Shohei Uranaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shohei Uranaka has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Ryuji Uemori
Research Center for Steel, Kyushu University
3 shared publications- Takuro Masumura
Department of Materials, Kyushu University
3 shared publications Takuya Maeda
Steel Research Laboratories, Nippon Steel Corporation
3 shared publications- Toshihiro Tsuchiyama
Department of Materials, Kyushu University
3 shared publications Hiroyuki Shirahata
Steel Research Laboratories, Nippon Steel Corporation
2 shared publicationsMisa Takanashi
Research Center for Steel, Kyushu University
2 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 112 (5) , 209-222
Evaluation of Solute Carbon Concentration in BCC Iron by Electrical Resistivity Measurement Considering Carbide Precipitation
Electrical resistivity measurement is a powerful method for evaluating the solute carbon concentration (Csol) in BCC iron. In this study, the effect of carbide precipitation on the accuracy of Csol quantification was examined by applying a model that predicts the electrical resistivity of composite microstructures containing dilute-dispersed spherical carbides. For Fe–C alloys with spheroidized cementite dispersed in ferrite, Csol in ferrite could be estimated with an uncertainty of only several tens of ppm. In Fe–0.2Mn–C alloys, high accuracy comparable to that of Fe–C alloys was achieved when Mn enrichment in ferrite accompanying cementite precipitation was properly taken into account. For Fe–2Mn–0.5Si–C martensitic alloys, Mn partitioning, dislocation annihilation, and grain coarsening do not occur during tempering at low-temperature below 573 K. Therefore, changes in electrical resistivity during tempering directly reflected the decrease in Csol, enabling accurate evaluation when the contribution of carbide precipitation was removed using the spherical dilute-dispersion model. In contrast, high-temperature tempering at 873 K induced pronounced Mn partitioning, and even slight uncertainties in the measured Mn concentration in ferrite led to errors of several hundred ppm in the estimated Csol. Although errors associated with volume fraction and electrical resistivity of carbides also affected the evaluation, their impact was much smaller than that of Mn partitioning. Consequently, except for the high-temperature-tempered Fe–2Mn–0.5Si–C alloy, the final accuracy of Csol measurement can be maintained within several tens of ppm when appropriate corrections are applied.
- 1 April 2026
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 112 (5) , 209-222
Open AccessEvaluation of Solute Carbon Concentration in BCC Iron by Electrical Resistivity Measurement Considering Carbide Precipitation
Electrical resistivity measurement is a powerful method for evaluating the solute carbon concentration (Csol) in BCC iron. In this study, the effect of carbide precipitation on the accuracy of Csol quantification was examined by applying a model that predicts the electrical resistivity of composite microstructures containing dilute-dispersed spherical carbides. For Fe–C alloys with spheroidized cementite dispersed in ferrite, Csol in ferrite could be estimated with an uncertainty of only several tens of ppm. In Fe–0.2Mn–C alloys, high accuracy comparable to that of Fe–C alloys was achieved when Mn enrichment in ferrite accompanying cementite precipitation was properly taken into account. For Fe–2Mn–0.5Si–C martensitic alloys, Mn partitioning, dislocation annihilation, and grain coarsening do not occur during tempering at low-temperature below 573 K. Therefore, changes in electrical resistivity during tempering directly reflected the decrease in Csol, enabling accurate evaluation when the contribution of carbide precipitation was removed using the spherical dilute-dispersion model. In contrast, high-temperature tempering at 873 K induced pronounced Mn partitioning, and even slight uncertainties in the measured Mn concentration in ferrite led to errors of several hundred ppm in the estimated Csol. Although errors associated with volume fraction and electrical resistivity of carbides also affected the evaluation, their impact was much smaller than that of Mn partitioning. Consequently, except for the high-temperature-tempered Fe–2Mn–0.5Si–C alloy, the final accuracy of Csol measurement can be maintained within several tens of ppm when appropriate corrections are applied.
- Open Access
- 15 December 2024
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 64 (14) , 2042-2050
Ductility Loss of a Metastable Austenitic Stainless Steel and Its TIG Weldment Due to Hydrogen Embrittlement at Low Temperatures Considering the Effect of Pre-strain at 4 K
The amount of martensite in austenitic stainless steels produced during plastic deformation at low temperatures is related to the reduction in hydrogen embrittlement resistance. A pre-strain at 4 K was employed in this work to produce strain-induced martensite (SIM) in the microstructure of SUS316L and its weldment to verify the changes in hydrogen embrittlement susceptibility through slow strain tensile (SSRT) tests in a high-pressure hydrogen environment. As the base metal specimens, the weld metal specimens, manufactured by gas tungsten arc welding (GTAW or TIG) were pre-strained at different levels (5%, 10%, and 15%) for comparison with the non-pre-strained condition. Analysis of the most degraded samples tested from -150 °C to 0 °C is conducted through fracture surface observations, lateral crack length measurement, and crack densities. It was possible to indicate that the pre-strain effect induced earlier crack nucleation in comparison to the situation observed in the non-pre-strained material. Moreover, the pre-existing martensite produced by the pre-strain at 4 K is responsible for earlier crack nucleation, leading to a loss in the hydrogen embrittlement resistance for the SSRT pre-strained base metal specimens.
- 15 December 2024
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 64 (14) , 2042-2050
Open AccessDuctility Loss of a Metastable Austenitic Stainless Steel and Its TIG Weldment Due to Hydrogen Embrittlement at Low Temperatures Considering the Effect of Pre-strain at 4 K
The amount of martensite in austenitic stainless steels produced during plastic deformation at low temperatures is related to the reduction in hydrogen embrittlement resistance. A pre-strain at 4 K was employed in this work to produce strain-induced martensite (SIM) in the microstructure of SUS316L and its weldment to verify the changes in hydrogen embrittlement susceptibility through slow strain tensile (SSRT) tests in a high-pressure hydrogen environment. As the base metal specimens, the weld metal specimens, manufactured by gas tungsten arc welding (GTAW or TIG) were pre-strained at different levels (5%, 10%, and 15%) for comparison with the non-pre-strained condition. Analysis of the most degraded samples tested from -150 °C to 0 °C is conducted through fracture surface observations, lateral crack length measurement, and crack densities. It was possible to indicate that the pre-strain effect induced earlier crack nucleation in comparison to the situation observed in the non-pre-strained material. Moreover, the pre-existing martensite produced by the pre-strain at 4 K is responsible for earlier crack nucleation, leading to a loss in the hydrogen embrittlement resistance for the SSRT pre-strained base metal specimens.
- 20 August 2024
- Published by Elsevier in Computational Materials Science
- Vol. 245
First-Principles study of hydrogen solubility and embrittlement of Cr23C6 in nickel-based alloys
- 20 August 2024
- Published by Elsevier in Computational Materials Science
- Vol. 245
First-Principles study of hydrogen solubility and embrittlement of Cr23C6 in nickel-based alloys
- Open Access
- 1 June 2024
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 110 (8) , 621-631
Effects of Retained Austenite upon Softening during Low-temperature Tempering in Martensitic Carbon Steels
The effects of retained austenite upon softening during low-temperature tempering at 373 K were investigated using martensitic carbon steels with and without retained austenite. To increase the amount of retained austenite, 10 mass% Ni was added to the base carbon steel (Fe-0.3C alloy). During tempering, the hardness decreased more rapidly in the Ni-added steel containing 6 vol.% retained austenite than in the base steel without retained austenite. Analyses of the microstructure and the carbon content in the solid solution (i.e., the solute carbon concentration) revealed that the retained austenite tended to suppress carbide precipitation and significantly reduced the solute carbon concentration in the martensitic matrix. We demonstrated that retained austenite acts as an effective absorption site for solute carbon in the martensitic matrix; however, the partitioned carbon is unevenly localized near the martensite/austenite interface, owing to the poor diffusivity at 373 K.
- 1 June 2024
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 110 (8) , 621-631
Open AccessEffects of Retained Austenite upon Softening during Low-temperature Tempering in Martensitic Carbon Steels
The effects of retained austenite upon softening during low-temperature tempering at 373 K were investigated using martensitic carbon steels with and without retained austenite. To increase the amount of retained austenite, 10 mass% Ni was added to the base carbon steel (Fe-0.3C alloy). During tempering, the hardness decreased more rapidly in the Ni-added steel containing 6 vol.% retained austenite than in the base steel without retained austenite. Analyses of the microstructure and the carbon content in the solid solution (i.e., the solute carbon concentration) revealed that the retained austenite tended to suppress carbide precipitation and significantly reduced the solute carbon concentration in the martensitic matrix. We demonstrated that retained austenite acts as an effective absorption site for solute carbon in the martensitic matrix; however, the partitioned carbon is unevenly localized near the martensite/austenite interface, owing to the poor diffusivity at 373 K.
- Open Access
- 30 January 2024
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 64 (2) , 449-458
Effects of Retained Austenite upon Softening during Low-temperature Tempering in Martensitic Carbon Steels
The effects of retained austenite upon softening during low-temperature tempering at 373 K were investigated using martensitic carbon steels with and without retained austenite. To increase the amount of retained austenite, 10 mass% Ni was added to the base carbon steel (Fe-0.3C alloy). During tempering, the hardness decreased more rapidly in the Ni-added steel containing 6 vol.% retained austenite than in the base steel without retained austenite. Analyses of the microstructure and the carbon content in the solid solution (i.e., the solute carbon concentration) revealed that the retained austenite tended to suppress carbide precipitation and significantly reduced the solute carbon concentration in the martensitic matrix. We demonstrated that retained austenite acts as an effective absorption site for solute carbon in the martensitic matrix; however, the partitioned carbon is unevenly localized near the martensite/austenite interface, owing to the poor diffusivity at 373 K.
- 30 January 2024
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 64 (2) , 449-458
Open AccessEffects of Retained Austenite upon Softening during Low-temperature Tempering in Martensitic Carbon Steels
The effects of retained austenite upon softening during low-temperature tempering at 373 K were investigated using martensitic carbon steels with and without retained austenite. To increase the amount of retained austenite, 10 mass% Ni was added to the base carbon steel (Fe-0.3C alloy). During tempering, the hardness decreased more rapidly in the Ni-added steel containing 6 vol.% retained austenite than in the base steel without retained austenite. Analyses of the microstructure and the carbon content in the solid solution (i.e., the solute carbon concentration) revealed that the retained austenite tended to suppress carbide precipitation and significantly reduced the solute carbon concentration in the martensitic matrix. We demonstrated that retained austenite acts as an effective absorption site for solute carbon in the martensitic matrix; however, the partitioned carbon is unevenly localized near the martensite/austenite interface, owing to the poor diffusivity at 373 K.