Emmanuella A. Tagoe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emmanuella A. Tagoe has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Zachary F. Lerner
Mechanical Engineering Department, Northern Arizona University, Flagstaff, AZ, USA
4 shared publications - Collin D. Bowersock
Human Performance and Nutrition Research Institute, Oklahoma State University, Stillwater, OK 74078, USA; Virginia Health Sciences at Old Dominion University, 5115 Hampton Blvd, Norfolk, VA 23529, USA
3 shared publications Karl Harshe
Department of Mechanical Engineering, Northern Arizona University, USA
2 shared publications- Jack R. Williams
Department of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ, USA
1 shared publication - Samuel Hopkins
Mechanical Engineering Department, Northern Arizona University, Flagstaff, AZ, USA
1 shared publication - Shanpu Fang
Department of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ, USA
1 shared publication
Latest Publications
- 14 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-15
Differential and Adjustable Stiffness Leaf Spring Ankle Foot Orthoses Enhance Gait Propulsion and Task Versatility in Cerebral Palsy
Purpose This study explored the effectiveness of a novel differential and adjustable stiffness leaf spring AFO (DAS-AFO) during standing, walking, and sit-to-stand tasks among individuals with cerebral palsy. Methods Eleven individuals with cerebral palsy, ages 12–41, completed treadmill walking trials with the DAS-AFO, a solid (i.e., rigid) AFO, and without an assistive device (shod). We quantified metabolic cost, muscle activity of the soleus and vastus lateralis, and lower body kinetics and kinematics. Participants also performed overground walking, sit-to-stand, and stable standing tasks while wearing the DAS-AFO and reported their preferred stiffness setting for each task. Additionally, we quantified center of pressure during the stable standing task. Results Walking with the DAS-AFO resulted in an average 24% increase in ankle push-off power when compared to the solid AFO (p = .003). Both AFO conditions resulted in an average 16% reduction in soleus activity compared to shod (p < .040); only the DAS-AFO reduced vastus lateralis activity compared to shod (13% average reduction, p = .015). Over half of the participants preferred a different AFO stiffness for at least one of the tasks of daily living. No stiffness setting was universally preferred for a single task. During the stable standing task, the high stiffness setting increased average anterior–posterior center of pressure excursion (p = .022) and velocity (p = .001) compared to shod. Conclusion Our findings highlight potential benefits of the DAS-AFO design over solid AFOs, including improved ankle joint motions and push-off power during walking. Customizability of the DAS-AFO positively influenced participant preference and task performance.
- 14 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-15
Differential and Adjustable Stiffness Leaf Spring Ankle Foot Orthoses Enhance Gait Propulsion and Task Versatility in Cerebral Palsy
Purpose This study explored the effectiveness of a novel differential and adjustable stiffness leaf spring AFO (DAS-AFO) during standing, walking, and sit-to-stand tasks among individuals with cerebral palsy. Methods Eleven individuals with cerebral palsy, ages 12–41, completed treadmill walking trials with the DAS-AFO, a solid (i.e., rigid) AFO, and without an assistive device (shod). We quantified metabolic cost, muscle activity of the soleus and vastus lateralis, and lower body kinetics and kinematics. Participants also performed overground walking, sit-to-stand, and stable standing tasks while wearing the DAS-AFO and reported their preferred stiffness setting for each task. Additionally, we quantified center of pressure during the stable standing task. Results Walking with the DAS-AFO resulted in an average 24% increase in ankle push-off power when compared to the solid AFO (p = .003). Both AFO conditions resulted in an average 16% reduction in soleus activity compared to shod (p < .040); only the DAS-AFO reduced vastus lateralis activity compared to shod (13% average reduction, p = .015). Over half of the participants preferred a different AFO stiffness for at least one of the tasks of daily living. No stiffness setting was universally preferred for a single task. During the stable standing task, the high stiffness setting increased average anterior–posterior center of pressure excursion (p = .022) and velocity (p = .001) compared to shod. Conclusion Our findings highlight potential benefits of the DAS-AFO design over solid AFOs, including improved ankle joint motions and push-off power during walking. Customizability of the DAS-AFO positively influenced participant preference and task performance.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2120-2129
Design and Validation of a Wearable Ankle Push-Off Device in Cerebral Palsy: Is Spring Resistance as Effective as Motorized Resistance?
Objective: Powered ankle exoskeletons with biofeedback systems have proven effective at improving ankle plantar flexor muscle recruitment and push-off power in individuals with cerebral palsy (CP). However, their clinical translation and feasibility for at-home training remain limited. This study sought to design an unpowered wearable ankle device with spring resistance combined with a gamified ankle power biofeedback system. Our primary goal was to validate the device's ability to increase plantar flexor muscle recruitment and push-off power relative to baseline, and ensure that these improvements were comparable to those achieved with motorized resistance. Methods: Seven ambulatory individuals with CP completed walking sessions with (1) a powered ankle exoskeleton with motorized resistance, (2) our novel ankle device with spring resistance, and (3) shoes only (baseline); Both devices utilized the same biofeedback system. Results: Relative to baseline, both the motorized and spring resistance increased peak (48%, p < 0.05) and mean (43–45%, p < 0.05) soleus activation and mean (37–39%, p < 0.05) medial gastrocnemius activation. No differences in muscle recruitment between spring and motorized devices were observed. Walking with spring resistance increased average ankle push-off positive power by 22% (p = 0.003) compared to motorized resistance and by 23% (p = 0.013) compared to baseline. Conclusion: An ankle device providing targeted spring resistance with ankle power biofeedback can effectively improve push-off muscle recruitment and power in individuals with CP. Significance: This supports future research studying outcomes following training with spring-based ankle resistance devices that lower barriers for clinical translation.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2120-2129
Design and Validation of a Wearable Ankle Push-Off Device in Cerebral Palsy: Is Spring Resistance as Effective as Motorized Resistance?
Objective: Powered ankle exoskeletons with biofeedback systems have proven effective at improving ankle plantar flexor muscle recruitment and push-off power in individuals with cerebral palsy (CP). However, their clinical translation and feasibility for at-home training remain limited. This study sought to design an unpowered wearable ankle device with spring resistance combined with a gamified ankle power biofeedback system. Our primary goal was to validate the device's ability to increase plantar flexor muscle recruitment and push-off power relative to baseline, and ensure that these improvements were comparable to those achieved with motorized resistance. Methods: Seven ambulatory individuals with CP completed walking sessions with (1) a powered ankle exoskeleton with motorized resistance, (2) our novel ankle device with spring resistance, and (3) shoes only (baseline); Both devices utilized the same biofeedback system. Results: Relative to baseline, both the motorized and spring resistance increased peak (48%, p < 0.05) and mean (43–45%, p < 0.05) soleus activation and mean (37–39%, p < 0.05) medial gastrocnemius activation. No differences in muscle recruitment between spring and motorized devices were observed. Walking with spring resistance increased average ankle push-off positive power by 22% (p = 0.003) compared to motorized resistance and by 23% (p = 0.013) compared to baseline. Conclusion: An ankle device providing targeted spring resistance with ankle power biofeedback can effectively improve push-off muscle recruitment and power in individuals with CP. Significance: This supports future research studying outcomes following training with spring-based ankle resistance devices that lower barriers for clinical translation.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 10511-10518
Priming Robotic Plantarflexor Resistance With Assistance to Improve Ankle Power During Exoskeleton Gait Training
Robotic exoskeletons are increasingly being used for gait rehabilitation in individuals with neuromuscular disorders, such as cerebral palsy (CP). A primary rehabilitation goal for those with CP is to improve ankle push-off power, which is crucial for enhancing gait function. Previous research suggests that interleaving assistance and resistance within the same training session may improve certain aspects of gait, such as joint trajectories and torque profiles. This feasibility study sought to investigate the efficacy of priming the plantar flexor muscles with ankle exoskeleton plantar flexor assistance to facilitate increased ankle push-off power during subsequent resisted gait training bouts in individuals with CP. Specifically, we hypothesized that providing plantar-flexor assistance immediately prior to walking with resistance would increase peak biological ankle power and muscle activity compared to walking with resistance alone. We found that peak biological ankle power increased by 25% (p = 0.021) during assistance-primed resisted walking compared to the baseline resisted walking trail. While ankle angular velocity also increased alongside power, there was no significant difference in plantar flexor muscle activity, suggesting more efficient recruitment. These results contribute to our overarching goal of optimizing robotic exoskeleton interventions, potentially leading to the future design of more effective gait rehabilitation strategies
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (11) , 10511-10518
Priming Robotic Plantarflexor Resistance With Assistance to Improve Ankle Power During Exoskeleton Gait Training
Robotic exoskeletons are increasingly being used for gait rehabilitation in individuals with neuromuscular disorders, such as cerebral palsy (CP). A primary rehabilitation goal for those with CP is to improve ankle push-off power, which is crucial for enhancing gait function. Previous research suggests that interleaving assistance and resistance within the same training session may improve certain aspects of gait, such as joint trajectories and torque profiles. This feasibility study sought to investigate the efficacy of priming the plantar flexor muscles with ankle exoskeleton plantar flexor assistance to facilitate increased ankle push-off power during subsequent resisted gait training bouts in individuals with CP. Specifically, we hypothesized that providing plantar-flexor assistance immediately prior to walking with resistance would increase peak biological ankle power and muscle activity compared to walking with resistance alone. We found that peak biological ankle power increased by 25% (p = 0.021) during assistance-primed resisted walking compared to the baseline resisted walking trail. While ankle angular velocity also increased alongside power, there was no significant difference in plantar flexor muscle activity, suggesting more efficient recruitment. These results contribute to our overarching goal of optimizing robotic exoskeleton interventions, potentially leading to the future design of more effective gait rehabilitation strategies
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 202-212
Walking on Real-World Terrain With an Ankle Exoskeleton in Cerebral Palsy
Despite medical treatment focused on addressing walking disability, many millions of people with neurological conditions, like cerebral palsy (CP), struggle to maintain independent mobility. Lower limb exoskeletons and exosuits may hold potential for augmenting walking ability. However, it remains unknown whether these wearable robots are safe and beneficial for use outside of highly controlled laboratory environments, the demonstration of which is necessary for clinical translation. Here, we show that a lightweight, portable, ankle exoskeleton with an adaptable one-size-works-for-all assistance controller can improve energy efficiency and walking speed for individuals with CP spanning a wide spectrum of lower limb impairment in a multi-terrain real-world environment. Tested on an outdoor walking route with level, sloped, and stair terrain, robotic assistance resulted in a 15–18% (p ${=}$ 0.013–0.026) reduction in estimated energy cost and a 7–8% (p ${=}$ 0.001–0.004) increase in average walking speed across “shorter” 6-minute and “longer” 20-minute walking durations relative to unassisted walking. This study provides evidence that wearable robots may soon improve mobility in neighborhood, school, and community settings for individuals with CP.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 202-212
Walking on Real-World Terrain With an Ankle Exoskeleton in Cerebral Palsy
Despite medical treatment focused on addressing walking disability, many millions of people with neurological conditions, like cerebral palsy (CP), struggle to maintain independent mobility. Lower limb exoskeletons and exosuits may hold potential for augmenting walking ability. However, it remains unknown whether these wearable robots are safe and beneficial for use outside of highly controlled laboratory environments, the demonstration of which is necessary for clinical translation. Here, we show that a lightweight, portable, ankle exoskeleton with an adaptable one-size-works-for-all assistance controller can improve energy efficiency and walking speed for individuals with CP spanning a wide spectrum of lower limb impairment in a multi-terrain real-world environment. Tested on an outdoor walking route with level, sloped, and stair terrain, robotic assistance resulted in a 15–18% (p ${=}$ 0.013–0.026) reduction in estimated energy cost and a 7–8% (p ${=}$ 0.001–0.004) increase in average walking speed across “shorter” 6-minute and “longer” 20-minute walking durations relative to unassisted walking. This study provides evidence that wearable robots may soon improve mobility in neighborhood, school, and community settings for individuals with CP.