LMLinhui Ma

Linhui Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linhui Ma has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An EMAT Guided Wave Tomography System for Gas–Liquid Two-Phase Flow Imaging

    by Fulu Liu, Yuedong Xie, Lijun Xu, Linhui Ma, Xiaofei Huang, Jun Long

    The gas-liquid two-phase flow tomography technique has significant value for industrial process monitoring. However, the harsh environment and metal pipes present a challenge that limits the applicability of existing techniques. To address the challenge of gas-liquid two-phase flow tomography in metal pipes, an ultrasonic tomography (UT) system based on electromagnetic acoustic transducer (EMAT) technology was designed and developed to effectively realize process tomography. By considering the installation distance, guided wave mode, and transducer coil proportion of the EMAT array, the optimal overall scheme of the EMAT array can be obtained through finite element (FE) simulation. Through experimental tests, the consistency of each channel of the EMAT array is evaluated and normalized in order to reduce the artefacts that are caused by channel inconsistency. In order to achieve tomography in metal pipes in static experiments, a revised total focusing method (TFM) algorithm has been developed within the UT system, utilising the EMAT guided wave. The analysis of the imaging effect and the sensitivity distribution in the imaging region has led to the formulation of proposals regarding the limitations of the system and potential improvement methods.


  • A Sensor Fusion Strategy to Compensate Lift-Off Noise for Eddy Current Testing

    by Jiyao Li, Yuedong Xie, Fulu Liu, Xiaofei Huang, Linhui Ma, Zhaoming Zhou, Lijun Xu

    Eddy Current Testing (ECT) has been extensively employed in non-destructive testing for the detection of defects. However, variations in lift-off distance of the ECT probe during inspections can lead to signal fluctuations that possibly obscure defect identification. To address this challenge, a novel lift-off suppression method utilizing an accelerometer-assisted sensing probe is proposed. The accelerometer integrated in the ECT probe measures the probe’s acceleration, allowing for lift-off distance estimation and further compensation. To further enhance this compensation, a Kalman filtering-based zero-lift-off updating algorithm is developed, improving the accuracy of lift-off distance estimations. Experimental results demonstrate a substantial reduction in lift-off noise, with average lift-off noise peak amplitudes reduced by 9.26 dB to 22.01 dB compared to raw signals. Additionally, the impact of excitation frequency on lift-off suppression performance and defect detection capability is investigated.


  • A Defects Detection Method of Buried Liquid-Filled Pipes Based on T(0,1) Guided Waves

    by Fulu Liu, Zhiying Li, Xiaofei Huang, Linhui Ma, Jiyao Li, Hang Pu, Jun Long, Lijun Xu, Yuedong Xie

    In this paper, we propose a method using T(0,1) guided waves combined with coil coding technique to detect defects in buried liquid-filled pipes implemented by an electromagnetic acoustic transducer (EMAT). Due to its non-dispersive properties and the fact that there is no energy loss in non-viscoelastic fluids, the T(0,1) mode is selected for pipe defects detection. The electromagnetic device that generates the circumferential magnetic field is optimized to excite the pure T(0,1) mode. To realize energy enhancement and defect location identification, the electromagnetic acoustic coil is spatially encoded by 11-bit Barker code and the receiver coil is multiplexed consisting of a spatial coded coil and a unit coil. The defect detection is accomplished through time-of-flight (TOF) time-frequency analysis, and the defect location identification is achieved by digital signal processing methods (cross-correlation and convolution). The feasibility of this method is verified by the finite element model and experimental analysis, indicating the defect locating error in a liquid-filled pipes is less than 1%. Overall, the proposed method achieves a high-precision flaw detection and location identification.