FMFansheng Meng

Fansheng Meng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fansheng Meng has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel AlN/Sc0.2Al0.8N-Based Piezoelectric Composite Thin-Film-Enabled Bioinspired Honeycomb MEMS Hydrophone

    by Fansheng Meng, Chaoshuai Zhang, Guojun Zhang, Renxin Wang, Changde He, Yuhua Yang, Jiangong Cui, Wendong Zhang, Licheng Jia

    An innovative design of a hydrophone based on a piezoelectric composite film of AlN/Sc0.2Al0.8N is presented. By designing a non-uniform composite sensitive layer, the dielectric loss and defect density are significantly reduced, while the high-voltage electrical characteristics of scandium-doped aluminum nitride are retained. X-ray diffraction analysis shows that the sensitive films have excellent crystal quality (FWHM is 0.34°). According to the standard underwater acoustic calibration test, the device exhibits full directivity with a minimum deviation of ±0.5 dB at 1 kHz frequency, sound pressure sensitivity of −162.9 dB (re: 1 V/μPa) and equivalent noise density of 46.1 dB (re: 1 μPa/√Hz). The experimental results show that the comprehensive performance of the piezoelectric heterostructure hydrophone meets the standard of commercial high-end hydrophones while maintaining mechanical stability, and provides a new solution for underwater acoustic sensing.


  • Open Access

    Performance-Enhanced Piezoelectric Micromachined Ultrasonic Transducers by PDMS Acoustic Lens Design

    by Licheng Jia, Yong Liang, Fansheng Meng, Guojun Zhang, Renxin Wang, Changde He, Yuhua Yang, Jiangong Cui, Wendong Zhang, Guoqiang Wu

    This paper delves into enhancing the performance of ScAlN-based Piezoelectric Micromachined Ultrasonic Transducers (PMUTs) through the implementation of Polydimethylsiloxane (PDMS) acoustic lenses. The PMUT, encapsulated in PDMS, underwent thorough characterization through the utilization of an industry-standard hydrophone calibration instrument. The experimental results showed that the ScAlN-based PMUT with the PDMS lenses achieved an impressive sensitivity of −160 dB (re: 1 V/μPa), an improvement of more than 8 dB compared to the PMUT with an equivalent PDMS film. There was a noticeable improvement in the −3 dB main lobe width within the frequency response when comparing the PMUT with PDMS encapsulation, both with and without lenses. The successful fabrication of high-performance PDMS lenses proved instrumental in significantly boosting the sensitivity of the PMUT. Comprehensive performance evaluations underscored that the designed PMUT in this investigation surpassed its counterparts reported in the literature and commercially available transducers. This encouraging outcome emphasizes its substantial potential for commercial applications.


  • Open Access

    A High-Resolution 3D Ultrasound Imaging System Oriented towards a Specific Application in Breast Cancer Detection Based on a 1 × 256 Ring Array

    by Junhui Zhang, Fei Wu, Fansheng Meng, Guojun Zhang, Renxin Wang, Yuhua Yang, Jiangong Cui, Changde He, Licheng Jia, Wendong Zhang

    This paper presents the design and development of a high-resolution 3D ultrasound imaging system based on a 1 × 256 piezoelectric ring array, achieving an accuracy of 0.1 mm in both ascending and descending modes. The system achieves an imaging spatial resolution of approximately 0.78 mm. A 256 × 32 cylindrical sensor array and a digital phantom of breast tissue were constructed using the k-Wave toolbox. The signal is acquired layer by layer using 3D acoustic time-domain simulation, resulting in the collection of data from each of the 32 layers. The 1 × 256 ring array moves on a vertical trajectory from the chest wall to the nipple at a constant speed. A data set was collected at intervals of 1.5 mm, resulting in a total of 32 data sets. Surface rendering and volume rendering algorithms were used to reconstruct 3D ultrasound images from the volume data obtained via simulation so that the smallest simulated reconstructed lesion had a diameter of 0.3 mm. The reconstructed three-dimensional image derived from the experimental data exhibits the contour of the breast model along with its internal mass. Reconstructable dimensions can be achieved up to approximately 0.78 mm. The feasibility of applying the system to 3D breast ultrasound imaging has been demonstrated, demonstrating its attributes of resolution, precision, and exceptional efficiency.