JHJialong Hou

Jialong Hou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jialong Hou has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • FBi_DRE: A fast bidirectional dynamic range expansion scheme for fringe projection profilometry in practical scenes

    by Minghao Lu, Long Qin, Jialong Hou, Zhiqiang Zhu, Changyan Xiao, Wei Huang, Yaonan Wang

  • JS-RegNeXt: A ConvNeXt-based few-shot JSR framework with correlation awareness and multi-scale prediction consistency

    by Teng Li, Runing Xiao, Tongtong Xie, Wei Huang, Jialong Hou, Yuchuan Qiao, Changyan Xiao

    Conventional label-constrained (LC) medical image registration methods are extremely dependent on the number of labels, resulting in the overfitting problem when the number of labels is insufficient. Recently, joint segmentation and registration (JSR) methods have demonstrated promising results for the LC registration tasks in few-shot situations. However, these methods typically lack global correlation awareness of the images to be registered and cannot robustly perceive global semantic information, leading to suboptimal registration performance on anatomy with low contrast or blurred boundaries. Therefore, we propose a novel JS-RegNeXt framework for few-shot label-constrained registration for medical images, which consists of segmentation and registration modules. Specifically, the segmentation module perceives global semantic information, and the registration module generates synthetic labeled data to fine-tune it. For the segmentation module, a SegNet with multi-scale prediction consistency is designed to mitigate the uncertainty introduced by synthesized data and to improve the robustness of semantic perception, even in low-contrast regions. For the registration module, a RegNeXt is proposed to achieve correlation awareness between images and leverages the large receptive field of ConvNeXt to enhance global perception. This design improves robustness in low-contrast regions, leading to more accurate and reliable image registration. Experiments on two public 3D medical image datasets, cardiac CT and brain MRI, show that our JS-RegNeXt achieves improvements in both segmentation and registration tasks compared to many state-of-the-art methods. It demonstrates that our JS-RegNeXt framework has great potential for clinical application.

  • A Boundary-Guided Needle Localization Approach for MRI-Guided Robotic Interventions

    by Teng Li, Wenhui Zheng, Weirui Cai, Runing Xiao, Jialong Hou, Yuchuan Qiao, Yanding Qin, Changyan Xiao

    Accurate and rapid needle localization in three-dimensional (3D) magnetic resonance images is critical for MRI-guided robotic interventions. However, the slim and slender shape of the needle, combined with the influence of the surrounding tissue interference, poses significant challenges to accurate needle tip localization. In this paper, we develop a real-time boundary-guided needle localization approach to improve the accuracy and efficiency of MRI-guided robotic interventions. To acquire the 2D MR slice images containing the entire needle, the Brown-Roberts-Wells frame is first utilized to automatically and quickly locate the two-dimensional (2D) needle plane in the 3D space. A novel boundary-guided segmentation network named BFine-Mask is then designed to segment the needle mask accurately with the guidance of the shape prior. Specifically, we design a balanced fine-grained feature pyramid network (BF-FPN) to better integrate multi-scale features and improve the representation of fine-grained boundary details. Additionally, a boundary feature branch is proposed to leverage shape information at the boundary to enhance segmentation accuracy in the tip region. Finally, a post-processing algorithm based on centerline detection is implemented to accurately locate the needle tip from the segmented mask. The proposed approach is thoroughly evaluated using a 15-gauge ceramic needle and a 14-gauge medical titanium needle in the pig brain and heart tissue phantoms with the guidance of a 5T MRI machine. In three different scenarios, our approach achieves average needle tip localization errors of 0.597 mm (1.01 pixels), 0.856 mm (1.45 pixels), and 0.590 mm (1.00 pixels). This approach achieves sub-millimeter positioning accuracy within one second, demonstrating its potential for future routine clinical applications.


  • An Adaptive Multiexposure Scheme for the Structured Light Profilometry of Highly Reflective Surfaces Using Complementary Binary Gray Code

    by Tianle Cheng, Long Qin, Yulong Li, Jialong Hou, Changyan Xiao

    The structured light profilometry often suffers from local overexposure and underexposure, resulting in measurement error while applied to highly reflective objects. To address this problem, we introduce an adaptive multiple exposure imaging and fusion scheme to generate desired decoding fringes even with the drastically varying reflective surface. Here, a complementary gray code is utilized in our profilometry to generate the projection stripes, and the responses from the binary positive and negative stripes are first exploited to define a unique image formation model for the structured light system. Based on the model, an optimal exposure sequence is calculated for a specific target using an adaptive mechanism, where the probing exposure is iteratively increased according to a prior difference threshold and some stop criterion. The projected stripes on the target surface are then captured at the optimal exposure time and the high dynamic range (HDR) images are generated by a specifically designed image fusion algorithm which is guided by the difference between the positive and negative stripes. Thus, these HDR response images could be decoded as the common gray code patterns to generate the 3D profile measurement. It is demonstrated in a comparative experiment using real workpieces that the proposed method could outperform the existing HDR methods in terms of accuracy and completeness of obtained profiles.