A. A. Bogdanov
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
A. A. Bogdanov has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Yu V Chichagov
Ioffe Institute, St. Petersburg, 194021 Russia
2 shared publicationsYu V Tuboltsev
Ioffe Institute, St. Petersburg, 194021 Russia
2 shared publicationsЮ.в. Тубольцев
Физико-технический институт им. А.Ф. Иоффе РАН, Санкт-Петербург, Россия
2 shared publications- Ю.в. Чичагов
Физико-технический институт им. А.Ф. Иоффе РАН, Санкт-Петербург, Россия
2 shared publications A A Bezbah
Joint Institute for Nuclear Research, Flerov Laboratory of Nuclear Reactions, Dubna, Moscow region, 141980 Russia
1 shared publicationA M Krassilchtchikov
Ioffe Institute, St. Petersburg, 194021 Russia
1 shared publication
Latest Publications
- 1 January 2021
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 91 (5) , 821
Температурная зависимость чувствительности кремниевых фотоумножителей в режиме пофотонной регистрации ультрафиолетового излучения
In the context of the development of a new detecting camera for the Cherenkov gamma-ray telescope TAIGA-IACT, the temperature dependences of the dark count rate and the efficiency of ultraviolet photon detection of two silicon avalanche photodetectors: OnSemi / SensL MicroFJ-60035 and Hamamatsu VUV4 S13371-6050CQ-02 at a wavelength of 277 nm were experimentally investigated. It is shown that the main characteristics of these detectors correspond to those declared by the manufacturers. Front-end readout electronics was developed and tested. Conclusions are drawn about the applicability of such detectors in the detecting cameras of Cherenkov gamma-ray telescopes.
- 1 January 2021
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 91 (5) , 821
Температурная зависимость чувствительности кремниевых фотоумножителей в режиме пофотонной регистрации ультрафиолетового излучения
In the context of the development of a new detecting camera for the Cherenkov gamma-ray telescope TAIGA-IACT, the temperature dependences of the dark count rate and the efficiency of ultraviolet photon detection of two silicon avalanche photodetectors: OnSemi / SensL MicroFJ-60035 and Hamamatsu VUV4 S13371-6050CQ-02 at a wavelength of 277 nm were experimentally investigated. It is shown that the main characteristics of these detectors correspond to those declared by the manufacturers. Front-end readout electronics was developed and tested. Conclusions are drawn about the applicability of such detectors in the detecting cameras of Cherenkov gamma-ray telescopes.
- Open Access
- 1 December 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1697 (1) , 012015
Measurements of the 277 nm photon detection efficiency of the OnSemi MicroFJ-60035 silicon photomultiplier
The article describes a method for absolute calibration of the photon detection efficiency of the OnSemi/SensL MicroFJ-60035 silicon photomultiplier by the Newport Power/Energy Meter 841-PE with the 883-UV photodiode sensor head, and the PicoQuant PLS-270 fast diode source of 277 nm ultraviolet emission. The dependences of the power of the detected emission and the number of ultraviolet photons on the distance to the source were obtained. The photon detection efficiency of the silicon photomultiplier was measured to be approximately 8% compared to the 9.6% level claimed by the manufacturer. It was also shown that, within the experimental setup, absorption of the 277 nm emission at paths in the air shorter than 1 m is not significant, and the angular distribution of the emission source is homogeneous. The obtained three-dimensional calibration surface of the dependence of the irradiance on the distance to the detector and the source intensity will be employed for development of a novel camera of the TAIGA-IACT telescope array.
- 1 December 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1697 (1) , 012015
Open AccessMeasurements of the 277 nm photon detection efficiency of the OnSemi MicroFJ-60035 silicon photomultiplier
The article describes a method for absolute calibration of the photon detection efficiency of the OnSemi/SensL MicroFJ-60035 silicon photomultiplier by the Newport Power/Energy Meter 841-PE with the 883-UV photodiode sensor head, and the PicoQuant PLS-270 fast diode source of 277 nm ultraviolet emission. The dependences of the power of the detected emission and the number of ultraviolet photons on the distance to the source were obtained. The photon detection efficiency of the silicon photomultiplier was measured to be approximately 8% compared to the 9.6% level claimed by the manufacturer. It was also shown that, within the experimental setup, absorption of the 277 nm emission at paths in the air shorter than 1 m is not significant, and the angular distribution of the emission source is homogeneous. The obtained three-dimensional calibration surface of the dependence of the irradiance on the distance to the detector and the source intensity will be employed for development of a novel camera of the TAIGA-IACT telescope array.
- Open Access
- 1 April 2020
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 57 (1-2) , 13-21
Modelling of SiPM Performance for Detection of Cherenkov Radiation from Extensive Air Showers in UV and Visible Ranges for Application at the TAIGA-IACT Telescope
A novel cluster of sensitive detectors based on silicon photomultipliers (SiPM) is being developed for the Cherenkov gamma-ray telescope TAIGA-IACT (Tunka valley, Republic of Buryatia, Russia). The cluster will be able to detect Cherenkov radiation from extensive air showers in two wide bands: 250–300 nm (UV) and 250–700 nm (visible and UV). Each pixel consists of a Winston cone, 4 SiPMs with the total sensitive area of 144 mm2, and readout electronics based on fast analogue memory. During operation in the UV band, a UV-bandpass filter is used to suppress cluster sensitivity in the visible range. In order to evaluate the detection efficiency of the selected SiPMs, a specific software simulator of SiPM output signal has been developed. This simulator takes into account such inherent parameters of SiPMs as total number of microcells, their recharge time, the dark count rate, the effective detection area, the quantum efficiency, the crosstalk between microcells, as well as conditions of SiPM operation, namely, the background noise and the Ohmic load in the readout (front-end) electronics. With this simulator it is possible to determine the expected trigger threshold under given conditions and parameters of selected detectors. Based on preliminary simulations, OnSemi MicroFJ-60035 SiPM chips have been chosen for the novel cluster of TAIGA-IACT. These SiPMs have sensible efficiency in the ultraviolet range (5–20% in the 250–300 nm band) and are distinguished by the presence of a fast output, which allows one to capture a low amplitude signal above a relatively high background noise.
- 1 April 2020
- Published by Walter de Gruyter GmbH in Latvian Journal of Physics and Technical Sciences
- Vol. 57 (1-2) , 13-21
Open AccessModelling of SiPM Performance for Detection of Cherenkov Radiation from Extensive Air Showers in UV and Visible Ranges for Application at the TAIGA-IACT Telescope
A novel cluster of sensitive detectors based on silicon photomultipliers (SiPM) is being developed for the Cherenkov gamma-ray telescope TAIGA-IACT (Tunka valley, Republic of Buryatia, Russia). The cluster will be able to detect Cherenkov radiation from extensive air showers in two wide bands: 250–300 nm (UV) and 250–700 nm (visible and UV). Each pixel consists of a Winston cone, 4 SiPMs with the total sensitive area of 144 mm2, and readout electronics based on fast analogue memory. During operation in the UV band, a UV-bandpass filter is used to suppress cluster sensitivity in the visible range. In order to evaluate the detection efficiency of the selected SiPMs, a specific software simulator of SiPM output signal has been developed. This simulator takes into account such inherent parameters of SiPMs as total number of microcells, their recharge time, the dark count rate, the effective detection area, the quantum efficiency, the crosstalk between microcells, as well as conditions of SiPM operation, namely, the background noise and the Ohmic load in the readout (front-end) electronics. With this simulator it is possible to determine the expected trigger threshold under given conditions and parameters of selected detectors. Based on preliminary simulations, OnSemi MicroFJ-60035 SiPM chips have been chosen for the novel cluster of TAIGA-IACT. These SiPMs have sensible efficiency in the ultraviolet range (5–20% in the 250–300 nm band) and are distinguished by the presence of a fast output, which allows one to capture a low amplitude signal above a relatively high background noise.
- 1 November 2019
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 62 (6) , 764-770
A Multichannel Spectrometric Readout System for Strip Semiconductor Detectors
A new readout system for strip semiconductor detectors has been developed based on a dedicated IDE1140 chip. The system consists of 64 spectrometric channels that provide readout of signals from detector strips. The source of the trigger signal can be either an external signal or a detector that measures the passage of an ionizing particle through the strips. The amplitude of the signal from this detector can also be used for particle spectrometry. The control and signal-readout unit for the IDE1140 chip has been designed on an EP3C16Q240 field-programmable gate array and is used for processing, storage, and transfer of acquired data. The main characteristics of the system are presented: the integral nonlinearity is <1% in the range of 5−160 fC, and the equivalent noise charge is 0.7 fC.
- 1 November 2019
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 62 (6) , 764-770
A Multichannel Spectrometric Readout System for Strip Semiconductor Detectors
A new readout system for strip semiconductor detectors has been developed based on a dedicated IDE1140 chip. The system consists of 64 spectrometric channels that provide readout of signals from detector strips. The source of the trigger signal can be either an external signal or a detector that measures the passage of an ionizing particle through the strips. The amplitude of the signal from this detector can also be used for particle spectrometry. The control and signal-readout unit for the IDE1140 chip has been designed on an EP3C16Q240 field-programmable gate array and is used for processing, storage, and transfer of acquired data. The main characteristics of the system are presented: the integral nonlinearity is <1% in the range of 5−160 fC, and the equivalent noise charge is 0.7 fC.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1400 (5) , 055050
Two-dimensional position-sensitive spectrometer for registration of ionizing radiation
A new two-coordinate position-sensitive spectrometer for the measurements of spatial and energy distribution of ionizing particles was developed. The sensitive elements of the device are two orthogonal 64 strip semiconductor detectors whose signals are read out by two Application-Specific Integrated Circuits (ASIC) IDE1140 comprising 64 spectrometric channels each. Control, pre-processing data acquisition and transfer to a computer are carried out using FPGA circuit EP3C16Q240. The main spectrometer characteristics obtained in the measurements are: equivalent noise charge of 0.7 fC and integral nonlinearity is below 1% in the range from 5 to 160 fC.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1400 (5) , 055050
Open AccessTwo-dimensional position-sensitive spectrometer for registration of ionizing radiation
A new two-coordinate position-sensitive spectrometer for the measurements of spatial and energy distribution of ionizing particles was developed. The sensitive elements of the device are two orthogonal 64 strip semiconductor detectors whose signals are read out by two Application-Specific Integrated Circuits (ASIC) IDE1140 comprising 64 spectrometric channels each. Control, pre-processing data acquisition and transfer to a computer are carried out using FPGA circuit EP3C16Q240. The main spectrometer characteristics obtained in the measurements are: equivalent noise charge of 0.7 fC and integral nonlinearity is below 1% in the range from 5 to 160 fC.
- 1 January 2017
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 87 (6) , 803
Черенковские гамма-телескопы: прошлое, настоящее, будущее. Проект ALEGRO
Черенковские гамма-телескопы: прошлое, настоящее, будущее. Проект ALEGRO
- 1 January 2017
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 87 (6) , 803
Черенковские гамма-телескопы: прошлое, настоящее, будущее. Проект ALEGRO
Черенковские гамма-телескопы: прошлое, настоящее, будущее. Проект ALEGRO