Xipeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xipeng Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Nengling Tai
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, CO 200240 China
5 shared publicationsWentao Huang
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, CO 200240 China
4 shared publications- Xiaodong Zheng
Key Laboratory of Control of Power Transmission and Conversion (Ministry of Education), Shanghai Jiao Tong University, Shanghai, China
3 shared publications Chunju Fan
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, CO 200240 China
2 shared publications- Pan Wu
Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, CO 200240 China
2 shared publications Xiaodong Zheng
Department of Electrical Engineering Shanghai Jiao Tong University Minhang Shanghai People's Republic of China
2 shared publications
Latest Publications
- Open Access
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 91337-91346
A New Theory for Locating Line Fault in Power System: Theoretical Part
This paper proposes a theory for locating line fault based on the basic principle of time reversal. The proof has five steps. Firstly, the theoretical voltage and current at the ends of the line are calculated based on the transmission equation of the line in the additional network after line fault occurred. Secondly, the loss and lossless mirror line are established according to the parameters of the actual line, respectively. Thirdly, the values of the implemented sources at the ends of the mirror line are calculated based on the conjugate complex of the theoretical values of voltage and current in the first step. Fourthly, the RMS value of the fault current is calculated by assuming that fault occurs at every point of the mirror line. Finally, we should identify that there is only one peak value among all the RMS values and it exists at the actual fault location. In this paper, the fault location theory is proved with and without reflected waves by using the transmission equation of a single line. It is further proved in the mixed line that consists of two lines of different parameters considering the reflections.
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 91337-91346
Open AccessA New Theory for Locating Line Fault in Power System: Theoretical Part
This paper proposes a theory for locating line fault based on the basic principle of time reversal. The proof has five steps. Firstly, the theoretical voltage and current at the ends of the line are calculated based on the transmission equation of the line in the additional network after line fault occurred. Secondly, the loss and lossless mirror line are established according to the parameters of the actual line, respectively. Thirdly, the values of the implemented sources at the ends of the mirror line are calculated based on the conjugate complex of the theoretical values of voltage and current in the first step. Fourthly, the RMS value of the fault current is calculated by assuming that fault occurs at every point of the mirror line. Finally, we should identify that there is only one peak value among all the RMS values and it exists at the actual fault location. In this paper, the fault location theory is proved with and without reflected waves by using the transmission equation of a single line. It is further proved in the mixed line that consists of two lines of different parameters considering the reflections.
- Open Access
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 93858-93870
A New Theory for Locating Line Fault in Power System: Simulation Part
Three time-reversal-based fault location methods are derived from the theoretical part of this paper, which are named currents-in-time-domain method, forward-currents-in-frequency-domain method, and forward-currents-in-frequency-domain-with-compensation method, respectively. The first proposed method utilizes only the decomposed transient currents in time domain to calculate the RMS values of the fault currents of assumed fault in lossless mirror line. The location where the peak value is located is the calculated fault location. The second method uses the forward current in frequency domain to calculate the RMS values of the fault currents of assumed fault in loss mirror line. The location where the minimum value is located is the calculated fault location. The third method firstly calculates the RMS values of fault currents of assumed fault in lossless mirror line, and the fault location is selected from the peak value. Then the final fault location result is compensated by the pre-calculated error for each assumed fault location. A two-terminal AC transmission system is established for testing these three methods. The frequency dependent lines including homogeneous and inhomogeneous lines are taken into the simulated system for a large number of tests, respectively.
- 5 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 93858-93870
Open AccessA New Theory for Locating Line Fault in Power System: Simulation Part
Three time-reversal-based fault location methods are derived from the theoretical part of this paper, which are named currents-in-time-domain method, forward-currents-in-frequency-domain method, and forward-currents-in-frequency-domain-with-compensation method, respectively. The first proposed method utilizes only the decomposed transient currents in time domain to calculate the RMS values of the fault currents of assumed fault in lossless mirror line. The location where the peak value is located is the calculated fault location. The second method uses the forward current in frequency domain to calculate the RMS values of the fault currents of assumed fault in loss mirror line. The location where the minimum value is located is the calculated fault location. The third method firstly calculates the RMS values of fault currents of assumed fault in lossless mirror line, and the fault location is selected from the peak value. Then the final fault location result is compensated by the pre-calculated error for each assumed fault location. A two-terminal AC transmission system is established for testing these three methods. The frequency dependent lines including homogeneous and inhomogeneous lines are taken into the simulated system for a large number of tests, respectively.
- Open Access
A Fault Line Selection Method for DC Distribution Network Using Multiple Observers
This paper proposes a method of fault line selection for a DC distribution network. Firstly, the 1-mode current is calculated using the measured currents of the positive and the negative line. Then, it is time reversed and further decomposed by wavelet technology. Secondly, the lossless mirror line network is established according to the parameters and the topology of the DC distribution network. Thirdly, it is presumed that several virtual current sources are employed at the locations where the corresponding observers are, and the values of these current sources are equal to the processed 1-mode currents. Fourthly, a fault is placed at every point of the lossless mirror line network the RMS value of every assumed fault current is calculated. During this process, the phase coefficient of every lossless mirror line is set to vary along with the length of the line obeying Gaussian distribution. Finally, the line with the peak value of the RMS values of the currents is selected as the fault line. The result of fault line selection is updated using the fewest observers that are set in advance according to the initial result. A DC distribution network is simulated in PSCAD/EMDTC to verify the correctness of the proposed method.
Open AccessA Fault Line Selection Method for DC Distribution Network Using Multiple Observers
This paper proposes a method of fault line selection for a DC distribution network. Firstly, the 1-mode current is calculated using the measured currents of the positive and the negative line. Then, it is time reversed and further decomposed by wavelet technology. Secondly, the lossless mirror line network is established according to the parameters and the topology of the DC distribution network. Thirdly, it is presumed that several virtual current sources are employed at the locations where the corresponding observers are, and the values of these current sources are equal to the processed 1-mode currents. Fourthly, a fault is placed at every point of the lossless mirror line network the RMS value of every assumed fault current is calculated. During this process, the phase coefficient of every lossless mirror line is set to vary along with the length of the line obeying Gaussian distribution. Finally, the line with the peak value of the RMS values of the currents is selected as the fault line. The result of fault line selection is updated using the fewest observers that are set in advance according to the initial result. A DC distribution network is simulated in PSCAD/EMDTC to verify the correctness of the proposed method.
- Open Access
- 7 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 961-966
Wavelet‐based EMTR method for fault location of VSC‐HVDC transmission lines
A wavelet‐based electromagnetic time reversal method for locating faults in voltage source converter‐high‐voltage direct current (VSC‐HVDC) transmission lines is proposed in this study. This principle, firstly, is to use wavelet decomposition to filter the 1‐mode fault currents, which are recorded at ends of the transmission line. Secondly, the filtered currents are mirrored on time axes, which called time reversal. Thirdly, the time‐reversed currents are set as current sources at ends of the lossless mirror lines. Through assuming a fault at each point of line, the assumed fault currents are calculated, and the RMS of fault current at actual fault location is maximal according to a strict scientific proof. Theoretically, the Wavelet‐based Electromagnetic Time Reversal (WEMTR) method is robust against fault types and resistance. A multilevel converter‐HVDC system is established in Power Systems Computer‐Aided Design (PSCAD)/Electromagnetic Transients including DC (EMTDC) to verify the feasibility of the proposed method, and the transmission line is simulated by frequency independent phase model. The results show that, the fault location can be calculated exactly without high sampling rates.
- 7 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 961-966
Open AccessWavelet‐based EMTR method for fault location of VSC‐HVDC transmission lines
A wavelet‐based electromagnetic time reversal method for locating faults in voltage source converter‐high‐voltage direct current (VSC‐HVDC) transmission lines is proposed in this study. This principle, firstly, is to use wavelet decomposition to filter the 1‐mode fault currents, which are recorded at ends of the transmission line. Secondly, the filtered currents are mirrored on time axes, which called time reversal. Thirdly, the time‐reversed currents are set as current sources at ends of the lossless mirror lines. Through assuming a fault at each point of line, the assumed fault currents are calculated, and the RMS of fault current at actual fault location is maximal according to a strict scientific proof. Theoretically, the Wavelet‐based Electromagnetic Time Reversal (WEMTR) method is robust against fault types and resistance. A multilevel converter‐HVDC system is established in Power Systems Computer‐Aided Design (PSCAD)/Electromagnetic Transients including DC (EMTDC) to verify the feasibility of the proposed method, and the transmission line is simulated by frequency independent phase model. The results show that, the fault location can be calculated exactly without high sampling rates.
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1074 (1) , 012078
A novel fault-location method for VSC-MTDC transmission lines based on EMTR
This paper presents a novel method for locating faults on VSC-MTDC transmission lines using electromagnetic time reversal (EMTR) theory. A method named "First fault-segment, Second fault-location" is proposed. The observed currents are time-reversed and back-injected into the simulation system, which equals to the actual system. In this procedure, a fault is not necessary to be assumed in the simulation system. After fault segment has been screened, the fault location can be verified with minor calculation burden. Moreover, the performances of the EMTR-based technique are discussed under different time-asynchronous cases. The simulation test cases are: a five-terminal VSC-HVDC modified from the China Nan-au demonstration project. Considering the effects of protection and control system, the proposed method presents its straightforward application with low sampling rates and ultra-short time-windows, and robustness against fault type and fault impedance.
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1074 (1) , 012078
Open AccessA novel fault-location method for VSC-MTDC transmission lines based on EMTR
This paper presents a novel method for locating faults on VSC-MTDC transmission lines using electromagnetic time reversal (EMTR) theory. A method named "First fault-segment, Second fault-location" is proposed. The observed currents are time-reversed and back-injected into the simulation system, which equals to the actual system. In this procedure, a fault is not necessary to be assumed in the simulation system. After fault segment has been screened, the fault location can be verified with minor calculation burden. Moreover, the performances of the EMTR-based technique are discussed under different time-asynchronous cases. The simulation test cases are: a five-terminal VSC-HVDC modified from the China Nan-au demonstration project. Considering the effects of protection and control system, the proposed method presents its straightforward application with low sampling rates and ultra-short time-windows, and robustness against fault type and fault impedance.
- Open Access
- 23 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (10) , 2499-2507
EMTR‐based fault location for DC line in VSC‐MTDC system using high‐frequency currents
An improved electromagnetic time‐reversal (EMTR)‐based method is proposed for fault‐location of voltage‐source converter multi‐terminal high‐voltage direct current systems (VSC‐MTDC) transmission lines in this study. After a brief description of the EMTR, its application to lossless transmission line is mathematically demonstrated. Assuming that the DC faults are isolated by AC breakers, a window of adequate transients is used. If the protection has identified the faulted line correctly, only the recorded measurements at both ends of the faulted line should be time‐reversed and further calculated. To eliminate the influence from AC side, the 0/1‐mode observed currents and high‐pass elliptic filter are adopted. After the processed signals are set as current sources, the current effective value at each pre‐set fault position is calculated, with the peak value at the real fault‐location. The simulation test cases are based on a five‐terminal VSCHVDC modified from the China Nanau demonstration project. The results show that the improved method has good performance to deal DC line faults with high resistance and different types. Besides,, the results are not affected by measurement errors. Compared with the travelling wave‐based method, the proposed method does not need to employ high sampling rates and precise fault‐occurred time; meanwhile, it can achieve more precise results.
- 23 June 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (10) , 2499-2507
Open AccessEMTR‐based fault location for DC line in VSC‐MTDC system using high‐frequency currents
An improved electromagnetic time‐reversal (EMTR)‐based method is proposed for fault‐location of voltage‐source converter multi‐terminal high‐voltage direct current systems (VSC‐MTDC) transmission lines in this study. After a brief description of the EMTR, its application to lossless transmission line is mathematically demonstrated. Assuming that the DC faults are isolated by AC breakers, a window of adequate transients is used. If the protection has identified the faulted line correctly, only the recorded measurements at both ends of the faulted line should be time‐reversed and further calculated. To eliminate the influence from AC side, the 0/1‐mode observed currents and high‐pass elliptic filter are adopted. After the processed signals are set as current sources, the current effective value at each pre‐set fault position is calculated, with the peak value at the real fault‐location. The simulation test cases are based on a five‐terminal VSCHVDC modified from the China Nanau demonstration project. The results show that the improved method has good performance to deal DC line faults with high resistance and different types. Besides,, the results are not affected by measurement errors. Compared with the travelling wave‐based method, the proposed method does not need to employ high sampling rates and precise fault‐occurred time; meanwhile, it can achieve more precise results.