Anna Selby
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anna Selby has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Callum Presslie
School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, UK
1 shared publication- Catherine Mary Hill
Faculty of Medicine, University of Southampton, Southampton, UK
1 shared publication Elise Buchan
Respiratory and sleep physiology, Royal Hospital for Children, Glasgow, UK
1 shared publicationEmily Senior
Paediatric Sleep and Respiratory Medicine Department, Guy's and St Thomas' Hospitals NHS Trust, London, UK
1 shared publication- Hazel J. Evans
Paediatric Respiratory Medicine, University Hospital Southampton NHS Foundation Trust, Southampton, UK
1 shared publication Ho Ming Yuen
Faculty of Medicine, University of Southampton, Southampton, UK
1 shared publication
Latest Publications
- Open Access
- 4 July 2024
- Published by Springer Nature
Prescription Alerts for Reliever inhalers in Children (PARC) project
- 4 July 2024
- Published by Springer Nature
Open AccessPrescription Alerts for Reliever inhalers in Children (PARC) project
- 22 January 2024
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (4) , 308-313
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in typically developing children: a multicentre study
Background and objective Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is, however, cheaper and more accessible. This study evaluated the ability of NPO indices to predict OSA in typically developing (TD) children. Methods Indices from simultaneous NPO and CRP recordings were compared in TD children (aged 1–16 years) referred to evaluate OSA in three tertiary centres. OSA was defined as an obstructive apnoea–hypopnoea index (OAHI) ≥1 event/hour. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices including ODI3 (3% Oxygen Desaturation Index, ODI4 (4% Oxygen Desaturation Index), delta 12 s index and minimum oxygen saturation. Two-by-two tables were generated to determine the sensitivities and specificities of whole number cut-off values for predicting OAHIs ≥1, 5 and 10 events/hour. Results Recordings from 322 TD children, 197 male (61.2%), median age 4.9 years (range 1.1–15.6), were reviewed. OAHI was ≥1/hour in 144 (44.7%), ≥5/hour in 61 (18.9%) and ≥10/hour in 28 (8.7%) cases. ODI3 and ODI4 had the best diagnostic accuracy. ODI3 ≥7/hour and ODI4 ≥4/hour predicted OSA in TD children with sensitivities/specificities of 57.6%/85.4% and 46.2%/91.6%, respectively. ODI3 ≥8/hour was the best predictor of OAHI ≥5/hour (sensitivity 82.0%, specificity 84.3%). Conclusion Raised ODI3 and ODI4 predict OSA in TD children with high specificity but variable sensitivity. NPO may be an alternative to diagnose moderate-severe OSA if access to CRP is limited. Low sensitivities to detect mild OSA mean that confirmatory CRP is needed if NPO is normal.
- 22 January 2024
- Published by BMJ in Archives of Disease in Childhood
- Vol. 109 (4) , 308-313
Role of overnight oximetry in assessing the severity of obstructive sleep apnoea in typically developing children: a multicentre study
Background and objective Cardiorespiratory polygraphy (CRP) is the predominant technology used to diagnose obstructive sleep apnoea (OSA) in tertiary centres in the UK. Nocturnal pulse oximetry (NPO) is, however, cheaper and more accessible. This study evaluated the ability of NPO indices to predict OSA in typically developing (TD) children. Methods Indices from simultaneous NPO and CRP recordings were compared in TD children (aged 1–16 years) referred to evaluate OSA in three tertiary centres. OSA was defined as an obstructive apnoea–hypopnoea index (OAHI) ≥1 event/hour. Receiver operating characteristic curves assessed the diagnostic accuracy of NPO indices including ODI3 (3% Oxygen Desaturation Index, ODI4 (4% Oxygen Desaturation Index), delta 12 s index and minimum oxygen saturation. Two-by-two tables were generated to determine the sensitivities and specificities of whole number cut-off values for predicting OAHIs ≥1, 5 and 10 events/hour. Results Recordings from 322 TD children, 197 male (61.2%), median age 4.9 years (range 1.1–15.6), were reviewed. OAHI was ≥1/hour in 144 (44.7%), ≥5/hour in 61 (18.9%) and ≥10/hour in 28 (8.7%) cases. ODI3 and ODI4 had the best diagnostic accuracy. ODI3 ≥7/hour and ODI4 ≥4/hour predicted OSA in TD children with sensitivities/specificities of 57.6%/85.4% and 46.2%/91.6%, respectively. ODI3 ≥8/hour was the best predictor of OAHI ≥5/hour (sensitivity 82.0%, specificity 84.3%). Conclusion Raised ODI3 and ODI4 predict OSA in TD children with high specificity but variable sensitivity. NPO may be an alternative to diagnose moderate-severe OSA if access to CRP is limited. Low sensitivities to detect mild OSA mean that confirmatory CRP is needed if NPO is normal.