DWDong-Sung Won

Dong-Sung Won

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dong-Sung Won has a total of 73 co-authors. Here are the top co-authors by number of shared publications:

  • Jung-Hoon Park

    Department of Convergence Medicine Asan Medical Center University of Ulsan College of Medicine Seoul Republic of Korea

    13 shared publications
  • Yubeen Park

    Biomedical Engineering Research Center, Asan Institute for Life Sciences Asan Medical Center Seoul Republic of Korea

    11 shared publications
  • Ji Won Kim

    Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea

    7 shared publications
  • Chu Hui Zeng

    Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea

    5 shared publications
  • Dae Sung Ryu

    Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea

    5 shared publications
  • Jeon Min Kang

    Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea

    5 shared publications

Latest Publications

  • Open Access

    Efficacy and safety of a self‐expandable stent‐based endobiliary radiofrequency ablation: A preclinical study

    by Dong‐Sung Won, Yubeen Park, Ji Won Kim, Jinsu An, Hyung‐Sik Kim, Se‐Chul Lee, Youngjae Lee, Dongwook Oh, Jung‐Hoon Park

    The temperature‐controlled, bipolar self‐expandable stent (SES)‐based radiofrequency ablation (RFA) system represents a novel endobiliary RFA approach; however, its efficacy and safety must be verified before clinical application. The study aimed to investigate the efficacy and safety of SES–RFA in a porcine common bile duct (CBD) model. Ablation ranges were investigated using ex vivo porcine liver according to radiofrequency energy and time. For the in vivo study, radiofrequency parameters were set at 20 W for a 20‐mm electrode and 25 W for a 25‐mm electrode at 70°C for 120 s. Twelve pigs underwent endoscopic‐guided SES–RFA using either electrode ( n = 6 each). Animals were randomly euthanized at 24 h or 2 weeks after SES–RFA ( n = 3 per group). The RFA‐treated CBDs were evaluated using cholangiography, cholangioscopy, hematology, histology, and immunohistochemistry. The SES–RFA system was successfully deployed and retrieved through‐the‐scope without device failure. All animals survived until the study endpoint without RFA‐related adverse events, including ductal perforation, contrast leakage, or hematoma. Hepatobiliary levels of alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, and gamma‐glutamyl transferase were significantly higher at 2 weeks than at 24 h post‐SES–RFA (all p < 0.05). Ablation ranges and degree of mucosal damage, including collagen and TUNEL‐positive deposition, were significantly increased at 2 weeks than at 24 h (all p < 0.05). The temperature‐controlled bipolar SES–RFA system effectively and safely produced circumferential coagulative necrosis without ductal perforation in the porcine CBD. The system may be used for managing unresectable malignant biliary obstruction in anatomically challenging regions where conventional RFA is difficult to use.

  • Open Access

    Pressure‐Assisted Drug Delivery Using High‐Pressure Balloon Platform Improves Vascular Drug Penetration and Anti‐Restenotic Effects

    by Seung Jin Eo, So Yun Lim, Dong‐Sung Won, Ji Won Kim, Yubeen Park, Song Hee Kim, Hyemin Lee, Jung‐Min Ahn, Jun‐Kyu Park, Do‐Yoon Kang, et al.

    High‐pressure drug‐coated balloon (HP@DCB) angioplasty enhances vascular drug delivery by overcoming the limitations of passive diffusion‐based conventional noncompliant DCB (NC@DCB) systems. We developed a dual‐layer HP balloon catheter composed of an outer Nylon 12 layer and an inner Pebax 7233 layer, and evaluated its feasibility and therapeutic efficacy as a paclitaxel (PTX)‐coated platform. Shellac‐based PTX coating was uniformly applied to HP@DCB and NC@DCB, and coating thickness, drug amount, release behavior, and mechanical properties were compared. Pressure‐assisted drug penetration was assessed in a vascular‐mimicking agarose gel phantom using fluorescent PTX and confocal microscopy. In vivo efficacy was evaluated in a balloon injury‐induced rabbit iliac artery stenosis model using angiography, optical coherence tomography (OCT), histology, immunohistochemistry, and immunofluorescence examinations. Drug amount, coating thickness, and sustained drug release did not differ between groups. The mechanical robustness in HP@DCB was significantly greater than that in NC@DCB. HP@DCB produced significantly greater penetration depth and fluorescence‐positive area, indicating enhanced pressure‐assisted drug transfer. HP@DCB resulted in superior luminal patency, reduced neointimal hyperplasia, and favorable biological responses compared with that in NC@DCB and the sham control. These findings support DCB use based on a dual‐layered HP balloon platform as a promising next‐generation strategy for stenotic vascular lesion treatment.

  • Open Access

    Everolimus‐Coated Laser‐Cut Self‐Expandable Metallic Stent Suppresses Stent‐Induced Tissue Hyperplasia in a Rat Gastric Outlet

    by Yubeen Park, Chae Eun Yun, Dong‐Sung Won, Song Hee Kim, Ji Won Kim, Seung Jin Eo, Seokin Kang, Hyun‐Do Jung, Do Hoon Kim, Jun‐Kyu Park, et al.

    Malignant gastric outlet obstruction is a severe complication of gastrointestinal malignancies, often treated with self‐expandable metallic stents (SEMSs). However, conventional SEMSs are associated with in‐stent restenosis due to granulation tissue formation. This work aims to evaluate the efficacy and safety of everolimus‐coated laser‐cut SEMS in suppressing stent‐induced tissue hyperplasia in a rat gastric outlet model. Everolimus, a next‐generation antiproliferative drug, is applied to laser‐cut SEMS using ultrasonic spray coating. The mehcanical properties, drug release profiles, and surface morphology of the stents were analyzed. In vivo, 20 rats are divided into control (uncoated laser‐cut SEMS) and experimental (everolimus‐coated laser‐cut SEMS) groups. Endoscopic and histological analyzes reveal significantly reduced granulation tissue area, submucosal fibrosis thickness, and inflammatory cell infiltration in the everolimus group compared to controls ( p < 0.05). Immunohistochemical staining demonstrates decreased smooth muscle cell proliferation and increased apoptosis in the everolimus group. The drug‐coated stents exhibit drug release over 30 days and maintain structural integrity without stent‐related adverse events. These findings suggest that everolimus‐coated laser‐cut SEMS effectively suppress stent‐induced tissue hyperplasia while preserving mechanical properties, indicating its potential as a therapeutic strategy for improving stent patency in the early stage after stent placement.

  • Open Access

    Dual‐Layer Nanoengineered Urinary Catheters for Enhanced Antimicrobial Efficacy and Reduced Cytotoxicity

    by Dong‐Sung Won, Hyun Lee, Yubeen Park, Minjung Chae, Yu‐Chan Kim, Bumjin Lim, Min‐Ho Kang, Myoung‐Ryul Ok, Hyun‐Do Jung, Jung‐Hoon Park

    Catheter‐associated urinary tract infection (CAUTI) is the most common healthcare‐associated infection; however, current therapeutic strategies remain insufficient for standard clinical application. A novel urinary catheter featuring a dual‐layer nanoengineering approach using zinc (Zn) and silver nanoparticles (AgNPs) is successfully fabricated. This design targets microbial resistance, minimizes cytotoxicity, and maintains long‐term efficacy. The inner AgNPs layer provides immediate antibacterial effects against the UTI pathogens, while the outer porous Zn layer controls zero‐order Ag release and generates reactive oxygen species, thus enhancing long‐term bactericidal performance. Enhanced antibacterial properties of Zn/AgNPs‐coated catheters are observed, resulting in 99.9% of E. coli and 99.7% of S. aureus reduction, respectively. The Zn/AgNPs‐coated catheter significantly suppresses biofilm with sludge formation compared to AgNP‐coated and uncoated catheters (all, p < 0.05). The Zn/AgNP‐coated catheter in a rabbit model demonstrated a durable, effective barrier against bacterial colonization, maintaining antimicrobial properties during the catheter indwelling period with significantly reduced inflammation and epithelial disruption compared with AgNP and uncoated groups. This innovation has the potential to revolutionize the design of antimicrobial medical devices, particularly for applications requiring long‐term implantation. Although further preclinical studies are required to verify its efficacy and safety, this strategy seems to be a promising approach to preventing CAUTI‐related complications.


  • Open Access

    3D-printed versatile biliary stents with nanoengineered surface for anti-hyperplasia and antibiofilm formation

    by Hyun Lee, Dong-Sung Won, Sinwoo Park, Yubeen Park, Ji Won Kim, Ginam Han, Yuhyun Na, Min-Ho Kang, Seok Beom Kim, Heemin Kang, et al.

    Biliary strictures are characterized by the narrowing of the bile duct lumen, usually caused by surgical biliary injury, cancer, inflammation, and scarring from gallstones. Endoscopic stent placement is a well-established method for the management of biliary strictures. However, maintaining optimal mechanical properties of stents and designing surfaces that can prevent stent-induced tissue hyperplasia and biofilm formation are challenges in the fabrication of biodegradable biliary stents (BBSs) for customized treatment. This study proposes a novel approach to fabricating functionalized polymer BBSs with nanoengineered surfaces using 3D printing. The 3D printed stents, fabricated from bioactive silica poly(ε-carprolactone) (PCL) via a sol–gel method, exhibited tunable mechanical properties suitable for supporting the bile duct while ensuring biocompatibility. Furthermore, a nanoengineered surface layer was successfully created on a sirolimus (SRL)-coated functionalized PCL (fPCL) stent using Zn ion sputtering-based plasma immersion ion implantation (S-PIII) treatment to enhance the performance of the stent. The nanoengineered surface of the SRL-coated fPCL stent effectively reduced bacterial responses and remarkably inhibited fibroblast proliferation and initial burst release of SRL in vitro systems. The physicochemical properties and biological behaviors, including in vitro biocompatibility and in vivo therapeutic efficacy in the rabbit bile duct, of the Zn-SRL@fPCL stent demonstrated its potential as a versatile platform for clinical applications in bile duct tissue engineering.


  • Balloon neck-plasty to create a wide-necked aneurysm in the elastase-induced rabbit model

    by Dong-Sung Won, Ki Baek Lee, Jung-Hoon Park, Chu Hui Zeng, Mi Hyeon Kim, Deok Hee Lee

    Purpose The elastase-induced aneurysm (EIA) model in rabbits has been proposed for translational research; however, the adjustment of aneurysm neck size remains challenging. In this study, the technical feasibility and safety of balloon neck-plasty to create a wide-necked aneurysm in rabbit EIA model were investigated. Methods Male New Zealand White rabbits (N = 15) were randomly assigned to three groups: group A, EIA creation without neck-plasty; group B, neck-plasty immediately after EIA creation; group C, neck-plasty 4 weeks after EIA creation. The diameter of balloon used for neck-plasty was determined 1 mm larger than origin carotid artery diameter. All rabbits were euthanized 4 weeks after their final surgery. Aneurysm neck, height, dome-to-neck (D/N) ratio, and histologic parameters were compared among the groups. Results Aneurysm creation was technically successful in 14 out of 15 rabbits (93.3%), with one rabbit experiencing mortality due to an adverse anesthetic event during the surgery. Saccular and wide-necked aneurysms were successfully created in all rabbits. Aneurysm neck was significantly greater in groups B and C compared to group A (all P < .05). D/N ratio was significantly lower in groups B and C compared to group A (all P < .05). Additionally, tunica media thickness, vessel area, and luminal area were significantly greater in groups B and C compared to group A (all P < .05). These variables were found to be significantly greater in group B compared to group C (all P < .05). Conclusion The creation of a wide-necked aneurysm using balloon neck-plasty after elastase induction in rabbits has been determined to be technically feasible and safe.


  • Different routes of administering EW-7197 versus EW-7197⋅HBr for preventing peritoneal adhesion in a rat model

    by Chu Hui Zeng, Song Hee Kim, Jeon Min Kang, Yubeen Park, Dong-Sung Won, Ji Won Kim, Dae Sung Ryu, Soyeon Shim, Dae-Kee Kim, Ji Hoon Shin, et al.


  • Open Access

    High-Frequency Pulsed Electric Field Ablation in Beagle Model for Treatment of Prostate Cancer

    by Seung Jeong, Song Hee Kim, Hongbae Kim, Jeon Min Kang, Yubeen Park, Dong-Sung Won, Ji Won Kim, Dae Sung Ryu, Chu Hui Zeng, Jong Hoon Chung, et al.

    Conventional irreversible electroporation (IRE) with low-frequency pulsed electric field (LF-PEF) is used to induce cell death; however, it has several disadvantages including a long procedure time and severe muscle contraction due to high-voltage electric field. This study investigates a novel IRE protocol with high-frequency pulsed electric field (HF-PEF) of 500 Hz repetition to ablate the prostate tissue in beagles for treatment of prostate cancer. A finite element analysis was performed to validate optimal electrical field strength for the procedure. In total, 12 beagles received HF-PEF of 500 Hz and were sacrificed at 4 h, 4 days, and 28 days (3 each). The remaining three beagles underwent sham procedure. The outcomes of HF-PEF were assessed by histological responses. HF-PEF successfully decellularized the prostate tissues 4 h after the treatment. The prostate glands, duct, and urethra were well preserved after IRE with HF-PEF. The ablated prostatic tissues were gradually regenerated and appeared similar to the original tissues 28 d after IRE with HF-PEF. Moreover, electrocardiography and hematology demonstrated that IRE with HF-PEF did not seriously affect the cardiac tissue. HF-PEF was effective and safe in the beagle prostate and effectively induced the ablation and gradually recovered with cellular regeneration.


  • A modified method of elastase-induced saccular aneurysm creation in rabbits: Schematic representation of the method

    by Dong-Sung Won, Mi Hyeon Kim, Ki Baek Lee, Jong Tae Yoon, Yubeen Park, Deok Hee Lee

    Background: The purpose of our study was to investigate the safety and effectiveness of a modified technique using a short guiding catheter for instillation of elastase in comparison with the previously described method of creating elastase-induced aneurysm in rabbits. Methods: Following right common carotid artery (RCCA) access using an arterial sheath and inflating the Fogarty balloon in the subclavian artery, a short guiding catheter was used for the instillation of the elastase in the experimental group (n = 5) while it was performed with a microcatheter in the control group (n = 5). The procedure duration was recorded from the RCCA puncture to the sheath removal. The histological changes were characterized using H&E and Masson's trichrome (MT) staining. Results: The procedure time was 23 ± 2 min in the experimental group and 29 ± 2 min in the control group. All the rabbits (100%) in the experimental group survived without neurologic deficits, but two rabbits (40%) survived in the control group. All aneurysms were created in the saccular shape (100%) with a neck size of 2.3 ± 0.29 mm, a width of 2.75 ± 0.36 mm, and height of 6.37 ± 0.46 mm, and a dome to neck ratio of 1.21 ± 0.23. The aneurysm walls were partly thickened due to the degradation of the media tunica and adventitia proliferation with loss of the internal elastic lamina. Conclusion: By using a short guiding catheter, we could instill the elastase in a more effective and safe manner in the creation of the elastase-induced aneurysm model in rabbits.


  • Open Access

    Silver Nanofunctionalized Stent after Radiofrequency Ablation Suppresses Tissue Hyperplasia and Bacterial Growth

    by Yubeen Park, Dong-Sung Won, Ga-Hyun Bae, Dae Sung Ryu, Jeon Min Kang, Ji Won Kim, Song Hee Kim, Chu Hui Zeng, Wooram Park, Sang Soo Lee, et al.

    Intraductal radiofrequency (RF) ablation combined with placement of a self-expandable metal stent (SEMS) for malignant biliary obstruction has risks such as stent- and heat-induced biliary sludge and restenosis. Here, we investigated the efficacy of a silver nanoparticles (AgNPs)-coated SEMS to inhibit tissue hyperplasia and bacterial growth caused by RF ablation with stent placement in the rabbit bile duct. The release behavior and antibacterial effects of AgNPs-coated SEMSs were evaluated. Then, SEMSs were successfully placed in all rabbits immediately after RF ablation. Ag ions were rapidly released at the beginning and then showed a gradual release behavior. The AgNPs-coated SEMS significantly inhibited bacterial activity compared to the uncoated SEMS (p < 0.05). Cholangiography and histological examination confirmed that the level of tissue hyperplasia was significantly lower in the AgNPs group than in the control group (all p < 0.05). Immunohistochemistry analyses revealed that TUNEL-, HSP 70-, and α-SMA-positive areas were significantly lower in the AgNPs group than in the control group (all p < 0.05). Intraductal RF ablation combined with nanofunctionalized stent placement represents a promising new approach for suppressing thermal damage as well as stent-induced tissue hyperplasia and bacterial growth.