DHDavid Haider

David Haider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Haider has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High Inductance Cryogenic Current Comparators for Beamlines

    by V. Tympel, F. Machalett, T. Stöhlker, L. Crescimbeni, T. Schönau, D. Haider, T. Sieber, M. Schwickert, F. Schmidl, P. Seidel, et al.

    The Cryogenic Current Comparator (CCC) for beamlines is designed for the non-destructive, highly sensitive, and absolute measurement of bunched (AC) and un-bunched (DC) beam current of charged particle in the nA range using the external magnetic field of the beam. Niobium based CCCs are running at the CERN-Antiproton Decelerator (beamline diameter of 100 mm) and are tested at the CRYRING@ESR. CCCs of the xD-series (extended dimension) can support the new facility for antiproton and ion research (FAIR) at GSI (Gesellschaft für Schwerionenforschung) in Darmstadt with a 150 mm beamline diameter. The large FAIR-Nb-CCC-xD has an inductance of 80 µH. An effective way to increase the sensitivity is to increase the inductance of the pickup coils. The two first CCCs of the new Sm-series (smart & small) have overall inductances of 200 and 300 µH. This work describes the individual development steps, starting with the superconducting pickup coils. For CCCs with a flux concentrating core in the pickup coil, the subsequent current noise of the CCC is determined by the cores parameter. On the basis of low-temperature L s R s -measurements on pickup coils, it is shown how the fluctuation–dissipation theorem (FDT) can be used to infer the current noise of the CCC. For the first time a white noise of 1 pA rms /√Hz could be achieved. A superconducting, meandering shield filters the circular magnetic field and suppresses interference fields. Through step-by-step setup and measurements, it follows how this affects CCC system parameters. Finally, it was possible to measure current impulses below 1 nA pp in the laboratory.

  • Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator

    by Nicolas Marsic, Wolfgang F. O. Muller, Volker Tympel, Thomas Stohlker, Max Stapelfeld, Frank Schmidl, Matthias Schmelz, Vyacheslav Zakosarenko, Ronny Stolz, David Haider, et al.

    This article studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g., when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this article also discusses the effect of mechanical vibrations on the CCC performance.

  • Application Driven Optimization of Cryogenic Current Comparators (CCC) for Beam Storage Rings

    by Max Stapelfeld, Frank Schmidl, Paul Seidel, S. Stuck, Volker Tympel, Thomas Stohlker, David Haider, Marcus Schwickert, Thomas Sieber, Matthias Schmelz, et al.

    Non-destructive measurements of nA beam currents in particle beam storage rings with a Cryogenic Current Comparator (CCC) are well established. The detection of beam currents with small amplitudes with a CCC in a storage ring demands a high slew rate which is caused by the rapid change of the beam current exceeding the operational limit of the SQUID in flux-locked loop mode. Previous solutions to increase the slew rate used a LCR first-order low-pass were a small resistor, unfortunately, dominated the current noise of the CCC. In this work we present a novel take by adding a second resonator into the CCC which in turn allows for higher resistances of the LCR low-pass and therefore lower thermal current noise. A second challenge connected with this CCC approach is the residual magnetization of the highly magnetic permeable core and the resulting shielding currents in the superconducting circuits of the CCC. The timing of a storage ring in the range of minutes opens a way to reduce these DC currents using a LR highpass filter. Using serial sub-micro ohm resistors time constants in the hour range can be achieved to improve the stability and performance of the CCC system.