Katja Thorup Aaen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katja Thorup Aaen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Elisabeth Bendstrup
Aarhus University Hospital
3 shared publications - Amanda Lynggaard Elkjær
University of Southern Denmark
2 shared publications - Esben Næser
Aarhus University Hospital
2 shared publications - Henrik Lynge Hovgaard
Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Klaus Søndergaard
Department of Rheumatology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8000 Aarhus C, Denmark
2 shared publications - Peter Juhl-Olsen
Department of Anaesthesiology and Intensive Care, Aarhus University Hospital, Aarhus, Denmark
2 shared publications
Latest Publications
- Open Access
- 9 June 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 260, 108950
Physiological responses and clinical associations of the one-minute sit-to-stand test and the six-minute walk test in systemic sclerosis
- 9 June 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 260, 108950
Open AccessPhysiological responses and clinical associations of the one-minute sit-to-stand test and the six-minute walk test in systemic sclerosis
- Open Access
- 10 February 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (4) , 611-620
Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud’s phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland–Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was − 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
- 10 February 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (4) , 611-620
Open AccessValidity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud’s phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland–Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was − 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
- Open Access
- 7 June 2023
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 82 (Suppl 1) , 1623-1624
AB0821 VALIDITY AND RELIABILITY OF MEASUREMENT OF PERIPHERAL OXYGEN SATURATION DURING THE 6-MINUTE WALK TEST IN PATIENTS WITH SYSTEMIC SCLEROSIS
Background The 6-Minute Walk Test (6MWT) is a standardised method routinely used to screen for and monitor interstitiel lunge disease and/or pulmonary arterial hypertension in patients with systemic sclerosis (SSc). Studies shows that esaturations during the 6MWT are associated with severity of pulmonary manifestations in patients with SSc [1]. Digital sensors are commonly used to measure peripheral oxygen saturation (SpO2) during the 6MWT. However, digital-based sensors may have important limitations in patients with SSc due to disease-related microangiopathy, Raynaud’s phenomenon, sclerodactyly and motion artifacts during the 6MWT [2]. Sensors located at more central body positions may therefore be more accurate as these as less prone to Raynaud attacks. Objectives To determine the validity and re-test reliability of peripheral oxygen saturation measured at the finger, forehead, and ear during the 6MWT in patients with SSc. Methods 82 patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later. We used Bland-Altman plots to display the agreement between SpO2 and SaO2, and between the minimal SpO2 (minSpO2) one week apart. The intraclass correlation coefficient (ICC, 95% confidence interval 95% CI]) for repeated measurement of minSpO2 was calculated. Results The mean difference (SpO2 - SaO2, ± standard deviation [SD]) after the 6MWT was –3.3% (±4.82), 0.15% (±1.55), and 1.36% (±1.93) for the finger, forehead, and earlobe, respectively (Table 1). The finger minSpO2 also demonstrated the poorest re-test reliability: The mean difference in minSpO2 (visit2-visit1, ±SD) was 1.28% (±5.3), 0.74% (±4.36) and –1.10% (±2.87),). The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [0.80; 0.94]; ICCforehead = 0.88 [0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 [0.43; 0.80]). Conclusion Peripheral oxygen saturation should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. References [1]Villalba, W. O. et al. Six-minute walk test for the evaluation of pulmonary disease severity in scleroderma patients. Chest 131, 217–222 (2007). [2]Pathania, Y. S. Alternatives for erroneous finger probe pulse oximetry in systemic sclerosis patients during COVID-19 pandemic. Rheumatol. Int. 41, 2243–2244 (2021). Validity and re-test reliability of peripheral oxygen during the 6MWT (n= 82) Acknowledgements: NIL. Disclosure of Interests Amanda Lynggaard Riis: None declared, Esben Naeser Paid instructor for: Boehringer Ingelheim Denmark, Katja Thorup Aaen: None declared, Henrik Hovgaard: None declared, Peter Juhl-Olsen: None declared, Elisabeth Bendstrup Speakers bureau: Hoffman-la-Roche. Boehringer Ingelheim. Glaxo Smith Kleine. Daichii Sankyo, Klaus Soendergaard Speakers bureau: Boehringer Ingelheim, Consultant of: Boehringer Ingelheim, Grant/research support from: Boehringer Ingelheim.
- 7 June 2023
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 82 (Suppl 1) , 1623-1624
Open AccessAB0821 VALIDITY AND RELIABILITY OF MEASUREMENT OF PERIPHERAL OXYGEN SATURATION DURING THE 6-MINUTE WALK TEST IN PATIENTS WITH SYSTEMIC SCLEROSIS
Background The 6-Minute Walk Test (6MWT) is a standardised method routinely used to screen for and monitor interstitiel lunge disease and/or pulmonary arterial hypertension in patients with systemic sclerosis (SSc). Studies shows that esaturations during the 6MWT are associated with severity of pulmonary manifestations in patients with SSc [1]. Digital sensors are commonly used to measure peripheral oxygen saturation (SpO2) during the 6MWT. However, digital-based sensors may have important limitations in patients with SSc due to disease-related microangiopathy, Raynaud’s phenomenon, sclerodactyly and motion artifacts during the 6MWT [2]. Sensors located at more central body positions may therefore be more accurate as these as less prone to Raynaud attacks. Objectives To determine the validity and re-test reliability of peripheral oxygen saturation measured at the finger, forehead, and ear during the 6MWT in patients with SSc. Methods 82 patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later. We used Bland-Altman plots to display the agreement between SpO2 and SaO2, and between the minimal SpO2 (minSpO2) one week apart. The intraclass correlation coefficient (ICC, 95% confidence interval 95% CI]) for repeated measurement of minSpO2 was calculated. Results The mean difference (SpO2 - SaO2, ± standard deviation [SD]) after the 6MWT was –3.3% (±4.82), 0.15% (±1.55), and 1.36% (±1.93) for the finger, forehead, and earlobe, respectively (Table 1). The finger minSpO2 also demonstrated the poorest re-test reliability: The mean difference in minSpO2 (visit2-visit1, ±SD) was 1.28% (±5.3), 0.74% (±4.36) and –1.10% (±2.87),). The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [0.80; 0.94]; ICCforehead = 0.88 [0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 [0.43; 0.80]). Conclusion Peripheral oxygen saturation should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. References [1]Villalba, W. O. et al. Six-minute walk test for the evaluation of pulmonary disease severity in scleroderma patients. Chest 131, 217–222 (2007). [2]Pathania, Y. S. Alternatives for erroneous finger probe pulse oximetry in systemic sclerosis patients during COVID-19 pandemic. Rheumatol. Int. 41, 2243–2244 (2021). Validity and re-test reliability of peripheral oxygen during the 6MWT (n= 82) Acknowledgements: NIL. Disclosure of Interests Amanda Lynggaard Riis: None declared, Esben Naeser Paid instructor for: Boehringer Ingelheim Denmark, Katja Thorup Aaen: None declared, Henrik Hovgaard: None declared, Peter Juhl-Olsen: None declared, Elisabeth Bendstrup Speakers bureau: Hoffman-la-Roche. Boehringer Ingelheim. Glaxo Smith Kleine. Daichii Sankyo, Klaus Soendergaard Speakers bureau: Boehringer Ingelheim, Consultant of: Boehringer Ingelheim, Grant/research support from: Boehringer Ingelheim.