KHKoto Hirano

Koto Hirano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Koto Hirano has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Hideaki Nozato

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan

    5 shared publications
  • Hironobu Takahashi

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan

    5 shared publications
  • Keisuke Yamada

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan

    5 shared publications
  • Hideaki Nozato

    National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology (AIST) 305-8563 Tsukuba Ibaraki Japan

    4 shared publications
  • Hironobu Takahashi

    National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology (AIST) 305-8563 Tsukuba Ibaraki Japan

    4 shared publications
  • Keisuke Yamada

    National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology (AIST) 305-8563 Tsukuba Ibaraki Japan

    4 shared publications

Latest Publications

  • Sensitivity modulus and phase calibration of infrasound sensors using improved liquid-column-type sound pressure generator

    by Koto Hirano, Keisuke Yamada, Hironobu Takahashi, Hideaki Nozato, Shuichi Sakamoto

    Infrasound measurement has become an important tool to monitor large-scale natural phenomena and detect nuclear tests. To ensure reliable and traceable measurements, the calibration of infrasound sensors is essential, particularly in the sub-hertz range, where several primary calibration methods are now under development. In the calibration, not only sensitivity modulus but also phase is a critical parameter to evaluate. Previously, we developed a liquid-column-type sound pressure generator for the primary acoustic calibration of infrasound sensors. In the current study, we modified the apparatus, signal processing method, and the water-motion correction model to enable more precise calibration, and we explicitly evaluated the phase-related terms to perform phase calibration. Calibrations from 0.01 Hz to 1 Hz were performed for a microphone and a barometer. The evaluated sensitivities exhibited agreement within 0.2 dB for the modulus and within 1.0 ∘ for the phase compared with the results obtained using other calibration methods, confirming the validity of this approach. Due to an improvement in the signal-to-noise ratio of more than 20 dB, the expanded uncertainty for a laboratory standard microphone (Brüel & Kjæ r Type 4160) was reduced from a maximum of 2.6 dB in the previous study to 0.3 dB in this study over a frequency range of 0.01–1 Hz.

  • Comparison calibration system for digital-output infrasound sensors

    by Koto Hirano, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato, Shuichi Sakamoto

    Recent advancements in micro electro-mechanical systems (MEMS) have enabled the application of digital-output MEMS modules in infrasound monitoring. These modules, combining MEMS pressure sensors and microcontrollers, provide timestamped digital pressure data. Compared with conventional analog infrasound sensors, the affordability and compactness of MEMS modules allow the construction of infrasound monitoring networks with a high density of measurement stations. However, dynamic frequency response characteristics of the MEMS modules, including both sensitivity modulus and phase, remain unassessed. In this study, we developed a comparison calibration system for digital-output infrasound sensors, with special attention paid to ensuring phase synchronization between the analog-output of reference standards and the digital-output of MEMS modules. Using a pulse per second signal synchronized with a time frequency standard, we successfully timestamped the reference analog signals, achieving synchronization between reference analog standards and digital-output sensors. Example calibrations were conducted on a digital-output MEMS module consisting of a DPS310 MEMS pressure sensor and an ESP32 microcontroller, in the 0.2–4 Hz range. The sensitivity modulus matched the reference within a few percent, but the phase delayed by approximately 10 ms. We anticipate that the applying corrections based on the results reported herein will enhance the reliability of infrasound measurements with digital-output sensors.


  • Optical sound pressure measurement using Fabry-Pérot cavity for primary acoustic standards

    by Koto Hirano, Wataru Kokuyama, Hajime Inaba, Sho Okubo, Tomofumi Shimoda, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry–Pérot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air's refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.


  • Open Access

    Optical sound pressure measurement using Fabry-Pérot cavity for primary acoustic standards

    by Koto Hirano, Wataru Kokuyama, Hajime Inaba, Sho Okubo, Tomofumi Shimoda, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry-Pérot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air’s refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 dB and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.

  • Open Access

    Optical sound pressure measurement using Fabry-Pérot cavity for primary acoustic standards

    by Koto Hirano, Wataru Kokuyama, Hajime Inaba, Sho Okubo, Tomofumi Shimoda, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry-Pérot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air’s refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 dB and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.

  • Open Access

    Optical sound pressure measurement using Fabry-pérot cavity for primary acoustic standards

    by Koto Hirano, Wataru Kokuyama, Sho Okubo, Hajime Inaba, Tomofumi Shimoda, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a Fabry-pérot optical cavity, a phase-stabilized optical frequency comb, and a custom-made phasemeter. The optical cavity detects changes in the air’s refractive index induced by sound waves as changes in its resonance frequency. A continuous-wave laser frequency is stabilized at the resonance, and the frequency comb detects the changes in the laser frequency. The frequency changes are measured with high sensitivity and accuracy using a phasemeter that we developed. The sound pressures measured by this system agreed with the measurement value obtained using a reference microphone within 5% at sound pressure levels of 78 dB and 84 dB, within a frequency range of 100 Hz to 1 kHz. A systematic deviation of 2.6% was observed, with the optical system yielding higher values than the microphone. To identify the cause of this deviation, we performed vibration displacement measurements of the cavity mirrors and finite element analysis, which revealed that fluctuations in the optical path length due to insufficient fixation of the mirrors were responsible.

  • Open Access

    Comparison calibration system for digital-output infrasound sensors

    by Koto Hirano, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato, Shuichi Sakamoto

    Recent advancements in micro electro-mechanical systems (MEMS) have enabled the application of digital-output MEMS modules in infrasound monitoring. These modules, combining MEMS pressure sensors and microcontrollers, provide timestamped digital pressure data. Compared with conventional analog infrasound sensors, the affordability and compactness of MEMS modules allow the construction of infrasound monitoring networks with a high density of measurement stations. However, dynamic frequency response characteristics of the MEMS modules, including both sensitivity modulus and phase, remain unassessed. In this study, we developed a comparison calibration system for digital-output infrasound sensors, with special attention paid to ensuring phase synchronization between the analog-output of reference standards and the digital-output of MEMS modules. Using a pulse per second signal synchronized with a time frequency standard, we successfully timestamped the reference analog signals, achieving synchronization between reference analog standards and digital-output sensors. Example calibrations were conducted on a digital-output MEMS module consisting of a DPS310 MEMS pressure sensor and an ESP32 microcontroller, in the 0.2 Hz to 4 Hz range. The sensitivity modulus matched the reference within a few percent, but the phase delayed by approximately 10 ms. We anticipate that the appliying corrections based on the results reported herein will enhance the reliability of infrasound measurements with digital-output sensors.

  • Calibration of the microphone sensitivity below 0.5 Hz using the liquid-column-type sound pressure generator

    by Keisuke Yamada, Koto Hirano, Hironobu Takahashi, Hideaki Nozato

    The demand for infrasound monitoring has increased to effectively gather information regarding its source phenomena, such as volcanic explosions, tsunamis, and nuclear explosions. To capture infrasound signals, an array of infrasound sensors, including microphones and micro-barometers, has been deployed internationally and locally. Nevertheless, achieving a precise analysis remains challenging because of inconsistencies among different sensor outputs. To ensure the reliability of the measurements, the calibration of sensors below a few Hz, where traceable calibration has not been verified, is required. This paper presents a specialized calibration system designed for infrasonic frequencies. Inspired by a liquid-column manometer, this system uniquely uses the low-frequency vibration of the liquid-column to generate sound pressure, offering three distinct advantages. First, dissimilar to the existing calibration methods, this method eliminates sound pressure leakage by sealing an open end of a closed cylinder with liquid. In addition, the influence of heat conduction is mitigated by direct measurement of the liquid level fluctuation. Finally, the generated sound pressure can be simply calculated if the water level difference in and outside the cylinder is known. Two types of microphones, Brüel & Kjær (BK) Types 4160 and 4193, were calibrated within a frequency range of 0.01 Hz–2 Hz. The results demonstrated that the pressure sensitivity of BK Type 4160 calibrated by this method agreed with the sensitivity calibrated by the laser pistonphone method within 0.1 dB at 0.5 Hz. Furthermore, at lower frequencies, the frequency response calibrated using the proposed method was consistent with the response evaluated by comparison with a barometer. Similar results were obtained for the free-field sensitivity of BK Type 4193. The study findings confirmed the ability of the proposed system to calibrate different types of microphones.


  • Investigation of sound pressure leakage effect for primary calibration down to 10−2 Hz using a laser pistonphone system

    by Koto Hirano, Hironobu Takahashi, Keisuke Yamada, Hideaki Nozato

    Recently, the demand for sensor calibration in the infrasonic range has increased to obtain accurate information when monitoring infrasound generated by large-scale natural disasters. The laser pistonphone method is a primary calibration method to evaluate infrasound sensors in the low-frequency range. In this method, sound pressure is generated in a fixed sealed volume of air, by a volume change via an attached piston movement. By measuring the piston displacement using laser interferometer, the generated sound pressure can be calculated by multiplying the velocity of volume change by acoustic transfer impedance of a pistonphone. The main concern with this method is that sound pressure leakage from a gap adjacent to piston significantly changes the acoustic transfer impedance at lower frequencies. To apply the laser pistonphone method in the low-frequency range down to 10−2 Hz, it is essential to accurately evaluate and compensate for the leakage effect, i.e. the gap’s acoustic transfer impedance. In this study, we propose a technique for experimentally evaluating the gap impedance. The main idea is to determine the total acoustic transfer impedance by dividing the sound pressure by the volume velocity and then deducing the gap impedance by subtracting the chamber impedance from the obtained total acoustic transfer impedance. A digital pressure sensor was used to precisely measure sound pressure below 100 Hz because pressure sensors are suitable for accurate measurement of pressure fluctuations at low frequencies. We validated the proposed approach by calibrating an analog pressure sensor that outputs an analog voltage proportional to the absolute pressure. As a result, the sensitivity calibrated by the laser pistonphone method at 0.02 Hz agreed with the static sensitivity provided by the manufacturer within 0.02 dB.