Laura Pierce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laura Pierce has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Sumona Sarkar
Department of Biomedical Engineering, Boston University, 44 Cummington Street, Boston, MA 02215, USA
2 shared publications - Alshae' R. Logan-Jackson
Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, MI 48824, USA
1 shared publication D. Newton
National Institute of Standards and Technology (NIST), Statistical Engineering Division, Boulder, CO, USA
1 shared publicationHidayah Anderson
Division of Cellular & Gene Therapies, CBER, FDA, Silver Spring, MD 20993, USA
1 shared publicationJ. Dootz
National Institute of Standards and Technology (NIST), Biosystems and Biomaterials Division, Gaithersburg, MD, USA
1 shared publication- Joy P. Dunkers
National Institute of Standards and Technology (NIST), Biosystems and Biomaterials Division, Gaithersburg, MD, USA
1 shared publication
Latest Publications
- Open Access
Measurement Quality Metrics to Improve Absolute Microbial Cell Counting
Total and viable microbial cell counts are increasingly important for applications including live biotherapeutic products, food safety, and probiotics. In microbiology, cells are quantified using methods such as colony forming unit (CFU), flow cytometry, and polymerase chain reaction (PCR), but different methods measure different aspects of the cells (measurands), and results may not be directly comparable across methods. In the absence of a ground-truth reference material for cell count, one cannot quantify the accuracy of any cell counting method, which limits method performance assessments and comparisons. Herein, a modified analysis of cell counting methods based on the ISO 20391-2:2019 standard was developed and demonstrated for microbial cell samples diluted over a log-scale range of concentrations. Escherichia coli samples ranging in concentration from approximately 5 × 10 5 cells/mL to 2 × 10 7 cells/mL were quantified using CFU, Coulter principle, fluorescence flow cytometry, and impedance flow cytometry. Quality metrics modified from the ISO standard were calculated for each method and shown to be repeatable across replicate experiments. The quality metrics illustrate large differences in proportionality and variability across methods, with total cell counts in good agreement and viable cell count having more variability. As the ISO standard is meant to guide fit-for-purpose method selection, interpretation of the results and quality metrics can drive method choice and optimization. The framework introduced here will help researchers select fit-for-purpose counting methods for quantification of microbial total and viable cells across a range of applications.
Open AccessMeasurement Quality Metrics to Improve Absolute Microbial Cell Counting
Total and viable microbial cell counts are increasingly important for applications including live biotherapeutic products, food safety, and probiotics. In microbiology, cells are quantified using methods such as colony forming unit (CFU), flow cytometry, and polymerase chain reaction (PCR), but different methods measure different aspects of the cells (measurands), and results may not be directly comparable across methods. In the absence of a ground-truth reference material for cell count, one cannot quantify the accuracy of any cell counting method, which limits method performance assessments and comparisons. Herein, a modified analysis of cell counting methods based on the ISO 20391-2:2019 standard was developed and demonstrated for microbial cell samples diluted over a log-scale range of concentrations. Escherichia coli samples ranging in concentration from approximately 5 × 10 5 cells/mL to 2 × 10 7 cells/mL were quantified using CFU, Coulter principle, fluorescence flow cytometry, and impedance flow cytometry. Quality metrics modified from the ISO standard were calculated for each method and shown to be repeatable across replicate experiments. The quality metrics illustrate large differences in proportionality and variability across methods, with total cell counts in good agreement and viable cell count having more variability. As the ISO standard is meant to guide fit-for-purpose method selection, interpretation of the results and quality metrics can drive method choice and optimization. The framework introduced here will help researchers select fit-for-purpose counting methods for quantification of microbial total and viable cells across a range of applications.
- 22 January 2024
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 19 (1) , 27-45
Experimental and Computational Approach to Establish Fit-for-Purpose Cell Viability Assays
Aim: Cell viability assays are critical for cell-based products. Here, we demonstrate a combined experimental and computational approach to identify fit-for-purpose cell assays that can predict cha... Plain language summary In recent years, there has been a surge in the amount of cellular therapy products which have been engineered to treat patients with severe diseases. These cellular products ... Graphical abstract
- 22 January 2024
- Published by Taylor & Francis in Regenerative Medicine
- Vol. 19 (1) , 27-45
Experimental and Computational Approach to Establish Fit-for-Purpose Cell Viability Assays
Aim: Cell viability assays are critical for cell-based products. Here, we demonstrate a combined experimental and computational approach to identify fit-for-purpose cell assays that can predict cha... Plain language summary In recent years, there has been a surge in the amount of cellular therapy products which have been engineered to treat patients with severe diseases. These cellular products ... Graphical abstract