Stephanie Nolen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephanie Nolen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ji Yi
Johns Hopkins University
4 shared publications Jingyu Wang
Department of Ophthalmology, School of Medicine, Johns Hopkins University, Baltimore, MD 21231
3 shared publications- Zhongqiang Li
Department of Ophthalmology, School of Medicine, Johns Hopkins University, Baltimore MD, 21231
2 shared publications Amir Kashani
Department of Ophthalmology, Johns Hopkins University, Baltimore, USA
1 shared publication- Jingyu Wang
Johns Hopkins University, School of Medicine, Department of Ophthalmology, Baltimore, Maryland, United States
1 shared publication Mirna El Khatib
Department of Biochemistry and Biophysics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 1-16
Multimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
SignificanceOxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen.AimWe aim to develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO2) and structural volumes in rodents.ApproachC57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 μs pixel dwell time), and a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection.ResultsVIS-OCT images revealed detailed anatomy and Doppler shifts, and PLIM-SLO provided capillary pO2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured, and pO2 was empirically adjusted for the combined excitation.ConclusionDetailed anatomical structures and capillary pO2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 1-16
Open AccessMultimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
SignificanceOxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen.AimWe aim to develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO2) and structural volumes in rodents.ApproachC57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 μs pixel dwell time), and a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection.ResultsVIS-OCT images revealed detailed anatomy and Doppler shifts, and PLIM-SLO provided capillary pO2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured, and pO2 was empirically adjusted for the combined excitation.ConclusionDetailed anatomical structures and capillary pO2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- Open Access
Multimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
Significance: Oxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen. Aim: To develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO 2 ) and structural volumes in rodents. Approach: C57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 µs pixel dwell time), while a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO 2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection. Results: VIS-OCT images revealed detailed anatomy and Doppler shifts, while PLIM-SLO provided capillary pO 2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO 2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured and pO 2 was empirically adjusted for the combined excitation. Conclusions: Detailed anatomical structures and capillary pO 2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
Open AccessMultimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
Significance: Oxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen. Aim: To develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO 2 ) and structural volumes in rodents. Approach: C57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 µs pixel dwell time), while a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO 2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection. Results: VIS-OCT images revealed detailed anatomy and Doppler shifts, while PLIM-SLO provided capillary pO 2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO 2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured and pO 2 was empirically adjusted for the combined excitation. Conclusions: Detailed anatomical structures and capillary pO 2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- 3 February 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (4) , 1061-1064
Depth-gated Fourier transform to accelerate spectral recovery in visible light optical coherence tomography retinal oximetry
Visible light optical coherence tomography (VIS-OCT) provides retinal oximetry at micro-level vessels by performing spatiospectral analysis. Typical methodology involves the short-time Fourier transform (STFT), which requires computationally intensive repetitive transforms. Here we report a depth-gated Fourier transform (DGFT) method to reduce the number of transforms (and time) for spectral extraction by windowing the depth domain. The number of transforms was decreased from 13 to 3 by DGFT, nearly 6× faster in computation time than STFT. We validated DGFT for retinal oximetry in a human eye. Oxygen saturation (sO2) values matched well between STFT and DGFT (percent difference of 0.63% ± 1.10%), while the DGFT extracted spectra significantly faster than the STFT (0.15 ± 0.11 s vs 0.89 ± 0.48 s). The reported method shows potential for real-time oximetry calculation in the future.
- 3 February 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (4) , 1061-1064
Depth-gated Fourier transform to accelerate spectral recovery in visible light optical coherence tomography retinal oximetry
Visible light optical coherence tomography (VIS-OCT) provides retinal oximetry at micro-level vessels by performing spatiospectral analysis. Typical methodology involves the short-time Fourier transform (STFT), which requires computationally intensive repetitive transforms. Here we report a depth-gated Fourier transform (DGFT) method to reduce the number of transforms (and time) for spectral extraction by windowing the depth domain. The number of transforms was decreased from 13 to 3 by DGFT, nearly 6× faster in computation time than STFT. We validated DGFT for retinal oximetry in a human eye. Oxygen saturation (sO2) values matched well between STFT and DGFT (percent difference of 0.63% ± 1.10%), while the DGFT extracted spectra significantly faster than the STFT (0.15 ± 0.11 s vs 0.89 ± 0.48 s). The reported method shows potential for real-time oximetry calculation in the future.
- Open Access
- 31 January 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-13
A dual-channel visible light optical coherence tomography system enables wide-field, full-range, and shot-noise limited human retinal imaging
Visible light optical coherence tomography (VIS-OCT) is an emerging ophthalmic imaging method featuring ultrahigh depth resolution, retinal microvascular oximetry, and distinct scattering contrast in the visible spectral range. The clinical utility of VIS-OCT is hampered by the fundamental trade-off between the imaging depth range and axial resolution, which are determined by the spectral resolution and bandwidth, respectively. To address this trade-off, here we developed a dual-channel VIS-OCT system with three major advancements including the first linear-in-K VIS-OCT spectrometer to decrease the roll-off, reference pathlength modulation to expand the imaging depth range, and per-A-line noise cancellation to remove excess noise, Due to these unique designs, this system achieves 7.2 dB roll-off over the full 1.74 mm depth range (water) with shot-noise limited performance. The system uniquely enables >60° wide-field imaging which would allow simultaneous imaging of the peripheral retina and optic nerve head, as well as ultrahigh 1.3 µm depth resolution (water). Benefiting from the additional near-infrared (NIR) channel of the dual-channel design, this system is compatible with Doppler OCT and OCT angiography (OCTA). The comprehensive structure-function measurement enabled by this dual-channel VIS-OCT system is an advance towards adoption of VIS-OCT in clinical applications.
- 31 January 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-13
Open AccessA dual-channel visible light optical coherence tomography system enables wide-field, full-range, and shot-noise limited human retinal imaging
Visible light optical coherence tomography (VIS-OCT) is an emerging ophthalmic imaging method featuring ultrahigh depth resolution, retinal microvascular oximetry, and distinct scattering contrast in the visible spectral range. The clinical utility of VIS-OCT is hampered by the fundamental trade-off between the imaging depth range and axial resolution, which are determined by the spectral resolution and bandwidth, respectively. To address this trade-off, here we developed a dual-channel VIS-OCT system with three major advancements including the first linear-in-K VIS-OCT spectrometer to decrease the roll-off, reference pathlength modulation to expand the imaging depth range, and per-A-line noise cancellation to remove excess noise, Due to these unique designs, this system achieves 7.2 dB roll-off over the full 1.74 mm depth range (water) with shot-noise limited performance. The system uniquely enables >60° wide-field imaging which would allow simultaneous imaging of the peripheral retina and optic nerve head, as well as ultrahigh 1.3 µm depth resolution (water). Benefiting from the additional near-infrared (NIR) channel of the dual-channel design, this system is compatible with Doppler OCT and OCT angiography (OCTA). The comprehensive structure-function measurement enabled by this dual-channel VIS-OCT system is an advance towards adoption of VIS-OCT in clinical applications.