FEFathi Elashhab

Fathi Elashhab

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fathi Elashhab has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radiation-Induced Degradation of Guaran in Dilute Solution: Kinetics and Conformational Transition Under Ultra-Low-Dose X-Rays

    by Fathi Elashhab, Lobna Sheha, Tahani Alfazani

    This research presents an effective method for dilute aqueous guar gum (guaran) for specific applications. The Guaran solution (0.01 g.cm-3) was subjected to a range of atmospheric ultra-low-dose (ULD) X-ray irradiations, and changes in its molar mass were measured by viscometry. Kinetic analysis shows the process follows the first-order scission law with a high degradation rate constant of 0.243 kGy-1. The large radiation chemical yield (2.92X10-9 mol.J-1)) indicates the galactomannan backbone is very sensitive to indirect effects of water radiolysis. The temperature study reveals the activation energy for viscous flow falls from 4.20 to 2.13 kJ.mol-1 as the molar mass decreases from 4.20 to 2.13 kJ.mol-1. A consistently negative activation entropy points to a highly ordered transition state. Analysis using scaling laws gives a Mark-Houwink exponent (α) of 0.83 and a Flory exponent (ν) of 0.62, confirming the molecule has a self-avoiding random coil conformation during treatment. Moreover, the stable persistence length (lp ≈ 25-30 nm) suggests a reduction in hydrodynamic volume without changing the semi-flexible backbone. This clean, chemistry-free method, based on physical principles, offers an efficient way to produce functional, low-molecular-weight guaran for targeted drug delivery and as a prebiotic.

  • Open Access

    Solution Confirmation of UVC-Irradiated Low-Molecular-Weight Heparin

    by Fathi Elashhab, Lobna Sheha, Nada Elzawi

    Heparin is a highly sulphated polyelectrolyte, and its properties depend strongly on its shape in solution. In this study, we closely examined the structural behaviour of low-molecular-weight heparin under aerobic ultraviolet-C (UVC, 100–280 nm) radiation. Using controlled photodegradation, we prepared native, small, and ultra-small molar-mass fractions, enabling us to investigate how structural properties vary with molecular weight. We examined relationships among molar mass, radius of gyration, second virial coefficient, and critical overlap concentration to characterise different conformational states. Our results showed that as molar mass decreased, the chain diameter and persistence length also dropped, while the overlap concentration increased. This indicates a reduced hydrodynamic volume and increased chain flexibility. Positive second virial coefficient values indicate that polymer–solvent interactions remained favourable after photodegradation. The scaling exponents suggest that degraded heparin behaves as a semi-flexible polyelectrolyte and adopts an extended-coil shape in water with electrolytes. Further analysis showed that the characteristic ratio and chain stiffness decreased as chains were broken by irradiation. Overall, aerobic UVC irradiation provides a reliable way to modify the physical structure of these molecules while maintaining solution stability. These findings show a clear link between reduced molecular weight and changes in shape, which is useful for developing better low-molecular-weight heparins for several applications, including pharmaceutical and medical use.


  • Open Access

    Confirmation of Photo-Tailed Low-Molecular Weight Heparin

    by Fathi Elashhab, Lobna Sheha, Nada Elzawi

    Heparin is a highly sulfated polyelectrolyte, and its properties depend a lot on its shape in solution. In this study, we closely examined the structural behaviour of UVC-irradiated low-molecular-weight heparin. By using controlled photodegradation, we created native, small, and ultra-small molar mass fractions, which allowed us to study how structural properties change with molecular weight. We examined how molar mass, radius of gyration, second virial coefficient, and critical overlap concentration are related to one another to understand different conformational states. Our results showed that as molar mass decreased, the chain diameter and persistence length also dropped, while the overlap concentration increased. This means the hydrodynamic volume went down and the chains became more flexible. The positive second virial coefficient values showed that polymer–solvent interactions remained favourable after photo-tailing. The scaling exponents suggest that degraded heparin behaves as a semi-flexible polyelectrolyte and adopts an extended-coil shape in water with electrolytes. Further analysis showed that the characteristic ratio and stiffness of the chains decreased as the chains were broken by irradiation. Overall, UVC phototailing provides a reliable way to modify the structure of these molecules while maintaining solution stability. These findings show a clear link between reduced molecular weight and changes in shape, which is useful for developing better low-molecular-weight heparins for pharmaceutical and medical use.

  • Open Access

    Viscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution

    by Fathi Elashhab, Lobna Sheha, Nada Elzawi, Abdelsallam E. A. Youssef

    Gellan gum (Gellan), a versatile polysaccharide applied in gel formation and prebiotic formulations, is often processed to tailor its molecular properties. Previous studies employed gamma irradiation and chemical hydrolysis, though without addressing systematic scaling behavior. This study investigates the structural and conformational modifications of Gellan in dilute aqueous salt solutions using a safer and eco-friendly approach: atmospheric low-dose electron beam (e-beam) degradation coupled with viscosity analysis. Native and E-beam-treated Gellan samples (0.05 g/cm3 in 0.1 M KCl) were examined by relative viscosity at varying temperatures, with intrinsic viscosity and molar mass determined via Solomon–Ciuta and Mark–Houwink relations. Molar mass degradation followed first-order kinetics, yielding rate constants and degradation lifetimes. Structural parameters, including radius of gyration and second virial coefficient, produced scaling coefficients of 0.62 and 0.15, consistent with perturbed coil conformations in a good solvent. The shape factor confirmed preservation of an ideal random coil structure despite irradiation. Conformational flexibility was further analyzed using theoretical models. Transition state theory (TST) revealed that e-beam radiation lowered molar mass and activation energy but raised activation entropy, implying reduced flexibility alongside enhanced solvent interactions. The freely rotating chain (FRC) model estimated end-to-end distance (Rθ) and characteristic ratio (C∞), while the worm-like chain (WLC) model quantified persistence length (lp). Results indicated decreased Rθ, increased lp, and largely unchanged C∞, suggesting diminished chain flexibility without significant deviation from ideal coil behavior. Overall, this work provides new insights into Gellan’s scaling laws and flexibility under aerobic low-dose E-beam irradiation, with relevance for bioactive polysaccharide applications.


  • Open Access

    Viscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution

    by Fathi Elashhab, Lobna Sheha, Nada Elzawi, Abdelsallam Ea. Youssef

    This study explores the effect of E-beam radiation on gellan conformations in dilute aqueous solutions. Native and E-beam-modified gellan samples (N&EBMs) were prepared at 0.05 g/cm³ in 0.1M KCl under atmospheric conditions. Their relative viscosities were measured at different temperatures, and intrinsic viscosity and molar mass were determined using the Solomon–Ciuta and Mark-Houwink equations. The degradation of molar mass was analyzed, and first-order rate constants and degradation lifetimes were calculated. Structural properties such as the radius of gyration and second virial coefficient were evaluated, yielding scaling coefficients of 0.62 and 0.15, respectively, indicating that gellan chains adopt a perturbed coil structure in a good solvent. The shape parameter confirmed that E-beam radiation did not affect the ideal random coil structure of gellan. Chain flexibility was assessed using theoretical models, including the transition state theory (TST), freely rotating chain (FRC) model, and worm-like chain (WLC) model. According to TST, E-beam radiation reduced molar mass and activation energy while increasing activation entropy, decreasing chain flexibility but enhancing solvent quality. FRC model provided the end-to-end distance (R_θ) and characteristic ratio (C_∞), while WLC model determined the persistence length (l_p). E-beam radiation decreased R_θ and increased〖 l〗_p, suggesting reduced flexibility and improved solvent interactions. However, C_∞ remained largely unchanged, indicating that gellan retained its ideal chain structure despite radiation exposure. These findings offer insight into the structural and conformational changes in gellan under E-beam radiation, with implications for its rheological and functional properties.


  • Open Access

    Activation functions of photodegraded carboxymethyl cellulose in solution: Viscosity measurements

    by Fathi Elashhab, Lobna Sheha, Rasha Sheltami, Tahani Alfazani, Abdelsallam Youssef

    يستخدم كربوكسي ميثيل السليلوز (CMC) في العديد من التطبيقات المعرضة للضوء والإشعاع، مثل المنتجات الغذائية والطبية. يمكن أن يؤثر التعرض للفوتونات على خصائص CMC وسلوكها وبالتالي المنتجات. هدفنا الرئيسي هو دراسة علاقات اللزوجة النسبية/درجة الحرارة ل CMC المتكسر في محلول ملحي. تم استخدام طريقة تقنية التحلل الضوئي، وتم الحصول على البيانات بقياسات اللزوجة. حيث أدى الانخفاض في الكتلة الجزيئية والتركيز إلى انخفاض في لزوجة المحلول، بينما كان لدرجة الحرارة تأثير معاكس. ثم تم توضيح معاملات إيرينج كدوال التركيز والكتلة المولارية. زاد عامل المحتوى الحراري وعامل أرهينيوس مع زيادة التركيز والكتلة المولارية، بينما الانتروبيا انخفضت. تصرف CMC متعدد الإلكتروليت في المحاليل الملحية مثل البوليمرات في المحاليل المحايدة. كان لمحلول CMC المتحلل ضوئيًا جودة إذابة أفضل من المحلول الأصلي.