Abdelsallam E. A. Youssef
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdelsallam E. A. Youssef has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Fathi Elashhab
Chemistry Department, Faculty of Science, University of Benghazi, Benghazi P.O. Box 1308, Libya
3 shared publications - Lobna Sheha
Chemistry Department, Faculty of Science, University of Benghazi, Benghazi P.O. Box 1308, Libya
3 shared publications - Nada Elzawi
Chemistry Department, Faculty of Science, University of Benghazi, Benghazi P.O. Box 1308, Libya
2 shared publications - Rasha Sheltami
Chemistry Department, Faculty of Science, University of Benghazi
1 shared publication - Tahani Alfazani
Chemistry Department, Faculty of Science, University of Benghazi
1 shared publication
Latest Publications
- Open Access
Viscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution
Gellan gum (Gellan), a versatile polysaccharide applied in gel formation and prebiotic formulations, is often processed to tailor its molecular properties. Previous studies employed gamma irradiation and chemical hydrolysis, though without addressing systematic scaling behavior. This study investigates the structural and conformational modifications of Gellan in dilute aqueous salt solutions using a safer and eco-friendly approach: atmospheric low-dose electron beam (e-beam) degradation coupled with viscosity analysis. Native and E-beam-treated Gellan samples (0.05 g/cm3 in 0.1 M KCl) were examined by relative viscosity at varying temperatures, with intrinsic viscosity and molar mass determined via Solomon–Ciuta and Mark–Houwink relations. Molar mass degradation followed first-order kinetics, yielding rate constants and degradation lifetimes. Structural parameters, including radius of gyration and second virial coefficient, produced scaling coefficients of 0.62 and 0.15, consistent with perturbed coil conformations in a good solvent. The shape factor confirmed preservation of an ideal random coil structure despite irradiation. Conformational flexibility was further analyzed using theoretical models. Transition state theory (TST) revealed that e-beam radiation lowered molar mass and activation energy but raised activation entropy, implying reduced flexibility alongside enhanced solvent interactions. The freely rotating chain (FRC) model estimated end-to-end distance (Rθ) and characteristic ratio (C∞), while the worm-like chain (WLC) model quantified persistence length (lp). Results indicated decreased Rθ, increased lp, and largely unchanged C∞, suggesting diminished chain flexibility without significant deviation from ideal coil behavior. Overall, this work provides new insights into Gellan’s scaling laws and flexibility under aerobic low-dose E-beam irradiation, with relevance for bioactive polysaccharide applications.
Open AccessViscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution
Gellan gum (Gellan), a versatile polysaccharide applied in gel formation and prebiotic formulations, is often processed to tailor its molecular properties. Previous studies employed gamma irradiation and chemical hydrolysis, though without addressing systematic scaling behavior. This study investigates the structural and conformational modifications of Gellan in dilute aqueous salt solutions using a safer and eco-friendly approach: atmospheric low-dose electron beam (e-beam) degradation coupled with viscosity analysis. Native and E-beam-treated Gellan samples (0.05 g/cm3 in 0.1 M KCl) were examined by relative viscosity at varying temperatures, with intrinsic viscosity and molar mass determined via Solomon–Ciuta and Mark–Houwink relations. Molar mass degradation followed first-order kinetics, yielding rate constants and degradation lifetimes. Structural parameters, including radius of gyration and second virial coefficient, produced scaling coefficients of 0.62 and 0.15, consistent with perturbed coil conformations in a good solvent. The shape factor confirmed preservation of an ideal random coil structure despite irradiation. Conformational flexibility was further analyzed using theoretical models. Transition state theory (TST) revealed that e-beam radiation lowered molar mass and activation energy but raised activation entropy, implying reduced flexibility alongside enhanced solvent interactions. The freely rotating chain (FRC) model estimated end-to-end distance (Rθ) and characteristic ratio (C∞), while the worm-like chain (WLC) model quantified persistence length (lp). Results indicated decreased Rθ, increased lp, and largely unchanged C∞, suggesting diminished chain flexibility without significant deviation from ideal coil behavior. Overall, this work provides new insights into Gellan’s scaling laws and flexibility under aerobic low-dose E-beam irradiation, with relevance for bioactive polysaccharide applications.
- Open Access
- 30 July 2025
- Published by MDPI AG in Preprints.org
Viscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution
This study explores the effect of E-beam radiation on gellan conformations in dilute aqueous solutions. Native and E-beam-modified gellan samples (N&EBMs) were prepared at 0.05 g/cm³ in 0.1M KCl under atmospheric conditions. Their relative viscosities were measured at different temperatures, and intrinsic viscosity and molar mass were determined using the Solomon–Ciuta and Mark-Houwink equations. The degradation of molar mass was analyzed, and first-order rate constants and degradation lifetimes were calculated. Structural properties such as the radius of gyration and second virial coefficient were evaluated, yielding scaling coefficients of 0.62 and 0.15, respectively, indicating that gellan chains adopt a perturbed coil structure in a good solvent. The shape parameter confirmed that E-beam radiation did not affect the ideal random coil structure of gellan. Chain flexibility was assessed using theoretical models, including the transition state theory (TST), freely rotating chain (FRC) model, and worm-like chain (WLC) model. According to TST, E-beam radiation reduced molar mass and activation energy while increasing activation entropy, decreasing chain flexibility but enhancing solvent quality. FRC model provided the end-to-end distance (R_θ) and characteristic ratio (C_∞), while WLC model determined the persistence length (l_p). E-beam radiation decreased R_θ and increased〖 l〗_p, suggesting reduced flexibility and improved solvent interactions. However, C_∞ remained largely unchanged, indicating that gellan retained its ideal chain structure despite radiation exposure. These findings offer insight into the structural and conformational changes in gellan under E-beam radiation, with implications for its rheological and functional properties.
- 30 July 2025
- Published by MDPI AG in Preprints.org
Open AccessViscosity Analysis of Electron-Beam Degraded Gellan in Dilute Aqueous Solution
This study explores the effect of E-beam radiation on gellan conformations in dilute aqueous solutions. Native and E-beam-modified gellan samples (N&EBMs) were prepared at 0.05 g/cm³ in 0.1M KCl under atmospheric conditions. Their relative viscosities were measured at different temperatures, and intrinsic viscosity and molar mass were determined using the Solomon–Ciuta and Mark-Houwink equations. The degradation of molar mass was analyzed, and first-order rate constants and degradation lifetimes were calculated. Structural properties such as the radius of gyration and second virial coefficient were evaluated, yielding scaling coefficients of 0.62 and 0.15, respectively, indicating that gellan chains adopt a perturbed coil structure in a good solvent. The shape parameter confirmed that E-beam radiation did not affect the ideal random coil structure of gellan. Chain flexibility was assessed using theoretical models, including the transition state theory (TST), freely rotating chain (FRC) model, and worm-like chain (WLC) model. According to TST, E-beam radiation reduced molar mass and activation energy while increasing activation entropy, decreasing chain flexibility but enhancing solvent quality. FRC model provided the end-to-end distance (R_θ) and characteristic ratio (C_∞), while WLC model determined the persistence length (l_p). E-beam radiation decreased R_θ and increased〖 l〗_p, suggesting reduced flexibility and improved solvent interactions. However, C_∞ remained largely unchanged, indicating that gellan retained its ideal chain structure despite radiation exposure. These findings offer insight into the structural and conformational changes in gellan under E-beam radiation, with implications for its rheological and functional properties.
- Open Access
- 2 October 2023
- Published by Sebha University in Journal of Pure & Applied Sciences
- Vol. 22 (3) , 177-179
Activation functions of photodegraded carboxymethyl cellulose in solution: Viscosity measurements
يستخدم كربوكسي ميثيل السليلوز (CMC) في العديد من التطبيقات المعرضة للضوء والإشعاع، مثل المنتجات الغذائية والطبية. يمكن أن يؤثر التعرض للفوتونات على خصائص CMC وسلوكها وبالتالي المنتجات. هدفنا الرئيسي هو دراسة علاقات اللزوجة النسبية/درجة الحرارة ل CMC المتكسر في محلول ملحي. تم استخدام طريقة تقنية التحلل الضوئي، وتم الحصول على البيانات بقياسات اللزوجة. حيث أدى الانخفاض في الكتلة الجزيئية والتركيز إلى انخفاض في لزوجة المحلول، بينما كان لدرجة الحرارة تأثير معاكس. ثم تم توضيح معاملات إيرينج كدوال التركيز والكتلة المولارية. زاد عامل المحتوى الحراري وعامل أرهينيوس مع زيادة التركيز والكتلة المولارية، بينما الانتروبيا انخفضت. تصرف CMC متعدد الإلكتروليت في المحاليل الملحية مثل البوليمرات في المحاليل المحايدة. كان لمحلول CMC المتحلل ضوئيًا جودة إذابة أفضل من المحلول الأصلي.
- 2 October 2023
- Published by Sebha University in Journal of Pure & Applied Sciences
- Vol. 22 (3) , 177-179
Open AccessActivation functions of photodegraded carboxymethyl cellulose in solution: Viscosity measurements
يستخدم كربوكسي ميثيل السليلوز (CMC) في العديد من التطبيقات المعرضة للضوء والإشعاع، مثل المنتجات الغذائية والطبية. يمكن أن يؤثر التعرض للفوتونات على خصائص CMC وسلوكها وبالتالي المنتجات. هدفنا الرئيسي هو دراسة علاقات اللزوجة النسبية/درجة الحرارة ل CMC المتكسر في محلول ملحي. تم استخدام طريقة تقنية التحلل الضوئي، وتم الحصول على البيانات بقياسات اللزوجة. حيث أدى الانخفاض في الكتلة الجزيئية والتركيز إلى انخفاض في لزوجة المحلول، بينما كان لدرجة الحرارة تأثير معاكس. ثم تم توضيح معاملات إيرينج كدوال التركيز والكتلة المولارية. زاد عامل المحتوى الحراري وعامل أرهينيوس مع زيادة التركيز والكتلة المولارية، بينما الانتروبيا انخفضت. تصرف CMC متعدد الإلكتروليت في المحاليل الملحية مثل البوليمرات في المحاليل المحايدة. كان لمحلول CMC المتحلل ضوئيًا جودة إذابة أفضل من المحلول الأصلي.