RXRuning Xiao

Runing Xiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Runing Xiao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • JS-RegNeXt: A ConvNeXt-based few-shot JSR framework with correlation awareness and multi-scale prediction consistency

    by Teng Li, Runing Xiao, Tongtong Xie, Wei Huang, Jialong Hou, Yuchuan Qiao, Changyan Xiao

    Conventional label-constrained (LC) medical image registration methods are extremely dependent on the number of labels, resulting in the overfitting problem when the number of labels is insufficient. Recently, joint segmentation and registration (JSR) methods have demonstrated promising results for the LC registration tasks in few-shot situations. However, these methods typically lack global correlation awareness of the images to be registered and cannot robustly perceive global semantic information, leading to suboptimal registration performance on anatomy with low contrast or blurred boundaries. Therefore, we propose a novel JS-RegNeXt framework for few-shot label-constrained registration for medical images, which consists of segmentation and registration modules. Specifically, the segmentation module perceives global semantic information, and the registration module generates synthetic labeled data to fine-tune it. For the segmentation module, a SegNet with multi-scale prediction consistency is designed to mitigate the uncertainty introduced by synthesized data and to improve the robustness of semantic perception, even in low-contrast regions. For the registration module, a RegNeXt is proposed to achieve correlation awareness between images and leverages the large receptive field of ConvNeXt to enhance global perception. This design improves robustness in low-contrast regions, leading to more accurate and reliable image registration. Experiments on two public 3D medical image datasets, cardiac CT and brain MRI, show that our JS-RegNeXt achieves improvements in both segmentation and registration tasks compared to many state-of-the-art methods. It demonstrates that our JS-RegNeXt framework has great potential for clinical application.

  • Open Access

    Learning-Based Hybrid Needle Tip Tracking and Visualization Framework for Robotic Ultrasound-Guided Interventions

    by Junling Fu, Zijian Cai, Runing Xiao, Giancarlo Ferrigno, Alberto Redaelli, Elena De Momi

    Ultrasound (US)-guided needle-based interventions have been extensively employed in clinical practice for biopsies, regional anesthesia, and tumor ablation, considering the advantages of real-time imaging, portability, and non-ionizing radiation. Precise localization and tracking of the needle tip are critical for ensuring the successful needle placement while minimizing the risk of injury to surrounding anatomical structures. However, achieving real-time and reliable needle tip tracking remains challenging due to the inherent properties of US images, such as low spatial resolution, speckle noise, and imaging artifacts that obscure the needle tip. This study proposes a hybrid learning-based framework for accurately and robustly localizing the needle tip within the US image plane during robot-assisted interventional procedures. The framework comprises a dual-branch template matching-based detection module, a Convolutional Neural Network (CNN)-based detection module, and a “dynamic template selection and updating" mechanism to enhance overall tracking performance. Additionally, to recover the needle tip invisibility caused by unanticipated movements, an active exploration strategy based on a Gaussian Process (GP) model and Bayesian Optimization (BO) is proposed for efficient and accurate robotic US probe pose adjustment. The effectiveness of the proposed method for needle tip tracking performance has been evaluated through a series of experiments conducted on ex vivo porcine liver samples under varying insertion angles and velocities. Experimental results demonstrate that the proposed framework achieves a maximum median localization error of 1.17 mm and an Interquartile Range (IQR) of 1.28 mm across all test conditions. Furthermore, in scenarios requiring needle tip visibility recovery, the proposed BO-based strategy achieved a median localization error of 1.52 mm and an IQR of 0.95 mm.


  • A Boundary-Guided Needle Localization Approach for MRI-Guided Robotic Interventions

    by Teng Li, Wenhui Zheng, Weirui Cai, Runing Xiao, Jialong Hou, Yuchuan Qiao, Yanding Qin, Changyan Xiao

    Accurate and rapid needle localization in three-dimensional (3D) magnetic resonance images is critical for MRI-guided robotic interventions. However, the slim and slender shape of the needle, combined with the influence of the surrounding tissue interference, poses significant challenges to accurate needle tip localization. In this paper, we develop a real-time boundary-guided needle localization approach to improve the accuracy and efficiency of MRI-guided robotic interventions. To acquire the 2D MR slice images containing the entire needle, the Brown-Roberts-Wells frame is first utilized to automatically and quickly locate the two-dimensional (2D) needle plane in the 3D space. A novel boundary-guided segmentation network named BFine-Mask is then designed to segment the needle mask accurately with the guidance of the shape prior. Specifically, we design a balanced fine-grained feature pyramid network (BF-FPN) to better integrate multi-scale features and improve the representation of fine-grained boundary details. Additionally, a boundary feature branch is proposed to leverage shape information at the boundary to enhance segmentation accuracy in the tip region. Finally, a post-processing algorithm based on centerline detection is implemented to accurately locate the needle tip from the segmented mask. The proposed approach is thoroughly evaluated using a 15-gauge ceramic needle and a 14-gauge medical titanium needle in the pig brain and heart tissue phantoms with the guidance of a 5T MRI machine. In three different scenarios, our approach achieves average needle tip localization errors of 0.597 mm (1.01 pixels), 0.856 mm (1.45 pixels), and 0.590 mm (1.00 pixels). This approach achieves sub-millimeter positioning accuracy within one second, demonstrating its potential for future routine clinical applications.


  • Cardiac dynamics compensation for intravascular ultrasound sequences

    by Runing Xiao, Wei Yu, Shengxian Tu

    Intravascular ultrasound (IVUS) is a well-established imaging technique for the assessment of coronary atherosclerotic plaque. IVUS has the ability to identify the arterial wall morphology, fibrous plaque locations and thicknesses, and internal lumen area. However, the motion of the imaging catheter with respect to the coronary wall caused by cardiac contraction during image acquisition impairs the subsequent visualization and quantification of IVUS image pullbacks. In this study, we propose a method to compensate for cardiac dynamics in IVUS. Keeping the original sensor field center origin unchanged, the vessel geometric centers are first extracted based on lumen segmentation. Subsequently, the periodic fluctuations of the geometric center sequence are used to formulate a heartbeat motion filtering algorithm based on the comb filter. Cardiac dynamics are then compensated by effectively filtering heartbeat deflection from both translational and rotational motion components. We evaluated 35 in vivo IVUS pullbacks and the experimental results showed an average percentage of artifact suppression of 77.82(± 7.55) %, demonstrating the reliability of the presented method in clinical cases. The method eliminates the need for image center correction and helps to maintain the original geometry of the vessel axes. Compared with existing methods, the presented method can more simply extract the heartbeat frequency and effectively filter out the higher order harmonic components of the heartbeat, resulting in more accurate cardiac dynamics compensation.