N. O. Patokov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
N. O. Patokov has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- A. A. Anikina
St. Petersburg State Electrotechnical University (LETI), St. Petersburg, Russia
1 shared publication G. O. Danilenko
St. Petersburg State Electrotechnical University (LETI), St. Petersburg, Russia
1 shared publication- Ivan A. Lamkin
Photonics Department, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
1 shared publication - Marina Pavlova
Photonics Department, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
1 shared publication - Sergey Tarasov
St. Petersburg State Electrotechnical University “LETI
1 shared publication
Latest Publications
- 1 April 2023
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 14 (2) , 587-590
Postoperative Control of Technological Parameters of the Ion Implantation Process by the Method of Capacitance–Voltage Characteristics
Experimental samples of single-crystal silicon with hole conductivity doped with boron (KDB-12) and with electronic conductivity doped with phosphorus (KEF-4.5) were studied using the C–V method of postoperative control. On the original KEF-4.5 and KDB-12 wafers, a dielectric layer of silicon dioxide SiO2 was grown. Next, the near-surface layer was doped with phosphorus or boron by ion implantation with the type of conductivity corresponding to the substrate. Postoperative control of the dose of impurity atoms embedded by ion implantation was carried out according to capacitance–voltage characteristics. The impurity distribution profiles for the same sample obtained at different points, as well as for different samples with the same implanted dose, differed slightly. The calculation of the dose of implanted ions and the relative error showed a high accuracy of control of the ion implantation process by measuring the capacitance–voltage characteristics. The relative measurement error when compared with the given dose did not exceed 10%. An error greater than 5% was observed for samples with an implanted ion dose close to the limiting dose detected by this method.
- 1 April 2023
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 14 (2) , 587-590
Postoperative Control of Technological Parameters of the Ion Implantation Process by the Method of Capacitance–Voltage Characteristics
Experimental samples of single-crystal silicon with hole conductivity doped with boron (KDB-12) and with electronic conductivity doped with phosphorus (KEF-4.5) were studied using the C–V method of postoperative control. On the original KEF-4.5 and KDB-12 wafers, a dielectric layer of silicon dioxide SiO2 was grown. Next, the near-surface layer was doped with phosphorus or boron by ion implantation with the type of conductivity corresponding to the substrate. Postoperative control of the dose of impurity atoms embedded by ion implantation was carried out according to capacitance–voltage characteristics. The impurity distribution profiles for the same sample obtained at different points, as well as for different samples with the same implanted dose, differed slightly. The calculation of the dose of implanted ions and the relative error showed a high accuracy of control of the ion implantation process by measuring the capacitance–voltage characteristics. The relative measurement error when compared with the given dose did not exceed 10%. An error greater than 5% was observed for samples with an implanted ion dose close to the limiting dose detected by this method.