MWMarkus Widorski

Markus Widorski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Markus Widorski has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and development of the P-cubed Target Insertion Device (P 3 -TID)

    by R. Mena-Andrade, J-L. Grenard, K. Guergar, R. Seidenbinder, M.I. Besana, B. Humann, G. Lavezzari, M. Widorski, A. Lechner, N. Vallis, et al.

    The P-cubed Target Insertion Device (P 3 -TID) is a research instrument dedicated to test novel positron source target configurations inside of the proof-of-principle PSI Positron Production (P-cubed or P 3 ) experiment at the Paul Scherrer Institute. The device allows an easy installation, positioning and replacement of different fixed targets. The present article describes its mechanical design at a detailed level.

  • Open Access

    Erratum to: Future Circular Collider Feasibility Study Report

    by M. Benedikt, F. Zimmermann, B. Auchmann, W. Bartmann, J. P. Burnet, C. Carli, A. Chancé, P. Craievich, M. Giovannozzi, C. Grojean, et al.

  • Radiation field characterization of the PSAIF irradiation facility at CERN

    by Claudia Ahdida, Hamza Boukabache, Clyde Laforge, Giuseppe Mazzola, Sarath Kundumattathil Mohanan, Paolo Pisano, Markus Widorski

  • Open Access

    Conversion coefficients for effective dose calculated using anthropomorphic mesh reference phantoms with the FLUKA code

    by Davide Bozzato, Francesco Cerutti, Robert Froeschl, Thomas Otto, Christian Theis, Vasilis Vlachoudis, Markus Widorski

    The mesh reference computational phantoms from ICRP Publication 145 have been implemented for the first time in the FLUKA Monte Carlo code. Conversion coefficients from particle fluence to effective dose E have been calculated with these mesh phantoms for an extended set of particles and energies, covering all relevant exposure scenarios, including those at high-energy accelerator facilities. The conversion coefficients were calculated for theoretical exposure conditions in the form of broad monoenergetic particle beams for the six irradiation geometries AP, PA, RLAT, LLAT, ROT, and ISO. The results are compared to those calculated with voxel phantoms from ICRP Publication 116 and with results recently computed with the Geant4 Monte Carlo code and the mesh phantoms for a smaller set of particles and energies. This work shows that the FLUKA code is capable of reliably calculating effective dose for a wide range of particles and energies with the most recent mesh phantoms of the ICRP. FLUKA is well suited to be used for effective dose calculations for the next general recommendations of the ICRP, expected for the early 2030s, in which mesh phantoms will supersede voxel phantoms.


  • Top Cited Papers
    Open Access

    Future Circular Collider Feasibility Study Report

    by M. Benedikt, F. Zimmermann, B. Auchmann, W. Bartmann, J. P. Burnet, C. Carli, A. Chancé, P. Craievich, M. Giovannozzi, C. Grojean, et al.

    Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.


  • Open Access

    Latest FLUKA developments

    by Gabrielle Hugo, Claudia Ahdida, Davide Bozzato, Daniele Calzolari, Francesco Cerutti, Alessia Ciccotelli, Anna Cimmino, Arnaud Devienne, Andre Donadon Servelle, Patrycja Dyrcz, et al.

    The FLUKA Monte Carlo code has recently undergone significant enhancements, driven by needs from its user community. Key improvements are discussed, such as a new point-wise treatment for the interactions of low-energy neutrons, the incorporation of a new model for nuclear elastic scattering of protons below 250 MeV, explicit generation of synchrotron radiation photons during charged particle tracking, a revised modeling approach for coherent effects in bent crystals, and the addition of arc-DPA scoring. While improving and extending FLUKA physics performance is essential, it is equally important to ensure the long-term maintainability of the codebase. This paper also outlines the strategy and substantial progress in evolving FLUKA to meet this objective. The FLUKA features are being translated into a new codebase, fulfilling essential criteria such as continuity in the user experience and compatibility with existing inputs, thus laying the foundation for a new FLUKA generation. The codebase makes use of the Geant4 toolkit when appropriate. Additionally, the enhanced collaboration with Geant4 has resulted in the development of an interface, detailed in this paper, that enables access to the FLUKA hadronic models from any Geant4 application.


  • Open Access

    30 Years of Electronics Evolution for CERN Safety Radiation Monitoring

    by Hamza Boukabache, Sarath Kundumattathil Mohanan, Gael Ducos, Clyde Laforge, Michel Pangallo, Daniel Perrin, Stefan Roesler, Markus Widorski, Doris Forkel-Wirth

    Radiation protection at CERN ensures a safe environment for the people working on site and for the general public by protecting against any unjustified exposure to ionizing radiation. One typical detector type used by the radiation monitoring system at CERN are ionization chambers. The ionizing radiation is detected by these sensors which produce a current proportional to the received radiation dose rate. The unavailability of commercial off-the-shelf (COTS) radiation monitoring systems which can fulfill our requirements was the driving force for undertaking in-house development of our own solution. The various systems developed in the Radiation Protection (RP) group of CERN are presented in this paper. The legacy systems and the latest generation of installed radiation monitors are all based on discrete components. The management of such complex systems with thousands of components is a herculean task and there is the unavoidable risk of obsolescence of components. The solution currently applied is the procurement and storage of components that may be required in the foreseeable future. This approach, although temporarily helping to mitigate the obsolescence problem, nonetheless renders any fault repair or upgrade cumbersome. Hence, an application specific integrated circuit (ASIC) development was initiated by the RP group. This paper presents the architecture of the readout section of three systems developed through 30 years of CERN operation before getting into the details of an in-house developed ASIC for radiation monitoring systems that provides state-of-the-art performance, as well as avoids dependency on COTS systems and components.

  • Open Access

    Ultra-Large Silicon Diode for Characterizing Low-Intensity Radiation Environments

    by Kacper Biłko, Rubén García Alía, Sylvain Girard, Mario Sacristan Barbero, Matteo Cecchetto, Camille Belanger-Champagne, Matteo Brucoli, Salvatore Danzeca, Alex Hands, Pedro Martín Holgado, et al.

    We present applications of a large commercial silicon diode (50 cm 2 x 500 um) for monitoring low-intensity radiation fields, together with benchmarks via Monte Carlo simulations. After the energy calibration with monoenergetic proton and alpha beams in the 2-8 MeV range, we show that the detector is capable of measuring atmospheric radiation at the ground level, not only in terms of a total number of events but also through their energy deposition distribution. Focusing on the atmospheric-like neutron spectrum, we prove that the diode detection cross-section is more than 5 orders of magnitude larger with respect to SRAM-based solutions, and highlight the potential use cases in the accelerator’s radiation environment.