Hakjae Lee
Hakjae Lee has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Chul Hee Min
Department of Radiation Convergence Engineering, Yonsei University, Republic of Korea
3 shared publications - Kisung Lee
Department of Bioengineering, Korea University, Seoul, Republic of Korea
3 shared publications Bo-Wi Cheon
1 shared publication- Bo-Wi Cheon
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
1 shared publication Boram Lee
Korea Univ, Dept Biomed Engn, Seoul, South Korea
1 shared publication- Boram Lee
Department of Radiation Oncology, Inha University Hospital, Incheon, Republic of Korea
1 shared publication
Latest Publications
- 18 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
Development of a high energy γ-rays distribution monitoring system for nuclear power plant decommissioning using pinhole gamma camera
- 18 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
Development of a high energy γ-rays distribution monitoring system for nuclear power plant decommissioning using pinhole gamma camera
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , P06030
Prompt-gamma tomographic imaging for range verification in pencil beam-scanning proton therapy
This study aimed to develop a prompt-gamma imaging system to verify the range of proton beams. We designed an optimized collimation system and calculated the proton range using the GATE nuclear-medicine simulation toolkit (v. 9.1). An initial system, which was devised using protons without including specific equipment models, was employed to assess proton beams with energy ranges of 80, 90, 100, 110, and 120 MeV. The gamma-camera system design does not interfere with the nozzle structure of the treatment equipment. It consists of a pinhole collimator and a BGO scintillator and has a 100 × 100-pixel array with a 0.5 mm× 0.5-mm pitch. Next, we constructed an entire system using 12 gamma camera systems for prompt-gamma detection. The pinhole collimator was optimized with respect to the 4.4-MeV prompt-gamma energy, considering the detection efficiency and full width at half maximum. Finally, the prompt-gamma rays at 2.2, 4.4, and 6.1 MeV were comparatively analyzed using an in-house program. Based on the simulation results, the pinhole collimator was optimized to a 1-cm height and 3-mm diameter. The peak of the 4.4-MeV prompt gamma and the reconstructed peak point matched within 1 mm for most simulated energies. These results showed that our newly proposed imaging system is capable of accurately monitoring the proton range using specific prompt-gamma energies.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , P06030
Prompt-gamma tomographic imaging for range verification in pencil beam-scanning proton therapy
This study aimed to develop a prompt-gamma imaging system to verify the range of proton beams. We designed an optimized collimation system and calculated the proton range using the GATE nuclear-medicine simulation toolkit (v. 9.1). An initial system, which was devised using protons without including specific equipment models, was employed to assess proton beams with energy ranges of 80, 90, 100, 110, and 120 MeV. The gamma-camera system design does not interfere with the nozzle structure of the treatment equipment. It consists of a pinhole collimator and a BGO scintillator and has a 100 × 100-pixel array with a 0.5 mm× 0.5-mm pitch. Next, we constructed an entire system using 12 gamma camera systems for prompt-gamma detection. The pinhole collimator was optimized with respect to the 4.4-MeV prompt-gamma energy, considering the detection efficiency and full width at half maximum. Finally, the prompt-gamma rays at 2.2, 4.4, and 6.1 MeV were comparatively analyzed using an in-house program. Based on the simulation results, the pinhole collimator was optimized to a 1-cm height and 3-mm diameter. The peak of the 4.4-MeV prompt gamma and the reconstructed peak point matched within 1 mm for most simulated energies. These results showed that our newly proposed imaging system is capable of accurately monitoring the proton range using specific prompt-gamma energies.
- Open Access
- 24 June 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (11) , 4770-4781
Image reconstruction method of gamma emission tomography based on prior-aware information and machine learning for partial-defect detection of PWR-type spent nuclear fuel
- 24 June 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (11) , 4770-4781
Open AccessImage reconstruction method of gamma emission tomography based on prior-aware information and machine learning for partial-defect detection of PWR-type spent nuclear fuel
- Open Access
- 30 March 2024
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 49 (1) , 29-39
Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage
Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images.Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly.Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA’s device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability.Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.
- 30 March 2024
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 49 (1) , 29-39
Open AccessOptimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage
Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images.Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly.Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA’s device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability.Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.
- 9 February 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 218
Development of a novel radiation monitoring system using a variable lofthole collimator
- 9 February 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 218
Development of a novel radiation monitoring system using a variable lofthole collimator
- Open Access
- 31 January 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (6) , 2412-2420
Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel
- 31 January 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (6) , 2412-2420
Open AccessFeasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3121-3124
3D breast registration for PET-CT and MR based on surface matching
The objective of this study is to develop a 3D breast image registration algorithm for PET-CT and MR system. Proposed algorithm consists of three stages: breast segmentation, surface matching, and image transformation. Contrast-enhanced MR image volume was used as a reference and CT volume was transformed with varying parameters to calculate similarity between two image modalities. At first, the breast regions were cropped separately by the pre-determined regional masks. For the CT image case, region growing based breast segmentation was explored to eliminate the breast dedicated jig which has been developed to hold the shape of breast during PET-CT scan. After the segmentation, each of the points set of breast surface has been extracted. The extracted point sets were used as a feature vector for the surface matching. For the surface matching, we developed modified version of elastic-convolved iterative closest point (ECICP) algorithm to obtain the optimal transformation parameters. Then PET image was transformed with those parameters and overlaid it onto MR image. The results of this study show that the difference between MR and CT image has been considerably reduced and the suspicious lesions on MR and PET images were matched as well.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3121-3124
3D breast registration for PET-CT and MR based on surface matching
The objective of this study is to develop a 3D breast image registration algorithm for PET-CT and MR system. Proposed algorithm consists of three stages: breast segmentation, surface matching, and image transformation. Contrast-enhanced MR image volume was used as a reference and CT volume was transformed with varying parameters to calculate similarity between two image modalities. At first, the breast regions were cropped separately by the pre-determined regional masks. For the CT image case, region growing based breast segmentation was explored to eliminate the breast dedicated jig which has been developed to hold the shape of breast during PET-CT scan. After the segmentation, each of the points set of breast surface has been extracted. The extracted point sets were used as a feature vector for the surface matching. For the surface matching, we developed modified version of elastic-convolved iterative closest point (ECICP) algorithm to obtain the optimal transformation parameters. Then PET image was transformed with those parameters and overlaid it onto MR image. The results of this study show that the difference between MR and CT image has been considerably reduced and the suspicious lesions on MR and PET images were matched as well.