Jin Chai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jin Chai has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jing Zhao
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
2 shared publications - Wenliang Cao
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
2 shared publications - Yi Wang
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
2 shared publications - Yong Wang
Jilin University
2 shared publications A Soutar
Singapore Institute of Manufacturing Technology, 71 Nanyang Drive, Singapore 638075, Singapore
1 shared publicationBill Freeman
Singapore Pte. Ltd., Singapore, Singapore
1 shared publication
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 6201011
Physics-Constrained Deep Learning for Magnetic Anomaly Inversion of Buried Pipelines
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (10) , 6201011
Physics-Constrained Deep Learning for Magnetic Anomaly Inversion of Buried Pipelines
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Novel Magnetic Multitarget Localization Method Based on Energy Mutation Detection
Multitarget localization methods based on survey area data have significant efficiency advantages in applications such as unexploded ordnance detection. However, the existing methods still have many problems, including the target detection accuracy depends on the prior information, the parameter estimation accuracy is affected by the number of targets, the localization result is sensitive to the change of the magnetic moment direction, and the horizontal localization accuracy exhibits significant anisotropy. To solve these problems, this study proposes a novel magnetic multitarget localization method based on energy mutation detection. The method first transforms magnetic anomaly gradient vertical to the survey line (GVSL) into the energy domain using 2-D orthogonal basis functions (2D-OBFs), generating a new energy function. Then, the energy mutation detection method is used to identify target energy within local energy peaks. Finally, the target’s horizontal coordinates are determined based on the peak locations. Simulation results demonstrate the proposed method’s significant advantages over the total field 2-D OBF method. At a noise standard deviation (STD) of 20 nT/m, the method reduces the root-mean-square errors (RMSEs) of localization results in X- and Y-directions by 88.6% and 86.0%, respectively, while decreasing anisotropy in horizontal localization accuracy by 92.8%. Moreover, the method exhibits enhanced robustness to magnetic moment direction variations. In multitarget localization experiment, all targets were successfully identified, confirming the efficacy of the energy mutation detection method. Field experimental results closely match simulation data, underscoring the method’s practical utility.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Novel Magnetic Multitarget Localization Method Based on Energy Mutation Detection
Multitarget localization methods based on survey area data have significant efficiency advantages in applications such as unexploded ordnance detection. However, the existing methods still have many problems, including the target detection accuracy depends on the prior information, the parameter estimation accuracy is affected by the number of targets, the localization result is sensitive to the change of the magnetic moment direction, and the horizontal localization accuracy exhibits significant anisotropy. To solve these problems, this study proposes a novel magnetic multitarget localization method based on energy mutation detection. The method first transforms magnetic anomaly gradient vertical to the survey line (GVSL) into the energy domain using 2-D orthogonal basis functions (2D-OBFs), generating a new energy function. Then, the energy mutation detection method is used to identify target energy within local energy peaks. Finally, the target’s horizontal coordinates are determined based on the peak locations. Simulation results demonstrate the proposed method’s significant advantages over the total field 2-D OBF method. At a noise standard deviation (STD) of 20 nT/m, the method reduces the root-mean-square errors (RMSEs) of localization results in X- and Y-directions by 88.6% and 86.0%, respectively, while decreasing anisotropy in horizontal localization accuracy by 92.8%. Moreover, the method exhibits enhanced robustness to magnetic moment direction variations. In multitarget localization experiment, all targets were successfully identified, confirming the efficacy of the energy mutation detection method. Field experimental results closely match simulation data, underscoring the method’s practical utility.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
A method for measuring soil water content based on principal component analysis
Principal component analysis (PCA) has been applied in many aspects. To address the problem of measuring water content in soil, this paper proposes a method to measure soil water content based on the PCA. We used PCA to reduce the dimension of the data and processed the soil amplitude ratio frequency response spectra. First, we designed the measuring device and measured the soil amplitude ratio frequency response data of different water content, then we used the PCA to extract features from the frequency response spectra of different water contents, established a relationship model of soil water content, and finally, we solved the model, the maximum error between the calculation results and the actual water content was no more than 0.85%. Subsequently, we carried out experimental verification, and we measured six kinds of soil with known water content by this method. The experimental results showed that the maximum error did not exceed 1.16%, and the average error was 0.71%. Thus, the proposed method can provide a useful way of measuring soil water content.
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Open AccessA method for measuring soil water content based on principal component analysis
Principal component analysis (PCA) has been applied in many aspects. To address the problem of measuring water content in soil, this paper proposes a method to measure soil water content based on the PCA. We used PCA to reduce the dimension of the data and processed the soil amplitude ratio frequency response spectra. First, we designed the measuring device and measured the soil amplitude ratio frequency response data of different water content, then we used the PCA to extract features from the frequency response spectra of different water contents, established a relationship model of soil water content, and finally, we solved the model, the maximum error between the calculation results and the actual water content was no more than 0.85%. Subsequently, we carried out experimental verification, and we measured six kinds of soil with known water content by this method. The experimental results showed that the maximum error did not exceed 1.16%, and the average error was 0.71%. Thus, the proposed method can provide a useful way of measuring soil water content.
- 14 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 50-53
Transparent-Reflective Switchable Glass Using Multi-layered Transition Metal Dichalcogenides
The molybdenum disulfide ($MoS_{2}$) offers high charge density and well-ordered layer structure for good charge balance in the transparent-reflective switchable glass. The electrically actuated device with $MoS_{2}$ counter electrode shows large modulation in the light reflectance between the reflective mirror and transparent bleached states. Under zero power consumption, 95 % of light reflectance of the mirror-state device can be maintained for 80 minutes, paving it a promising technology for energy-efficient applications.- 14 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 50-53
Transparent-Reflective Switchable Glass Using Multi-layered Transition Metal Dichalcogenides
The molybdenum disulfide ($MoS_{2}$) offers high charge density and well-ordered layer structure for good charge balance in the transparent-reflective switchable glass. The electrically actuated device with $MoS_{2}$ counter electrode shows large modulation in the light reflectance between the reflective mirror and transparent bleached states. Under zero power consumption, 95 % of light reflectance of the mirror-state device can be maintained for 80 minutes, paving it a promising technology for energy-efficient applications.- 2 June 2009
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 113 (25) , 10939-10946
Size Dependence of the 2p3/2 and 3d5/2 Binding Energy Shift of Ni Nanostructures: Skin-Depth Charge and Energy Trapping
- 2 June 2009
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 113 (25) , 10939-10946
Size Dependence of the 2p3/2 and 3d5/2 Binding Energy Shift of Ni Nanostructures: Skin-Depth Charge and Energy Trapping
- 1 January 2004
- Published by Elsevier in Applied Surface Science
- Vol. 222 (1-4) , 110-115
A novel technique for finely controlled near-infrared beam transmission of titania
- 1 January 2004
- Published by Elsevier in Applied Surface Science
- Vol. 222 (1-4) , 110-115
A novel technique for finely controlled near-infrared beam transmission of titania