LRLitao Ruan

Litao Ruan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Litao Ruan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Active Tangential Electric Field Probe for Switching Noise Diagnosis in Power Modules

    by Zhiqiang Yi, Linyan Li, Shuaibing Guo, Zhanjun Huang, Litao Ruan, Hui Li, Zhizhe Wang, E. Shao, Yunlei Shi, Maning Zhang, et al.

    Wide-band-gap semiconductors have brought about a revolution in the speed of power electronic switching, but electromagnetic interference has become a new burden. In this paper, we present a tangential electric field probe dedicated to the diagnosis of power electron electromagnetic noise. The proposed probe adopts four-layer printed circuit board technology and can measure the Ex or Ey of the tangential electric field. The detection structure adopts enhanced dipole and differential amplifier with a 20 dB gain to improve the detection sensitivity. Through the measurement results, the proposed probe can operate from 100 kHz to 4.6 GHz, which is just right for power circuits. Its unwanted field suppression is above 10 dB, and maximum frequency response reach -25.8 dB at 0.65 GHz. The measurement results of a typical GaN power module demonstrate the effectiveness of the proposed probe.

  • Open Access

    Time-Domain Current Waveform Reconstruction of a Printed Trace via a Locally Enhanced Active H-Field Probing System

    by Zhiqiang Yi, Shuaibing Guo, Xiao Luo, Hui Li, Litao Ruan, Xinxin Tian, Weiheng Shao

    Time-domain current signal reconstruction is crucial for conducted electromagnetic interference measurements and signal diagnostics. Meanwhile, active magnetic field (H-field) probes significantly improve time-domain measurement sensitivity. This paper evaluates the effectiveness of the time-domain current waveform reconstruction technology on a printed trace via a locally enhanced active H-field probing system, and assesses algorithm accuracy and robustness by simulating the frequency response curves with different shapes. Comparative results demonstrate that the broadband reconstruction technology outperforms conventional integration methods in waveform fidelity when using the enhanced active H-field probe. The simulation results show that the broadband time-domain reconstruction technology can adapt to complex fluctuations in frequency response curve and provide relatively high-precision time-domain reconstruction results.

  • Calibration Based on De-Embedding for an Asymmetric Differential Magnetic Field Probing System

    by Litao Ruan, Weiheng Shao, Xinxin Tian, Hui Li, Shan Xue, Xin Cheng, Jianfeng Li

    Calibration of differential magnetic field probes is essential to ensure accuracy in near-field measurements. However, in practical applications, the asymmetry problem and the embedded part of the calibrator will affect the accuracy of broadband calibration. To address these challenges, a combined calibration method, termed the non-rotating de-embedding calibration method (NRDCM), is proposed for an asymmetric differential magnetic field probing system in this paper. The asymmetry problem of the differential magnetic field probing system is corrected by the proposed method. Furthermore, the attenuation and reflection introduced by the calibrators are also mitigated by a de-embedding process within the proposed method. Measurement results of the standing wave behavior demonstrate that NRDCM exhibits minimal fluctuation across a frequency range from 100 kHz to 20 GHz, confirming its suitability for asymmetric calibration applications up to 20 GHz.


  • Isolation Characterization for a Multicomponent Electromagnetic Near-Field Probing System

    by Weiheng Shao, Litao Ruan, Jinxin Zhang, Caixu Yu, Xinxin Tian

    Multicomponent electromagnetic probing system, which can detect multicomponents $E_{z}, H_{x}$ , and $H_{y}$ simultaneously, can achieve superior efficiency in nearfield measurement. However, as a typical multichannel measurement system, the isolation between any two measured signals in the multicomponent probing system is not clearly characterized. In this article, a comparative analysis on the isolation characterization methods for multiport multicomponent probing systems is conducted, employing both numerical simulations and experimental measurements. Meanwhile, a novel isolation characterization method is proposed based on the measurement of a two-port symmetric calibrator. Theoretically, by feeding the two-port symmetric calibrator with common mode and differential mode excitations, an ideal induction zone (IDZ), where unwanted field components are suppressed, is constructed for isolation characterization. Different isolation characterization methods are compared by using a typical multicomponent near-field probe, and measurement results demonstrate that the proposed common and differential modes excitation (CDME) method is more accurate, stable, and convenient.

  • A Middle Underfill L-Standard Design for Highly Impedance Continuity in Four-Port Probe De-Embedding Calibration

    by Zhanjun Huang, Hui Li, Litao Ruan, Xinxin Tian, Shan Xue, Jun Luo, Guoguang Lu, Zhizhe Wang, Weiheng Shao

    The calibration of the four-port three-component probe, measuring ${H}_{x}$ , ${H}_{y}$ , and ${E}_{z}$ , is interesting for near-field measurement. At high frequency, calibration errors caused by the frequency response are very distressing. These error reasons include the multiple refection caused by embedded part of the calibrator (first error term) and the single reflection caused by the probe approaching the calibrator (second error term). The first error term has been proven to be eliminated through de-embedding calibration method of two-port probe. However, the second error term cannot be removed by this method, which will cause the impedance discontinuity of calibration process. In this article, a middle underfill L-standard as a calibrator is proposed for a four-port three-component probe de-embedding calibration. The new L-standard design can increase the inductive reactance of transmission structure to resist the capacitive effect of the probe when approaching the calibrator. The results of simulation or measurement show that the new L-standard can improve the impedance continuity by nearly 75.6% with a suitable height. Compared with traditional embedding calibration method of four-port three-component probe, the frequency response after using the new calibrator can improve about $0.7\sim 2.2$ dB, and the ripples caused by embedded part can be eliminated.


  • A Virtual Network Matching Method for Correcting Asymmetric Near-Field Probing System

    by Weiheng Shao, Caixu Yu, Xinxin Tian, Zhanjun Huang, Wanqing Jing, Chengyang Luo, Litao Ruan, Yinghui Chen, Shan Xue, Duo-Long Wu

    In symmetric two-port probing system, the measured electromagnetic field signals can be decoupled. However, in practical application, asymmetric problem is difficult to avoid. So, correcting asymmetric probing system (APS) is significant to achieve ultra-wide-band near-field measurement. In this article, a virtual network matching method (VNMM) is proposed based on a circuit model, which is different from the previous asymmetric correction (or calibration) method. By setting up a virtual matching network, the APS is transformed into a virtual symmetric probing system (SPS), then the measured electromagnetic field signals can be decoupled. As a new forward correction method, the proposed VNMM is simpler and easier to use than the previous forward correction method. The measurement results of a two-port probing system in three asymmetric cases have verified the effectiveness of the VNMM, and a near-field scanning measurement proves the practical applicability of the VNMM. Furthermore, the VNMM can also be easily expanded to correct asymmetries of multiport probing systems.