YSYili Shen

Yili Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yili Shen has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A 32-Channel Neural-Recording Chip Achieving 117dB Intrinsic-CMRR and 100dB PSRR by CM-Tracking-Dynamic-Power-Rail and CM-Canceling-in-Idle-Phase Techniques

    by Yili Shen, Yekan Chen, Changgui Yang, Tingting He, Chaonan Yu, Jun Zhou, Yuxuan Luo, Kedi Xu, Gang Pan, Yunshan Zhang, et al.

    Multi-channel neural recording enables simultaneous monitoring of neuronal activities across multiple brain regions, while the in-vivo common-mode interference (CMI) significantly degrades the signal quality of implantable neural-recording chips. For a multi-channel neural-recording chip, the total common-mode rejection ratio (T-CMRR) of the analog front-end (AFE) is limited by the input imbalance between the signal electrode and the shared reference electrode, as well as the intrinsic CMRR (I-CMRR) of its circuits. The traditional common-mode replication (CM-REP) technique is only applicable to single-channel systems such as ECG monitoring devices. In addition, conventional pre-amplifier and frequency-controlled differential regulator (FCDR) techniques suffer from gain mismatch and high power consumption, respectively. To address these issues, this work presents a 32-channel neural-recording chip fabricated in a 65 nm CMOS process, which effectively suppresses the CMI in two operational modes: 1) In high-gain mode, the proposed CM-tracking-dynamic-power-rail (CM-TDPR) instrumentation amplifier (IA) achieves 50 GΩ CM input impedance, 117 dB I-CMRR, and 100 dB power supply rejection ratio (PSRR), resulting in a T-CMRR of 87 dB; 2) In low-gain mode, a CM-canceling-in-idle-phase (CM-CIP) technique is proposed to increase the I-CMRR to 102 dB and match the signal-reference input impedance, thereby achieving a 95 dB T-CMRR. In-vivo experiments were conducted on a Sprague-Dawley rat, successfully validating the CMRR performance of the proposed chip.

  • A Wireless Battery-Free Probe-Free Disposable Electrical-Digital-PCR Chip

    by Shijia Du, Yangfan Xuan, Yili Shen, Xin Xie, Weixiao Wang, Lianyi Xie, Cheng Han, Bo Zhao

    As the most fundamental and widely-used technique in molecular diagnostics, polymerase chain reaction (PCR) plays a crucial role across various applications including epidemic surveillance and medical diagnosis. For the numerous epidemics such as COVID-19, the massive and frequent detection has challenged the PCR equipment in system miniaturization and hardware cost efficiency as well as rapid and precise detection. In conventional methods, fluorescence-PCR requires huge costly optical instruments, and the DNA-Probe-PCR can only detect a corresponding sample. In addition, both the fluorescence-PCR and DNA-Probe-PCR suffer from complex pre-label or modification procedure, further increasing the fabrication cost. In this work, we demonstrate the first probe-free electrical-digital-PCR (EdPCR) chip based on impedance detection: 1) A sensor-on-circuit structure is proposed to replace the bulky costly optical instrument with a single CMOS chip, enabling the PCR equipment to be portable and disposable. 2) A harmonic-voting method is proposed to reduce the testing pixel error rate (PER). The system is implemented in 55nm CMOS process, and in-vitro PCR experiment is conducted in various samples. The on-chip sensing array of the proposed PCR chip achieves a pixel density of 1111 pixels/mm2, which is the highest in the state of the arts. Additionally, the proposed harmonic-voting method reduces the measured PER of impedance judgment by 35%, achieving an average PER of 12.2%.

  • A Battery-Free Neural Implant Achieving 6cm Reading Range and 36.2pJ/Bit Efficiency by PWM Passive Body-Channel Communication

    by Yili Shen, Changgui Yang, Weixiao Wang, Yunshan Zhang, Chaonan Yu, Kedi Xu, Gang Pan, Bo Zhao

    Minimally invasive wireless implants distributed in the nervous system can transfer various neural signals to an external device, offering an effective hardware tool for neuro-disorder monitoring. Battery-free wireless techniques based on wireless power transfer (WPT) have been adopted to minimize the neural implants, but the effective reading ranges of most conventional works are not long enough to access deep-tissue nerves. The existing ultrasonic coupling and binary-driven passive body-channel-communication (BCC) techniques extended the reading range but suffered from a low data rate and a high energy in wireless communication. In this work, we demonstrate a battery-free wireless neural implant based on the proposed pulse-width-modulation (PWM) passive-BCC technique, which improves the data rate and further reduces the energy per bit. The proposed technique is implemented in a neural-recording chip fabricated by a 65nm CMOS process. Measured results show that the proposed wireless neural implant achieves a battery-free reading range of 6cm, with an energy efficiency of 36.2pJ/bit. In-vivo experiment is performed in a Sprague-Dawley rat to record the neural signals wirelessly in a battery-free way.


  • A Wireless Battery-Free Cerebral-Oxygen-Monitoring Micro-System Featuring 0.21-mmHg Sensing Resolution

    by Weixiao Wang, Boyu Zhu, Yangfan Xuan, Yili Shen, Qijing Xiao, Zhiyu Wang, Yuxuan Luo, Gang Pan, Bin Su, Bo Zhao

    Cerebral oxygen reflects the oxidative metabolism in neurons, which can be monitored by detecting the partial pressure of oxygen (PO2) in brain, to evaluate various brain diseases such as traumatic brain injury (TBI) as well as study the brain activities in response to transient oxygenation changes. To continuously detect the cerebral oxygen of freely moving subjects, cerebral oxygen monitoring (COM) devices are required to be wireless, high resolution, and long lifetime. In conventional wireless PO2 sensors, the optical devices present a short lifetime due to the power-hungry LED driver, whereas the existing electrochemical sensors suffer from both a bulky battery and a low resolution. In this work, we propose two techniques to address the issues in conventional PO2 sensors: 1) a sensing-current-reuse technique is proposed to cut down the power of current-detection circuit, which eliminates the power-hungry trans-impedance amplifier (TIA) and current-mirror amplifier in conventional potentiostats and 2) a bipolar residual zoom-in (BRZ) technique is proposed to improve the current-sensing resolution with low power dissipation. The proposed wireless COM chip is fabricated in a 55-nm CMOS process, which is integrated with a self-designed electrochemical PO2 sensor. The measured results show that an in vitro sensing resolution of 0.21 mmHg in oxygen value is achieved by the proposed BRZ technique. In addition, the 25- $\mu $ W low power enables 2-m range battery-free telemetry based on wireless power transfer (WPT) and backscatter communication.


  • A 430- μ A 68.2-dB-SNR 133-dBSPL-AOP CMOS-MEMS Digital Microphone Based on Electrostatic Force Feedback Control

    by Jiaqi Dong, Qi Zhang, Xinwen Zhang, Yekan Chen, Yili Shen, Bo Zhao, Yuxuan Luo

    This article introduces a high-acoustic-dynamic-range and low-power digital microphone based on the electrostatic force feedback control (EFFC). The proposed design adjusts the sensitivity of the micro-electro-mechanical system (MEMS) by adaptively biasing it at different input amplitudes, thereby extending the dynamic range (DR). The proposed adaptive biasing technique allows the induced electrostatic force to function as a mechanical gain prior to the analog front end (AFE), consequently relaxing the noise performance requirements of the readout electronics. A capacitive feedback (CFB) instrumentation amplifier (IA) with an adjustable gain is employed to effectively reduce the thermal noise introduced by the feedback resistor in conventional resistive feedback (RFB) IAs. A sub-sampling amplitude detector (SSAD) composed of cascaded low-order decimation filters is proposed to achieve efficient acoustic volume detection. The detection results are used to control a fast-settling predictive reference charge pump (PRCP). The PRCP adopts a closed-loop architecture to achieve accurate adjustable bias voltage, with the proposed prediction logic to significantly reduce the settling time. The proposed system achieves a signal-to-noise ratio (SNR) of 68.2 dB at 94 dBSPL and an acoustic overload point (AOP) of 133 dBSPL, with a current consumption of 430 μA at a clock frequency of 3.072 MHz. The measured acoustic DR is 107.2 dB.

  • A Battery-Free Neural-Recording Chip Achieving 5.5 cm Fully-Implanted Depth by Galvanically-Switching Passive Body Channel Communication

    by Yili Shen, Changgui Yang, Yunshan Zhang, Weixiao Wang, Yuxuan Luo, Chaonan Yu, Kedi Xu, Gang Pan, Bo Zhao

    Wireless fully implanted devices are widely adopted for long-term neural-recording applications, where the cable-induced infection risk can be avoided. Battery-free communication based on wireless power transfer (WPT) can eliminate the battery to reduce the size of a wireless implant, realizing minimally invasive surgery. However, conventional battery-free implants suffer from a short communication range, such as inductive coupling, near-infrared (NIR) transmission, and active body-channel communication (BCC), which cannot apply to deep brain zones. Ultrasonic power transfer and communication benefit from a low channel loss, but the low carrier frequency leads to a low data rate, which is not able to transfer full-span neural signals such as spikes and multichannel signals. In this work, a galvanically-switching passive-BCC technique is proposed for neural implants, to extend the effective range of both power transfer and wireless communication. The brain tissue is utilized to form a galvanic loop for power delivery, while the neural-recording data switch the loop current to conduct passive BCC. The proposed technique is implemented in a neural recording chip fabricated in a 55-nm CMOS process. Through-tissue measurement shows that the chip realizes a battery-free communication range of 5.5 cm, with a bit-error rate (BER) of $4.4\ttimes10^{-6}$ . In the in-vivo demonstration, a 5.9-mm $^3$ flexible prototype with the proposed chip inside is fully implanted into a Sprague–Dawley rat, where the neural signals are read battery-free through the passive-BCC technique.


  • A 72-Channel Resistive-and-Capacitive Sensor-Interface Chip With Noise-Orthogonalizing and Pad-Sharing Techniques

    by Xiangdong Feng, Yuxuan Luo, Tianyi Cai, Yangfan Xuan, Yunshan Zhang, Yili Shen, Changgui Yang, Qijing Xiao, Sijun Du, Bo Zhao

    The growing trend of the Internet of Things (IoT) involves trillions of sensors in various applications. An extensive array of parameters need to be gathered concurrently with high-precision, low-cost, and low-power sensor nodes, such as resistive (R) and capacitive (C) sensors. Single-chip channel fusion can be an effective solution, while it is challenging to suppress the noise and integrate massive I/O pads. However, conventional oversampling noise-shaping methods increase power consumption, which fails to meet the demand of long-term monitoring applications. In addition, existing R/C sensor-interface chips require a pair of I/O pads for each sensor, where the pad frame dominates the overall chip area in massive-channel integration. In this work, we demonstrate a 72-channel R&C sensor-interface chip for proximity-and-temperature sensing. A noise-orthogonalizing technique is proposed to eliminate the quantization noise at the signal frequencies, achieving an energy efficiency of 19.1 pJ/step/channel. Moreover, a pad-sharing technique is proposed to reduce the number of I/O pads by half, enabling 72 sensors to be read by 36 pairs of I/O pads. The chip is fabricated by 65-nm CMOS technology, and measurement results show resolutions of 286 $\Omega $ and 162 fF, respectively. The power consumption and die area are reduced to 0.74 $\mu \text{W}$ /Channel and 0.038 mm2/Channel, respectively.