Kanghong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kanghong Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
B. Chen
Materials for Special Environment Division, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
1 shared publication- Chong Zhang
State Key Laboratory of Advanced Power Transmission Technology (China Electric Power Research Institute Co., Ltd.), Beijing 102209, China
1 shared publication - Fei Li
State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China
1 shared publication - Jinghui Gao
Xi’an Jiaotong University
1 shared publication - Lisheng Zhong
Xi’an Jiaotong University
1 shared publication - Wenpeng Li
State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China
1 shared publication
Latest Publications
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1201-1207
Extra-Low Frequency Dielectric Relaxation in HVDC Cable Insulation Material Caused by Cross-Linking Byproduct
The cross-linking byproducts affecting the conductivity of cross-linked polyethylene (XLPE) determine the electric field distribution and temperature stability of cable insulation, and thus the detection of residual cross-linking byproducts plays an important role on the reliability of High Voltage Direct Current (HVDC) cable system. This paper employs the time-dependent polarization current measurement to investigate the dielectric relaxation in XLPE with different contents of cross-linking byproduct at extra-low frequency (ELF). The results show that two Debye-type dielectric relaxations appear at the frequency range of 10 -4 ~10 -3 Hz (defined as α relaxation) and 10 -3 ~10 -2 Hz (defined as β relaxation) respectively, in which the associated static permittivity and the peak losses are proportional to the byproduct contents for the specimens with different degassing time. Further pulsed electro-acoustic measurement (PEA) shows that β relaxation time coincides with time length for accumulation of hetero-charge near electrodes caused by the ionization of byproducts. And the time-dependency of weight loss for the specimen suggests α relaxation might be responsible for the dissipation of cross-linking byproduct during degassing. Our work may shed light on a promising non-destructive approach to detecting the level of residual cross-linking byproducts through dielectric relaxation measurement at extra-low frequency.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1201-1207
Extra-Low Frequency Dielectric Relaxation in HVDC Cable Insulation Material Caused by Cross-Linking Byproduct
The cross-linking byproducts affecting the conductivity of cross-linked polyethylene (XLPE) determine the electric field distribution and temperature stability of cable insulation, and thus the detection of residual cross-linking byproducts plays an important role on the reliability of High Voltage Direct Current (HVDC) cable system. This paper employs the time-dependent polarization current measurement to investigate the dielectric relaxation in XLPE with different contents of cross-linking byproduct at extra-low frequency (ELF). The results show that two Debye-type dielectric relaxations appear at the frequency range of 10 -4 ~10 -3 Hz (defined as α relaxation) and 10 -3 ~10 -2 Hz (defined as β relaxation) respectively, in which the associated static permittivity and the peak losses are proportional to the byproduct contents for the specimens with different degassing time. Further pulsed electro-acoustic measurement (PEA) shows that β relaxation time coincides with time length for accumulation of hetero-charge near electrodes caused by the ionization of byproducts. And the time-dependency of weight loss for the specimen suggests α relaxation might be responsible for the dissipation of cross-linking byproduct during degassing. Our work may shed light on a promising non-destructive approach to detecting the level of residual cross-linking byproducts through dielectric relaxation measurement at extra-low frequency.
- 1 April 2015
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 31 (4) , 423-426
Kinetics of Al Evaporation from Liquid U–Al Alloys in Vacuum Induction Melting
- 1 April 2015
- Published by Elsevier in Journal of Materials Science & Technology
- Vol. 31 (4) , 423-426
Kinetics of Al Evaporation from Liquid U–Al Alloys in Vacuum Induction Melting