María Asunción Iborra-Bendicho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
María Asunción Iborra-Bendicho has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Adolfo de Salazar
Servicio de Microbiología, Hospital Universitario San Cecilio, Granada, Spain
1 shared publication - Alberto De La Iglesia1 shared publication
- Ana Fuentes
Servicio de Microbiología, Hospital Universitario Clínico San Cecilio, 18016 Granada, Spain
1 shared publication - Antonio Aguilera
Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, Spain
1 shared publication - Aurora García-Barrionuevo1 shared publication
- Carolina Freyre-Carrillo1 shared publication
Latest Publications
- Open Access
Assessment of Two Commercial Serological Assays for the Diagnosis and Post-Treatment Follow-Up of Strongyloidiasis in a Cohort of Patients with Chagas Disease
Strongyloidiasis is a neglected tropical disease that frequently coexists with Chagas disease (CD) among individuals from Latin America. Serology is increasingly used for the diagnosis and post-treatment follow-up of strongyloidiasis; however, comparative data on commercially available assays remain limited. We conducted a cross-sectional evaluation in a cohort of fifty-five patients with previously treated CD attending a Tropical Medicine Unit in Spain. All patients underwent serological screening for Strongyloides stercoralis using two commercial ELISA assays: the Strongyloides IgG ELISA kit (DRG Instruments GmbH) (DRG) and Anti-Strongyloides ELISA IgG (Euroimmun Medizinische Labordiagnostika AG) (Euroimmun). A composite reference standard defined infection as seropositivity in combination with eosinophil count (>0.5 × 103 eosinophils per µL) or seropositivity in both assays. Infected individuals received ivermectin and were reassessed one-year post-treatment. Thirty-seven patients (67.3%) met the criteria for strongyloidiasis. Concordance between the assays was substantial (κ = 0.80). According to the composite study definition, both assays identified most patients as infected. At one-year follow-up, significant reductions were observed in DRG and Euroimmun indexes, as well as in eosinophil count (all p < 0.001). Treatment response rates were 83.3% with DRG and 73.3% with Euroimmun. Both ELISA assays showed comparable performance in identifying patients at risk of strongyloidiasis and in monitoring serological response after ivermectin treatment, supporting their usefulness in the management of patients with CD and suspected strongyloidiasis. Routine serological screening should be considered in this high-risk population.
Open AccessAssessment of Two Commercial Serological Assays for the Diagnosis and Post-Treatment Follow-Up of Strongyloidiasis in a Cohort of Patients with Chagas Disease
Strongyloidiasis is a neglected tropical disease that frequently coexists with Chagas disease (CD) among individuals from Latin America. Serology is increasingly used for the diagnosis and post-treatment follow-up of strongyloidiasis; however, comparative data on commercially available assays remain limited. We conducted a cross-sectional evaluation in a cohort of fifty-five patients with previously treated CD attending a Tropical Medicine Unit in Spain. All patients underwent serological screening for Strongyloides stercoralis using two commercial ELISA assays: the Strongyloides IgG ELISA kit (DRG Instruments GmbH) (DRG) and Anti-Strongyloides ELISA IgG (Euroimmun Medizinische Labordiagnostika AG) (Euroimmun). A composite reference standard defined infection as seropositivity in combination with eosinophil count (>0.5 × 103 eosinophils per µL) or seropositivity in both assays. Infected individuals received ivermectin and were reassessed one-year post-treatment. Thirty-seven patients (67.3%) met the criteria for strongyloidiasis. Concordance between the assays was substantial (κ = 0.80). According to the composite study definition, both assays identified most patients as infected. At one-year follow-up, significant reductions were observed in DRG and Euroimmun indexes, as well as in eosinophil count (all p < 0.001). Treatment response rates were 83.3% with DRG and 73.3% with Euroimmun. Both ELISA assays showed comparable performance in identifying patients at risk of strongyloidiasis and in monitoring serological response after ivermectin treatment, supporting their usefulness in the management of patients with CD and suspected strongyloidiasis. Routine serological screening should be considered in this high-risk population.
- Open Access
- 1 February 2024
- Published by MDPI AG in Preprints.org
Assessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.
- 1 February 2024
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.