J. M. Gordon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. M. Gordon has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Bethany L. Goldblum
University of California, Berkeley
6 shared publications - Thibault A. Laplace
University of California, Berkeley
6 shared publications - Christopher A. Brand
University of California, Berkeley
3 shared publications - Darren L. Bleuel
Lawrence Livermore National Laboratory
3 shared publications - Joshua A. Brown
University of California, Berkeley
3 shared publications - Tyler Scott Nagel
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications
Latest Publications
- Open Access
- 3 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering
The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via χ 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98 % -enriched Fe 56 target, GENESIS was used to perform a simultaneous measurement of Fe 56 γ -ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential γ -ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete γ -ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved ( n , 2 n ) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced γ -ray production data while directly probing reaction model physics.
- 3 April 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (4)
Open AccessForward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering
The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via χ 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98 % -enriched Fe 56 target, GENESIS was used to perform a simultaneous measurement of Fe 56 γ -ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential γ -ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete γ -ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved ( n , 2 n ) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced γ -ray production data while directly probing reaction model physics.
- Open Access
- 18 April 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (4)
( ) partial -ray cross section measured using the GENESIS arrayImproved neutron inelastic scattering cross sections have repeatedly been identified as a top priority nuclear data need, important for basic science and a range of applications in nuclear energy, stockpile stewardship, and proliferation detection. For the C 12 ( n , n ′ γ ) reaction in particular, recent measurements have unveiled some structural discrepancies, demonstrating incongruities among themselves and in relation to the ENDF/B-VIII.0 nuclear data evaluation. To help resolve these disagreements, a measurement was performed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory using a broad-spectrum neutron beam and a 99.8% pure natural carbon target. The Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was employed to measure energy-differential γ -ray emission spectra as a function of incident neutron energy in the energy range of 5.5 to 16.7 MeV. The C 12 partial γ -ray cross sections were extracted at 63 ∘ , 122 . 5 ∘ , and 150 ∘ with respect to the incoming neutron beam and integrated using angular distribution data available in the literature. The data show agreement with a recent literature measurement and evaluation from 11 to 15 MeV, but indicate a larger cross section for incident neutron energies between 5.5 and 8.5 MeV. The measured relative angular distributions are also reported and were found to agree with evaluation.
- 18 April 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (4)
Open Access( ) partial -ray cross section measured using the GENESIS arrayImproved neutron inelastic scattering cross sections have repeatedly been identified as a top priority nuclear data need, important for basic science and a range of applications in nuclear energy, stockpile stewardship, and proliferation detection. For the C 12 ( n , n ′ γ ) reaction in particular, recent measurements have unveiled some structural discrepancies, demonstrating incongruities among themselves and in relation to the ENDF/B-VIII.0 nuclear data evaluation. To help resolve these disagreements, a measurement was performed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory using a broad-spectrum neutron beam and a 99.8% pure natural carbon target. The Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was employed to measure energy-differential γ -ray emission spectra as a function of incident neutron energy in the energy range of 5.5 to 16.7 MeV. The C 12 partial γ -ray cross sections were extracted at 63 ∘ , 122 . 5 ∘ , and 150 ∘ with respect to the incoming neutron beam and integrated using angular distribution data available in the literature. The data show agreement with a recent literature measurement and evaluation from 11 to 15 MeV, but indicate a larger cross section for incident neutron energies between 5.5 and 8.5 MeV. The measured relative angular distributions are also reported and were found to agree with evaluation.
- 12 September 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (3)
Measurement of the energy-differential cross section via the ratio with- 12 September 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 110 (3)
Measurement of the energy-differential cross section via the ratio with- Open Access
- 10 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Proton discrimination in CLYC for fast neutron spectroscopy
- 10 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessProton discrimination in CLYC for fast neutron spectroscopy
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I135
Characterization of photodetector temporal response for neutron time-of-flight (nToF) diagnostics at the National Ignition Facility
The temporal response of a microchannel plate photomultiplier tube used in the suite of neutron time of flight (nToF) diagnostics at the National Ignition Facility has been characterized to reduce uncertainty in, and understanding of, shot parameters obtained from nTOF data. A short pulse laser, neutral density glass filters, and electrical attenuators were used to gather statistically significant samples of photodetector impulse response functions (IRF) in rapid succession. Individual components have been absolutely calibrated to minimize systematic uncertainties. The zeroth (collected charge), first (transit time), and second central moments (transit time spread) of the IRF were calculated as either the bias voltage or the amount of light incident on the detector was varied. Timing reference was provided by a monitor photodiode viewing a pickoff of the incident laser pulse. The primary sources of uncertainty are jitter in the monitor photodiode and the statistical variation across our measurement period. The spreads in the first moment, with respect to the timing photodiode, and the square root of the second central moment were found to be less than 50 ps and 150 ps, respectively.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I135
Characterization of photodetector temporal response for neutron time-of-flight (nToF) diagnostics at the National Ignition Facility
The temporal response of a microchannel plate photomultiplier tube used in the suite of neutron time of flight (nToF) diagnostics at the National Ignition Facility has been characterized to reduce uncertainty in, and understanding of, shot parameters obtained from nTOF data. A short pulse laser, neutral density glass filters, and electrical attenuators were used to gather statistically significant samples of photodetector impulse response functions (IRF) in rapid succession. Individual components have been absolutely calibrated to minimize systematic uncertainties. The zeroth (collected charge), first (transit time), and second central moments (transit time spread) of the IRF were calculated as either the bias voltage or the amount of light incident on the detector was varied. Timing reference was provided by a monitor photodiode viewing a pickoff of the incident laser pulse. The primary sources of uncertainty are jitter in the monitor photodiode and the statistical variation across our measurement period. The spreads in the first moment, with respect to the timing photodiode, and the square root of the second central moment were found to be less than 50 ps and 150 ps, respectively.