Jeon Min Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeon Min Kang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Dae Sung Ryu
Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
6 shared publications - Jung-Hoon Park
Department of Convergence Medicine Asan Medical Center University of Ulsan College of Medicine Seoul Republic of Korea
6 shared publications - Dong-Sung Won
Biomedical Engineering Research Center, Asan Institute for Life Sciences Asan Medical Center Seoul Republic of Korea
5 shared publications - Ji Won Kim
Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
5 shared publications - Song Hee Kim
Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea
5 shared publications - Yubeen Park
Biomedical Engineering Research Center, Asan Institute for Life Sciences Asan Medical Center Seoul Republic of Korea
5 shared publications
Latest Publications
- Open Access
High-Frequency Pulsed Electric Field Ablation in Beagle Model for Treatment of Prostate Cancer
Conventional irreversible electroporation (IRE) with low-frequency pulsed electric field (LF-PEF) is used to induce cell death; however, it has several disadvantages including a long procedure time and severe muscle contraction due to high-voltage electric field. This study investigates a novel IRE protocol with high-frequency pulsed electric field (HF-PEF) of 500 Hz repetition to ablate the prostate tissue in beagles for treatment of prostate cancer. A finite element analysis was performed to validate optimal electrical field strength for the procedure. In total, 12 beagles received HF-PEF of 500 Hz and were sacrificed at 4 h, 4 days, and 28 days (3 each). The remaining three beagles underwent sham procedure. The outcomes of HF-PEF were assessed by histological responses. HF-PEF successfully decellularized the prostate tissues 4 h after the treatment. The prostate glands, duct, and urethra were well preserved after IRE with HF-PEF. The ablated prostatic tissues were gradually regenerated and appeared similar to the original tissues 28 d after IRE with HF-PEF. Moreover, electrocardiography and hematology demonstrated that IRE with HF-PEF did not seriously affect the cardiac tissue. HF-PEF was effective and safe in the beagle prostate and effectively induced the ablation and gradually recovered with cellular regeneration.
Open AccessHigh-Frequency Pulsed Electric Field Ablation in Beagle Model for Treatment of Prostate Cancer
Conventional irreversible electroporation (IRE) with low-frequency pulsed electric field (LF-PEF) is used to induce cell death; however, it has several disadvantages including a long procedure time and severe muscle contraction due to high-voltage electric field. This study investigates a novel IRE protocol with high-frequency pulsed electric field (HF-PEF) of 500 Hz repetition to ablate the prostate tissue in beagles for treatment of prostate cancer. A finite element analysis was performed to validate optimal electrical field strength for the procedure. In total, 12 beagles received HF-PEF of 500 Hz and were sacrificed at 4 h, 4 days, and 28 days (3 each). The remaining three beagles underwent sham procedure. The outcomes of HF-PEF were assessed by histological responses. HF-PEF successfully decellularized the prostate tissues 4 h after the treatment. The prostate glands, duct, and urethra were well preserved after IRE with HF-PEF. The ablated prostatic tissues were gradually regenerated and appeared similar to the original tissues 28 d after IRE with HF-PEF. Moreover, electrocardiography and hematology demonstrated that IRE with HF-PEF did not seriously affect the cardiac tissue. HF-PEF was effective and safe in the beagle prostate and effectively induced the ablation and gradually recovered with cellular regeneration.
- Open Access
- 14 February 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 412
Silver Nanofunctionalized Stent after Radiofrequency Ablation Suppresses Tissue Hyperplasia and Bacterial Growth
Intraductal radiofrequency (RF) ablation combined with placement of a self-expandable metal stent (SEMS) for malignant biliary obstruction has risks such as stent- and heat-induced biliary sludge and restenosis. Here, we investigated the efficacy of a silver nanoparticles (AgNPs)-coated SEMS to inhibit tissue hyperplasia and bacterial growth caused by RF ablation with stent placement in the rabbit bile duct. The release behavior and antibacterial effects of AgNPs-coated SEMSs were evaluated. Then, SEMSs were successfully placed in all rabbits immediately after RF ablation. Ag ions were rapidly released at the beginning and then showed a gradual release behavior. The AgNPs-coated SEMS significantly inhibited bacterial activity compared to the uncoated SEMS (p < 0.05). Cholangiography and histological examination confirmed that the level of tissue hyperplasia was significantly lower in the AgNPs group than in the control group (all p < 0.05). Immunohistochemistry analyses revealed that TUNEL-, HSP 70-, and α-SMA-positive areas were significantly lower in the AgNPs group than in the control group (all p < 0.05). Intraductal RF ablation combined with nanofunctionalized stent placement represents a promising new approach for suppressing thermal damage as well as stent-induced tissue hyperplasia and bacterial growth.
- 14 February 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (2) , 412
Open AccessSilver Nanofunctionalized Stent after Radiofrequency Ablation Suppresses Tissue Hyperplasia and Bacterial Growth
Intraductal radiofrequency (RF) ablation combined with placement of a self-expandable metal stent (SEMS) for malignant biliary obstruction has risks such as stent- and heat-induced biliary sludge and restenosis. Here, we investigated the efficacy of a silver nanoparticles (AgNPs)-coated SEMS to inhibit tissue hyperplasia and bacterial growth caused by RF ablation with stent placement in the rabbit bile duct. The release behavior and antibacterial effects of AgNPs-coated SEMSs were evaluated. Then, SEMSs were successfully placed in all rabbits immediately after RF ablation. Ag ions were rapidly released at the beginning and then showed a gradual release behavior. The AgNPs-coated SEMS significantly inhibited bacterial activity compared to the uncoated SEMS (p < 0.05). Cholangiography and histological examination confirmed that the level of tissue hyperplasia was significantly lower in the AgNPs group than in the control group (all p < 0.05). Immunohistochemistry analyses revealed that TUNEL-, HSP 70-, and α-SMA-positive areas were significantly lower in the AgNPs group than in the control group (all p < 0.05). Intraductal RF ablation combined with nanofunctionalized stent placement represents a promising new approach for suppressing thermal damage as well as stent-induced tissue hyperplasia and bacterial growth.
- Open Access
- 30 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1516
Occlusive Properties of Transrenal Ureteral Occlusion Self-Expandable Metallic Stents: 3D-Printed Phantom and Ex Vivo Studies
Newly developed transrenal ureteral occlusion self-expanding metallic stents (SEMSs) are applied in patients with inoperable fistulas. In this study, the occlusive properties of M- and D-type occlusion SEMSs were investigated in 3D-printed phantom and ex vivo porcine urinary tracts. In the former, the mean bursting pressure causing leakage of contrast medium through the occlusion SEMS was relatively higher in M-types (42.8 ± 3.8 mmHg) than in D-types (38.8 ± 3.8 mmHg), without a statistical difference (p = 0.075). In the latter, the bursting pressure causing leakage through the M-type occlusion SEMS (110.7 ± 8.6 mmHg) was significantly higher than that of the D-type occlusion SEMS (93.8 ± 11.2 mmHg, p = 0.015); however, the mean bursting pressures causing contrast blowout did not differ between the two types (178.7 ± 11.2 mmHg vs. 176.2 ± 11.8 mmHg, p = 0.715). In conclusion, M- and D-type occlusion SEMSs showed similar efficacy in occlusive properties in the 3D phantom study; however, the M-type was superior in the ex vivo porcine urinary tract model. Further in vivo experimental studies are required to confirm these experimental results.
- 30 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1516
Open AccessOcclusive Properties of Transrenal Ureteral Occlusion Self-Expandable Metallic Stents: 3D-Printed Phantom and Ex Vivo Studies
Newly developed transrenal ureteral occlusion self-expanding metallic stents (SEMSs) are applied in patients with inoperable fistulas. In this study, the occlusive properties of M- and D-type occlusion SEMSs were investigated in 3D-printed phantom and ex vivo porcine urinary tracts. In the former, the mean bursting pressure causing leakage of contrast medium through the occlusion SEMS was relatively higher in M-types (42.8 ± 3.8 mmHg) than in D-types (38.8 ± 3.8 mmHg), without a statistical difference (p = 0.075). In the latter, the bursting pressure causing leakage through the M-type occlusion SEMS (110.7 ± 8.6 mmHg) was significantly higher than that of the D-type occlusion SEMS (93.8 ± 11.2 mmHg, p = 0.015); however, the mean bursting pressures causing contrast blowout did not differ between the two types (178.7 ± 11.2 mmHg vs. 176.2 ± 11.8 mmHg, p = 0.715). In conclusion, M- and D-type occlusion SEMSs showed similar efficacy in occlusive properties in the 3D phantom study; however, the M-type was superior in the ex vivo porcine urinary tract model. Further in vivo experimental studies are required to confirm these experimental results.
- Open Access
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 346
Interwoven versus Knitted Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Esophagus
This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sacrificed 4 weeks after the stent placement. The degree of stent-induced tissue hyperplasia on esophagography and histologic examination was compared between the groups. Stent placement was technically successful in all rats. Esophagography revealed significantly greater mean luminal diameter of the stented esophagus in the I-SEMS group than in the K-SEMS group (p < 0.001). Histologic examination revealed a significantly lower percentage of tissue hyperplasia area and a significantly thinner submucosal fibrosis in the I-SEMS group than in the K-SEMS group (all p < 0.001). There were no significant differences in the thickness of the epithelial layers (p = 0.290) and degree of inflammatory cell infiltration (p = 0.506). Formation of stent-induced tissue hyperplasia was evident with both I-SEMS and K-SEMS. Placement of I-SEMSs with a small cell size and high flexibility seems to be effective in suppressing stent-induced tissue hyperplasia compared with placement of K-SEMSs in rat esophageal models.
- 30 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 346
Open AccessInterwoven versus Knitted Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Esophagus
This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sacrificed 4 weeks after the stent placement. The degree of stent-induced tissue hyperplasia on esophagography and histologic examination was compared between the groups. Stent placement was technically successful in all rats. Esophagography revealed significantly greater mean luminal diameter of the stented esophagus in the I-SEMS group than in the K-SEMS group (p < 0.001). Histologic examination revealed a significantly lower percentage of tissue hyperplasia area and a significantly thinner submucosal fibrosis in the I-SEMS group than in the K-SEMS group (all p < 0.001). There were no significant differences in the thickness of the epithelial layers (p = 0.290) and degree of inflammatory cell infiltration (p = 0.506). Formation of stent-induced tissue hyperplasia was evident with both I-SEMS and K-SEMS. Placement of I-SEMSs with a small cell size and high flexibility seems to be effective in suppressing stent-induced tissue hyperplasia compared with placement of K-SEMSs in rat esophageal models.
- Open Access
- 25 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 4830
Antimigration Effects of the Number of Flaps on a Plastic Stent: Three-Dimensionally Printed Pancreatic Phantom and Ex Vivo Studies
Stent migration is a significant obstacle to successful stent placement. There has been no investigation of the effect and quantitative interpretation of flaps attached to a plastic stent (PS) on antimigration. The antimigration effects of the number of flaps on a PS in a 3D-printed pancreatic phantom (3DP) and extracted porcine pancreas (EPP) were investigated. Four PS types were used in this study: stent without flaps (type 1), stent with two flaps (type 2), stent with four horizontally made flaps (type 3), and stent with four vertically made flaps (type 4). The stents were measured and compared for antimigration force (AMF) in the 3DP and EPP using a customized measuring method and an integrated measuring device. The mean maximum AMFs (MAMFs) in types 2, 3, and 4 were significantly higher than that in type 1 (all p < 0.001). Moreover, the mean MAMFs in types 3 and 4 were significantly higher than that in type 2 (all p < 0.001). When the flaps were removed from the pancreatic duct, the AMF decreased rapidly. As the number of flaps increased, the antimigration effects significantly increased in the 3DP and EPP. However, the direction of the flaps did not affect the MAMF. The position of the flaps attached to the surface of the stent affected the AMF.
- 25 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 4830
Open AccessAntimigration Effects of the Number of Flaps on a Plastic Stent: Three-Dimensionally Printed Pancreatic Phantom and Ex Vivo Studies
Stent migration is a significant obstacle to successful stent placement. There has been no investigation of the effect and quantitative interpretation of flaps attached to a plastic stent (PS) on antimigration. The antimigration effects of the number of flaps on a PS in a 3D-printed pancreatic phantom (3DP) and extracted porcine pancreas (EPP) were investigated. Four PS types were used in this study: stent without flaps (type 1), stent with two flaps (type 2), stent with four horizontally made flaps (type 3), and stent with four vertically made flaps (type 4). The stents were measured and compared for antimigration force (AMF) in the 3DP and EPP using a customized measuring method and an integrated measuring device. The mean maximum AMFs (MAMFs) in types 2, 3, and 4 were significantly higher than that in type 1 (all p < 0.001). Moreover, the mean MAMFs in types 3 and 4 were significantly higher than that in type 2 (all p < 0.001). When the flaps were removed from the pancreatic duct, the AMF decreased rapidly. As the number of flaps increased, the antimigration effects significantly increased in the 3DP and EPP. However, the direction of the flaps did not affect the MAMF. The position of the flaps attached to the surface of the stent affected the AMF.
- Open Access
- 3 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1359
Technical Feasibility and Histological Analysis of Balloon-Expandable Metallic Stent Placement in a Porcine Eustachian Tube
There is a clinical need to develop a stent to treat obstructive and refractory Eustachian tube dysfunction (ETD) after balloon Eustachian tuboplasty. An animal model for stent placement in the Eustachian tube (ET) is needed to develop optimal designs and materials, as stents for ETD have not been clinically applied. The purpose of this study was to evaluate the technical feasibility of stent placement and histological changes in a porcine ET model. Six ETs were evaluated in three pigs. Cobalt–chrome alloy stents with two different diameters were placed in the left and right ET of each animal (right, 3.5 mm; left, 2.5 mm). The outcomes were assessed by endoscopic and fluoroscopic imaging during the procedure, computed tomography after the procedure, and by histological examinations. Stent placement was technically successful in all specimens after metallic guiding sheaths were located in the nasopharyngeal end of the ET. The mean luminal diameters of the proximal, middle, and distal portions of the larger stents in the right ETs were 3.48 mm, 2.54 mm, and 2.15 mm, respectively. In the left ETs using smaller stents, these values were 2.49 mm, 1.73 mm, and 1.42 mm, respectively. The diameters of the inserted stents differed by stent location and the original diameter. Histological findings showed tissue hyperplasia with severe inflammatory cell infiltration at 4 weeks after stent placement. In conclusion, stent placement into the porcine ET was technically feasible, and stent-induced tissue hyperplasia was significantly evident. The luminal configuration of the placed ET stent changed according to its non-elastic nature and anatomical features of the porcine ET. Using this model, ET stents of various materials and designs with anti-inflammatory or anti-proliferative drugs can be optimized for future treatments of ET dysfunction.
- 3 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1359
Open AccessTechnical Feasibility and Histological Analysis of Balloon-Expandable Metallic Stent Placement in a Porcine Eustachian Tube
There is a clinical need to develop a stent to treat obstructive and refractory Eustachian tube dysfunction (ETD) after balloon Eustachian tuboplasty. An animal model for stent placement in the Eustachian tube (ET) is needed to develop optimal designs and materials, as stents for ETD have not been clinically applied. The purpose of this study was to evaluate the technical feasibility of stent placement and histological changes in a porcine ET model. Six ETs were evaluated in three pigs. Cobalt–chrome alloy stents with two different diameters were placed in the left and right ET of each animal (right, 3.5 mm; left, 2.5 mm). The outcomes were assessed by endoscopic and fluoroscopic imaging during the procedure, computed tomography after the procedure, and by histological examinations. Stent placement was technically successful in all specimens after metallic guiding sheaths were located in the nasopharyngeal end of the ET. The mean luminal diameters of the proximal, middle, and distal portions of the larger stents in the right ETs were 3.48 mm, 2.54 mm, and 2.15 mm, respectively. In the left ETs using smaller stents, these values were 2.49 mm, 1.73 mm, and 1.42 mm, respectively. The diameters of the inserted stents differed by stent location and the original diameter. Histological findings showed tissue hyperplasia with severe inflammatory cell infiltration at 4 weeks after stent placement. In conclusion, stent placement into the porcine ET was technically feasible, and stent-induced tissue hyperplasia was significantly evident. The luminal configuration of the placed ET stent changed according to its non-elastic nature and anatomical features of the porcine ET. Using this model, ET stents of various materials and designs with anti-inflammatory or anti-proliferative drugs can be optimized for future treatments of ET dysfunction.