Frank Schmidl
Research Subjects
Frank Schmidl has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Paul Seidel
Institut für Festkörperphysik, Friedrich-Schiller-Universität Jena, Jena, Germany
7 shared publications - David Haider
GSI Helmholtzzentrum fr Schwerionenforschung, Darmstadt, Germany
3 shared publications - Marcus Schwickert
GSI Helmholtzzentrum fr Schwerionenforschung, Darmstadt, Germany
3 shared publications - Matthias Schmelz
Leibniz-Institute of Photonic Technologies, Jena, Germany
3 shared publications - Ronny Stolz
Leibniz Institute of Photonic Technology
3 shared publications - Sabine Kellner
Low Temperature Physics Group, Institute of Solid State Physics, Friedrich Schiller University Jena, 07743 Jena, Germany
3 shared publications
Latest Publications
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
High Inductance Cryogenic Current Comparators for Beamlines
The Cryogenic Current Comparator (CCC) for beamlines is designed for the non-destructive, highly sensitive, and absolute measurement of bunched (AC) and un-bunched (DC) beam current of charged particle in the nA range using the external magnetic field of the beam. Niobium based CCCs are running at the CERN-Antiproton Decelerator (beamline diameter of 100 mm) and are tested at the CRYRING@ESR. CCCs of the xD-series (extended dimension) can support the new facility for antiproton and ion research (FAIR) at GSI (Gesellschaft für Schwerionenforschung) in Darmstadt with a 150 mm beamline diameter. The large FAIR-Nb-CCC-xD has an inductance of 80 µH. An effective way to increase the sensitivity is to increase the inductance of the pickup coils. The two first CCCs of the new Sm-series (smart & small) have overall inductances of 200 and 300 µH. This work describes the individual development steps, starting with the superconducting pickup coils. For CCCs with a flux concentrating core in the pickup coil, the subsequent current noise of the CCC is determined by the cores parameter. On the basis of low-temperature L s R s -measurements on pickup coils, it is shown how the fluctuation–dissipation theorem (FDT) can be used to infer the current noise of the CCC. For the first time a white noise of 1 pA rms /√Hz could be achieved. A superconducting, meandering shield filters the circular magnetic field and suppresses interference fields. Through step-by-step setup and measurements, it follows how this affects CCC system parameters. Finally, it was possible to measure current impulses below 1 nA pp in the laboratory.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-5
High Inductance Cryogenic Current Comparators for Beamlines
The Cryogenic Current Comparator (CCC) for beamlines is designed for the non-destructive, highly sensitive, and absolute measurement of bunched (AC) and un-bunched (DC) beam current of charged particle in the nA range using the external magnetic field of the beam. Niobium based CCCs are running at the CERN-Antiproton Decelerator (beamline diameter of 100 mm) and are tested at the CRYRING@ESR. CCCs of the xD-series (extended dimension) can support the new facility for antiproton and ion research (FAIR) at GSI (Gesellschaft für Schwerionenforschung) in Darmstadt with a 150 mm beamline diameter. The large FAIR-Nb-CCC-xD has an inductance of 80 µH. An effective way to increase the sensitivity is to increase the inductance of the pickup coils. The two first CCCs of the new Sm-series (smart & small) have overall inductances of 200 and 300 µH. This work describes the individual development steps, starting with the superconducting pickup coils. For CCCs with a flux concentrating core in the pickup coil, the subsequent current noise of the CCC is determined by the cores parameter. On the basis of low-temperature L s R s -measurements on pickup coils, it is shown how the fluctuation–dissipation theorem (FDT) can be used to infer the current noise of the CCC. For the first time a white noise of 1 pA rms /√Hz could be achieved. A superconducting, meandering shield filters the circular magnetic field and suppresses interference fields. Through step-by-step setup and measurements, it follows how this affects CCC system parameters. Finally, it was possible to measure current impulses below 1 nA pp in the laboratory.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (9) , 1-9
Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator
This article studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g., when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this article also discusses the effect of mechanical vibrations on the CCC performance.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (9) , 1-9
Influence of Mechanical Deformations on the Performance of a Coaxial Shield for a Cryogenic Current Comparator
This article studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g., when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this article also discusses the effect of mechanical vibrations on the CCC performance.
- Open Access
Formation of Solid Lubricants during High Temperature Tribology of Silver-Doped Molybdenum Nitride Coatings Deposited by dcMS and HIPIMS
The coating system MoN-Ag is an interesting candidate for industrial applications as a low friction coating at elevated temperatures, due to the formation of lubricous molybdenum oxides and silver molybdates. Film deposition was performed by high-power impulse magnetron sputtering and direct current magnetron sputtering. To facilitate a future transfer to industry Mo-Ag composite targets have been sputtered in Ar/N2 atmosphere. The chemical composition of the deposited MoN-Ag films has been investigated by wavelength dispersive X-ray spectroscopy. Morphology and crystallographic phases of the films were studied by scanning electron microscopy and X-ray diffraction. To obtain film hardness in relation to Ag content and bias voltage, the instrumented indentation test was applied. Pin-on-disc tribological tests have been performed at room temperature and at high temperature (HT, 450 °C). Samples from HT tests have been analyzed by Raman measurements to identify possible molybdenum oxide and/or silver molybdate phases. At low Ag contents (≤7 at.%), coatings with a hardness of 18–31 GPa could be deposited. Friction coefficients at HT decreased with increasing Ag content. After these tests, Raman measurements revealed the MoO3 phase on all samples and the Ag2Mo4O13 phase for the highest Ag contents (~23–26 at.%).
Open AccessFormation of Solid Lubricants during High Temperature Tribology of Silver-Doped Molybdenum Nitride Coatings Deposited by dcMS and HIPIMS
The coating system MoN-Ag is an interesting candidate for industrial applications as a low friction coating at elevated temperatures, due to the formation of lubricous molybdenum oxides and silver molybdates. Film deposition was performed by high-power impulse magnetron sputtering and direct current magnetron sputtering. To facilitate a future transfer to industry Mo-Ag composite targets have been sputtered in Ar/N2 atmosphere. The chemical composition of the deposited MoN-Ag films has been investigated by wavelength dispersive X-ray spectroscopy. Morphology and crystallographic phases of the films were studied by scanning electron microscopy and X-ray diffraction. To obtain film hardness in relation to Ag content and bias voltage, the instrumented indentation test was applied. Pin-on-disc tribological tests have been performed at room temperature and at high temperature (HT, 450 °C). Samples from HT tests have been analyzed by Raman measurements to identify possible molybdenum oxide and/or silver molybdate phases. At low Ag contents (≤7 at.%), coatings with a hardness of 18–31 GPa could be deposited. Friction coefficients at HT decreased with increasing Ag content. After these tests, Raman measurements revealed the MoO3 phase on all samples and the Ag2Mo4O13 phase for the highest Ag contents (~23–26 at.%).
- 11 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Influence of Varying Gold Nanoparticle Distributions on Structural and Superconducting Properties of Thin YBCO Films
Artificial pinning centers based on crystalline gold nanoparticles inside a YBCO matrix are rarely researched so far. Nonetheless we obtained quite promising results by incorporating such particles in superconducting films. Critical current densities of 10 MA/cm2 at 77 K were observed by using small amounts of pinning material (less than 10 vol.%). Generation of gold nanoparticle ensemble inside a YBCO layer is a self-organized process. It takes place while superconductor deposition on a prior deposited gold seed layer. Particle sizes smaller 10 nm as well as some particles around 100 nm were observed. The positive effect on superconducting properties is known from previous investigations but especially the increase in critical current density observed so far is subject to greater fluctuations. In this work various nanoparticle ensembles were investigated directly by use of focus ion beam technique (FIB), scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) in well-defined areas with known local current density. This investigation provides a direct link between gold distribution and the resulting enhancement, which can be utilized to optimise process conditions in direction of favourable particle ensembles.
- 11 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Influence of Varying Gold Nanoparticle Distributions on Structural and Superconducting Properties of Thin YBCO Films
Artificial pinning centers based on crystalline gold nanoparticles inside a YBCO matrix are rarely researched so far. Nonetheless we obtained quite promising results by incorporating such particles in superconducting films. Critical current densities of 10 MA/cm2 at 77 K were observed by using small amounts of pinning material (less than 10 vol.%). Generation of gold nanoparticle ensemble inside a YBCO layer is a self-organized process. It takes place while superconductor deposition on a prior deposited gold seed layer. Particle sizes smaller 10 nm as well as some particles around 100 nm were observed. The positive effect on superconducting properties is known from previous investigations but especially the increase in critical current density observed so far is subject to greater fluctuations. In this work various nanoparticle ensembles were investigated directly by use of focus ion beam technique (FIB), scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) in well-defined areas with known local current density. This investigation provides a direct link between gold distribution and the resulting enhancement, which can be utilized to optimise process conditions in direction of favourable particle ensembles.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Application Driven Optimization of Cryogenic Current Comparators (CCC) for Beam Storage Rings
Non-destructive measurements of nA beam currents in particle beam storage rings with a Cryogenic Current Comparator (CCC) are well established. The detection of beam currents with small amplitudes with a CCC in a storage ring demands a high slew rate which is caused by the rapid change of the beam current exceeding the operational limit of the SQUID in flux-locked loop mode. Previous solutions to increase the slew rate used a LCR first-order low-pass were a small resistor, unfortunately, dominated the current noise of the CCC. In this work we present a novel take by adding a second resonator into the CCC which in turn allows for higher resistances of the LCR low-pass and therefore lower thermal current noise. A second challenge connected with this CCC approach is the residual magnetization of the highly magnetic permeable core and the resulting shielding currents in the superconducting circuits of the CCC. The timing of a storage ring in the range of minutes opens a way to reduce these DC currents using a LR highpass filter. Using serial sub-micro ohm resistors time constants in the hour range can be achieved to improve the stability and performance of the CCC system.
- 9 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-4
Application Driven Optimization of Cryogenic Current Comparators (CCC) for Beam Storage Rings
Non-destructive measurements of nA beam currents in particle beam storage rings with a Cryogenic Current Comparator (CCC) are well established. The detection of beam currents with small amplitudes with a CCC in a storage ring demands a high slew rate which is caused by the rapid change of the beam current exceeding the operational limit of the SQUID in flux-locked loop mode. Previous solutions to increase the slew rate used a LCR first-order low-pass were a small resistor, unfortunately, dominated the current noise of the CCC. In this work we present a novel take by adding a second resonator into the CCC which in turn allows for higher resistances of the LCR low-pass and therefore lower thermal current noise. A second challenge connected with this CCC approach is the residual magnetization of the highly magnetic permeable core and the resulting shielding currents in the superconducting circuits of the CCC. The timing of a storage ring in the range of minutes opens a way to reduce these DC currents using a LR highpass filter. Using serial sub-micro ohm resistors time constants in the hour range can be achieved to improve the stability and performance of the CCC system.
- Open Access
- 1 November 2013
- Published by IOP Publishing in New Journal of Physics
- Vol. 15 (11) , 113029
Gold nanocrystals in high-temperature superconducting films: creation of pinning patterns of choice
- 1 November 2013
- Published by IOP Publishing in New Journal of Physics
- Vol. 15 (11) , 113029
Open AccessGold nanocrystals in high-temperature superconducting films: creation of pinning patterns of choice
- Open Access
- 1 November 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 248, 012038
Experimental and theoretical investigation on high-Tc superconducting intrinsic Josephson junctions
- 1 November 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 248, 012038
Open AccessExperimental and theoretical investigation on high-Tc superconducting intrinsic Josephson junctions
- Open Access
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97, 012039
Operation of a high-Tc DC-SQUID-gradiometer on a non-metallic pulse tube refrigerator
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97, 012039
Open AccessOperation of a high-Tc DC-SQUID-gradiometer on a non-metallic pulse tube refrigerator
- 1 September 2007
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 460-462, 331-334
Noise properties of high-temperature superconducting dc-SQUID gradiometers
- 1 September 2007
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 460-462, 331-334
Noise properties of high-temperature superconducting dc-SQUID gradiometers
- 1 March 1998
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 11 (3) , 315-321
Planar gradiometers with high- DC SQUIDs for non-destructive testing
- 1 March 1998
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 11 (3) , 315-321
Planar gradiometers with high- DC SQUIDs for non-destructive testing