Gilberto Gonzalez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gilberto Gonzalez has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Liangzhong Xiang
Department of Radiological Sciences, University of California 1 , Irvine, California 92697
3 shared publications - Prabodh Kumar Pandey
Department of Radiological Sciences, University of California 1 , Irvine, California 92697
3 shared publications Yong Chen
Department of Radiation Oncology, University of Oklahoma Health Sciences Center 2 , Oklahoma City, Oklahoma 73104
2 shared publications- Andrew Anthony Bettiol
National University of Singapore
1 shared publication - Ce-Belle Chen
Centre for Ion Beam Applications, Department of Physics, National University of Singapore 3 , 2 Science Drive 3, Singapore 117542, Singapore
1 shared publication - Frederick Cheong
Centre for Ion Beam Applications, Department of Physics, National University of Singapore 3 , 2 Science Drive 3, Singapore 117542, Singapore
1 shared publication
Latest Publications
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Shape-optimized model-based reconstruction algorithm for radiacoustic imaging
We present a shape-optimized model-based reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct an approximate dose-region boundary using a parametric level set–based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a much better-constrained one. We validate this methodology through computational studies and experiments using clinical x-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with a 3%–25% improvement in correlation coefficients across different imaging settings, with the more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Shape-optimized model-based reconstruction algorithm for radiacoustic imaging
We present a shape-optimized model-based reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct an approximate dose-region boundary using a parametric level set–based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a much better-constrained one. We validate this methodology through computational studies and experiments using clinical x-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with a 3%–25% improvement in correlation coefficients across different imaging settings, with the more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.
- 17 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (7) , 074102
3D protoacoustic radiography: A proof of principle study
We propose protoacoustic radiography (PAR), an imaging modality combining proton excitation and acoustic detection for three-dimensional (3D) imaging from a single proton projection. PAR avoids the effect of multiple Coulomb scattering in imaging by detecting ultrasound. Proton-induced acoustic waves propagate spherically, enabling 3D imaging from a single projection. Additionally, the distinctive feature of proton beams—concentrating energy deposition primarily at the Bragg peak—allows for precise depth-selectivity through proton energy tuning. We performed PAR using clinical proton machines, and our results demonstrate the capability of PAR to reconstruct targets at various depths (between ∼20 and 23 cm) with an axial resolution of 1.3 mm by fully leveraging the Bragg peak and by tuning the kinetic energy of the proton beam. PAR offers opportunities for precise structural determination with protons both in biomedicine and nondestructive testing.
- 17 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (7) , 074102
3D protoacoustic radiography: A proof of principle study
We propose protoacoustic radiography (PAR), an imaging modality combining proton excitation and acoustic detection for three-dimensional (3D) imaging from a single proton projection. PAR avoids the effect of multiple Coulomb scattering in imaging by detecting ultrasound. Proton-induced acoustic waves propagate spherically, enabling 3D imaging from a single projection. Additionally, the distinctive feature of proton beams—concentrating energy deposition primarily at the Bragg peak—allows for precise depth-selectivity through proton energy tuning. We performed PAR using clinical proton machines, and our results demonstrate the capability of PAR to reconstruct targets at various depths (between ∼20 and 23 cm) with an axial resolution of 1.3 mm by fully leveraging the Bragg peak and by tuning the kinetic energy of the proton beam. PAR offers opportunities for precise structural determination with protons both in biomedicine and nondestructive testing.
- Open Access
- 29 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (5) , 053702
Ionic-resolution protoacoustic microscopy: A feasibility study
Visualizing micro- and nano-scale biological entities requires high-resolution imaging and is conventionally achieved via optical microscopic techniques. Optical diffraction limits their resolution to ∼200 nm. This limit can be overcome by using ions with ∼1 MeV energy. Such ions penetrate through several micrometers in tissues, and their much shorter de Broglie wavelengths indicate that these ion beams can be focused to much shorter scales and hence can potentially facilitate higher resolution as compared to the optical techniques. Proton microscopy with ∼1 MeV protons has been shown to have reasonable inherent contrast between sub-cellular organelles. However, being a transmission-based modality, it is unsuitable for in vivo studies and cannot facilitate three-dimensional imaging from a single raster scan. Here, we propose proton-induced acoustic microscopy (PrAM), a technique based on pulsed proton irradiation and proton-induced acoustic signal collection. This technique is capable of label-free, super-resolution, 3D imaging with a single raster scan. Converting radiation energy into ultrasound enables PrAM with reflection mode detection, making it suitable for in vivo imaging and probing deeper than proton scanning transmission ion microscopy (STIM). Using a proton STIM image of HeLa cells, a coupled Monte Carlo+k-wave simulations-based feasibility study has been performed to demonstrate the capabilities of PrAM. We demonstrate that sub-50 nm lateral (depending upon the beam size and energy) and sub-micron axial resolution (based on acoustic detection bandwidth and proton beam pulse width) can be obtained using the proposed modality. By enabling visualization of biological phenomena at cellular and subcellular levels, this high-resolution microscopic technique enhances understanding of intricate cellular processes.
- 29 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (5) , 053702
Open AccessIonic-resolution protoacoustic microscopy: A feasibility study
Visualizing micro- and nano-scale biological entities requires high-resolution imaging and is conventionally achieved via optical microscopic techniques. Optical diffraction limits their resolution to ∼200 nm. This limit can be overcome by using ions with ∼1 MeV energy. Such ions penetrate through several micrometers in tissues, and their much shorter de Broglie wavelengths indicate that these ion beams can be focused to much shorter scales and hence can potentially facilitate higher resolution as compared to the optical techniques. Proton microscopy with ∼1 MeV protons has been shown to have reasonable inherent contrast between sub-cellular organelles. However, being a transmission-based modality, it is unsuitable for in vivo studies and cannot facilitate three-dimensional imaging from a single raster scan. Here, we propose proton-induced acoustic microscopy (PrAM), a technique based on pulsed proton irradiation and proton-induced acoustic signal collection. This technique is capable of label-free, super-resolution, 3D imaging with a single raster scan. Converting radiation energy into ultrasound enables PrAM with reflection mode detection, making it suitable for in vivo imaging and probing deeper than proton scanning transmission ion microscopy (STIM). Using a proton STIM image of HeLa cells, a coupled Monte Carlo+k-wave simulations-based feasibility study has been performed to demonstrate the capabilities of PrAM. We demonstrate that sub-50 nm lateral (depending upon the beam size and energy) and sub-micron axial resolution (based on acoustic detection bandwidth and proton beam pulse width) can be obtained using the proposed modality. By enabling visualization of biological phenomena at cellular and subcellular levels, this high-resolution microscopic technique enhances understanding of intricate cellular processes.