearm orthoses as a low- to medium-volume product. The applied solution addresses the problem of medical device manufacturers with regard to the analysis of production costs and mechanical properties when using 3D printing for certified medical devices.
Open AccessInnovative Approaches to 3D Printing of PA12 Forearm Orthoses: A Comprehensive Analysis of Mechanical Properties and Production Efficiency
This research paper aims to explore the mechanical characteristics of polyamide PA12 (PA12) as a 3D material printed utilizing Selective Laser Sintering (SLS) and HP MultiJet Fusion (HP MJF) technologies in order to design and manufacture forearm orthoses. The study assessed the flowability of the materials used and compared the mechanical performance of PA12 with each other using tensile, flexure, and impact tests in five different fabrication orientations: X, Y, Z, tilted 45° XZ, and tilted 45° YZ. The results of the study provide, firstly—the data for testing the quality of the applied polyamide powder blend and, secondly—the data for the design of the orthosis geometry from the aspect of its strength parameters and the safety of construction. The mechanical parameters of SLS specimens had less variation than MJF specimens in a given orientation. The difference in tensile strength between the 3D printing technologies tested was 1.8%, and flexural strength was 4.7%. A process analysis of the forearm orthoses revealed that the HP MJF 5200 system had a higher weekly production capacity than the EOS P396 in a production variance based on obtaining maximum strength parameters and a variance based on maximizing economic efficiency. The results suggest that medical device manufacturers can use additive manufacturing technologies to produce prototypes and small-batch parts for medical applications. This paper pioneers using 3D printing technology with Powder Bed Fusion (PBF) methods in designing and manufacturing forearm orthoses as a low- to medium-volume product. The applied solution addresses the problem of medical device manufacturers with regard to the analysis of production costs and mechanical properties when using 3D printing for certified medical devices.