ASArjun Sapkota

Arjun Sapkota

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arjun Sapkota has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Large critical current density Josephson π -junctions with PdNi barriers

    by Arjun Sapkota, Pukar Sedai, Robert M. Klaes, Reza Loloee, Norman O. Birge, Nathan Satchell

    We report large π-state critical current densities, Jc(π), in Nb/Pd89Ni11/Nb Josephson junctions at Pd89Ni11 thicknesses near the first π-state. We observe oscillations in the critical current with ferromagnetic barrier thickness consistent with a 0–π transition. For a junction with a 9.4 nm Pd89Ni11 barrier, we obtain Jc(π)=410 kA/cm2 at 4.2 K, exceeding values reported in prior PdNi-based studies. Magnetization measurements on continuous films, together with coercivity tests on patterned arrays, confirm that Pd89Ni11 exhibits perpendicular magnetic anisotropy, enabling zero-field operation without magnetic initialization. The combination of large Jc(π) and intrinsic anisotropy establishes Pd89Ni11 as a promising barrier material for passive π-shifters in superconducting digital logic and qubit architectures.


  • Optimization of polycrystalline sputtered niobium thin films: The role of substrate and growth pressure

    by Pukar Sedai, Arjun Sapkota, Allison Avery, Kaylee I. Perez, Robert M. Klaes, Reza Loloee, Nathan Satchell

  • Open Access

    Computational modelling of a triaxial vibrating sample magnetometer

    by Leo Rodriguez, Arjun Sapkota, Jonathan Alvarado, Jitendra S. Tate, Wilhelmus J. Geerts

    Magnetic Field Assisted Additive Manufacturing (MFAAM) enables 3D printing of magnetic materials of various shapes which exhibit a complex anisotropy energy surface containing contributions generated from different origins such as sample, particle, and agglomerate shape anisotropy, flow and field induced anisotropy, and particle crystal anisotropy. These novel magnet shapes require the need to measure the x, y, and z components of the magnetic dipole moment simultaneously to fully understand the magnetic reversal mechanism and unravel the complex magnetic anisotropy energy surface of 3D printed magnetic composites. This work aims to develop a triaxial vibrating sample magnetometer (VSM) by adding a z-coil set to a pre-existing biaxial VSM employing a modified Mallison coil set. The optimum size and location of the sensing coils were determined by modeling the sensitivity matrix of the z-coil set. The designed coil set was implemented using 3D printed spools, a manual coil winder, and gauge 38 copper wire. A 3D printed strontium ferrite nylon composite sample was used to estimate the sensitivity of the z-coils (50 mV/emu). The results herein are applicable for any VSM using a modified Mallison biaxial coil configuration allowing for a quick implementation on pre-existing systems.


  • Open Access

    On the origin of systematic errors in VSM torque curves

    by Arjun Sapkota, Leo Rodriguez, Binod D. C., Kolton Dieckow, Chandan Q. Howlader, Wilhelmus J. Geerts, Jitendra Tate

    Magnetic anisotropy (MA) is a basic and crucial magnetic property which describes how the magnetic properties change with field angle in a magnetic composite. Torque measurements are normally used to measure a sample’s anisotropy constant and can be determined directly using a torque magnetometer (TM) or indirectly using a vibrating sample magnetometer (VSM). Most TM only operate at room temperature. However, a biaxial VSM allows straightforward torque measurements at varying temperatures. VSM torque curves comprise a 2θ background caused by small misalignments of the sample on the sample rod, and/or a non-azimuthal symmetric sample shape. These errors originate from the position dependence of the pickup coil sensitivity matrix. Here, the magnetic torque of a strontium ferrite/PA-12 3D printed samples was explored using biaxial VSM and compared to measurements done with a true torque magnetometer. Torque curves were taken from 16-22kOe every 2kOe on a 4.8 mm wire and a 1.23 mm dot sample using a MicroSense EZ9 VSM. Fourier analysis was used to determine the second harmonics from each torque curve. The biaxial torque curves of the wire samples have a much larger torque amplitude which is mainly due to the crosstalk of the y-coil set. Crosstalk originates from the non-azimuthal symmetric shape of the sample and due to the wobble originating from small sample misalignments on the sample rod. Background can be minimized by using samples with near cylindrical symmetry and using a microscope when mounting the sample on the sample rod.