Amanda Lynggaard Elkjær
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amanda Lynggaard Elkjær has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Elisabeth Bendstrup
Aarhus University Hospital
2 shared publications - Esben Næser
Aarhus University Hospital
2 shared publications - Katja Thorup Aaen
Department of Rheumatology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 59, Aarhus N, 8200, Denmark
2 shared publications - Klaus Søndergaard
Department of Rheumatology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8000 Aarhus C, Denmark
2 shared publications - Gitte Rye Hinrichs
University of Southern Denmark
1 shared publication - Henrik Lynge Hovgaard
Aarhus University Hospital, Aarhus, Denmark
1 shared publication
Latest Publications
- Open Access
- 9 June 2026
- Published by American Physiological Society in American Journal of Physiology-Endocrinology and Metabolism
Liver and Kidney Crosstalk – Liver-derived Bile Acids and Kidney Water Retention
Edema formation and ascites are common features in liver disease. The excessive accumulation of body water is caused by increased kidney water retention; yet the mechanisms linking liver and kidney function remain incompletely understood. This review explores the emerging concept of a liver-kidney axis, with bile acids (BAs) as potential mediators for kidney water handling. In cholestatic liver disease, as seen in liver cirrhosis, impaired hepatic BA flow to the duodenum elevates systemic BA concentrations, which can modulate signaling pathways through the BA receptors Farnesoid X Receptor (FXR, NR1H4) and G-protein-coupled bile acid receptor 1 (TGR5, GPBAR1), thereby increasing kidney Na + and water retention in experimental models. Moreover, BAs can directly activate the sodium channel ENaC in isolated mouse collecting ducts and in mouse distal colon epithelial cells. Thus, BAs can promote sodium and water retention in parallel with the classical sodium- and water-retaining systems, such as the renin-angiotensin-aldosterone system. This effect may potentially contribute to water retention in pregnancy-associated conditions and in proteinuric kidney diseases, where liver function is affected, e.g., by loss of plasma proteins, altering hepatic BA metabolism. In this review, we will describe the synthesis of BAs, their modifications, and kidney BA metabolism in health and disease, and highlight a potential dynamic interplay between liver and kidney function, mediated in part by BAs, with implications for understanding and treating water retention disorders.
- 9 June 2026
- Published by American Physiological Society in American Journal of Physiology-Endocrinology and Metabolism
Open AccessLiver and Kidney Crosstalk – Liver-derived Bile Acids and Kidney Water Retention
Edema formation and ascites are common features in liver disease. The excessive accumulation of body water is caused by increased kidney water retention; yet the mechanisms linking liver and kidney function remain incompletely understood. This review explores the emerging concept of a liver-kidney axis, with bile acids (BAs) as potential mediators for kidney water handling. In cholestatic liver disease, as seen in liver cirrhosis, impaired hepatic BA flow to the duodenum elevates systemic BA concentrations, which can modulate signaling pathways through the BA receptors Farnesoid X Receptor (FXR, NR1H4) and G-protein-coupled bile acid receptor 1 (TGR5, GPBAR1), thereby increasing kidney Na + and water retention in experimental models. Moreover, BAs can directly activate the sodium channel ENaC in isolated mouse collecting ducts and in mouse distal colon epithelial cells. Thus, BAs can promote sodium and water retention in parallel with the classical sodium- and water-retaining systems, such as the renin-angiotensin-aldosterone system. This effect may potentially contribute to water retention in pregnancy-associated conditions and in proteinuric kidney diseases, where liver function is affected, e.g., by loss of plasma proteins, altering hepatic BA metabolism. In this review, we will describe the synthesis of BAs, their modifications, and kidney BA metabolism in health and disease, and highlight a potential dynamic interplay between liver and kidney function, mediated in part by BAs, with implications for understanding and treating water retention disorders.
- Open Access
- 9 June 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 260, 108950
Physiological responses and clinical associations of the one-minute sit-to-stand test and the six-minute walk test in systemic sclerosis
- 9 June 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 260, 108950
Open AccessPhysiological responses and clinical associations of the one-minute sit-to-stand test and the six-minute walk test in systemic sclerosis
- Open Access
- 10 February 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (4) , 611-620
Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud’s phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland–Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was − 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
- 10 February 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (4) , 611-620
Open AccessValidity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud’s phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland–Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was − 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).