M. Parody Guzmán
Research Subjects
M. Parody Guzmán has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Louis Zani
Fusion for Energy, Garching, Germany
4 shared publications - Alexandre Louzguiti
ITER Organization, Saint-Paul-lez-Durance, France
2 shared publications - Alfredo Portone
Fusion for Energy, Barcelona, Spain
2 shared publications - Francesca Cau
F4E, Barcelona, Spain
2 shared publications - Jose Lorenzo
Fusion for Energy, Barcelona, Spain
2 shared publications - Quentin Le Coz
CEA-IRFM, St-Paul Lez Durance, France
2 shared publications
Latest Publications
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Simulation of the JT-60SA Supercritical Helium Toroidal Field Coil Loop During Fast Safety Discharge Using Simcryogenics. Comparison With Experimental Data and Extrapolation to Higher Currents
The JT-60SA fusion experiment is under commissioning at Naka, Japan (2023). When a fast safety discharge (FSD) of the toroidal field coils (TFC) current occurs, the procedure is to close the supercritical helium (SHe) supply of the magnets from the auxiliary cold box to release the heated and pressurized helium of the coil and its structure into a quench tank to avoid over-pressurizing the loop. To restart normal operation, the evaporated helium must be re-liquefied to return into the loop. This can take up to 48 hours. The maximal pressure reached in the loop during FSD has to be predicted to assess the necessity to open the quench relief valve (QRV). If opening the QRV is not necessary, it will save time during the commissioning and during future operation. Simcryogenics (Bonne et al., 2020) is used to model the whole cryo-magnetic loop 1 dedicated to supply SHe for the TFC Winding Pack (WP), the TFC structures and CS structures. It means that the piping, Cable in Conduit Conductor (CICC), TFC structures and CS structures, which belong to the TFC loop, are modeled thermally and hydraulically. The heat loads that are generated during FSD and that are applied to the simulation are issued from an ad-hoc simulation. This paper presents the comparison between experimental and predicted behavior of TFC FSD at 15 kA and 18 kA and extrapolates it for higher current, such as the nominal current of 25.7 kA. This paper gives the value of the FSD current for which the TFC loop helium must be released into the quench tank, meaning that the loop pressure would be expected to lead to the safety valve opening.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Simulation of the JT-60SA Supercritical Helium Toroidal Field Coil Loop During Fast Safety Discharge Using Simcryogenics. Comparison With Experimental Data and Extrapolation to Higher Currents
The JT-60SA fusion experiment is under commissioning at Naka, Japan (2023). When a fast safety discharge (FSD) of the toroidal field coils (TFC) current occurs, the procedure is to close the supercritical helium (SHe) supply of the magnets from the auxiliary cold box to release the heated and pressurized helium of the coil and its structure into a quench tank to avoid over-pressurizing the loop. To restart normal operation, the evaporated helium must be re-liquefied to return into the loop. This can take up to 48 hours. The maximal pressure reached in the loop during FSD has to be predicted to assess the necessity to open the quench relief valve (QRV). If opening the QRV is not necessary, it will save time during the commissioning and during future operation. Simcryogenics (Bonne et al., 2020) is used to model the whole cryo-magnetic loop 1 dedicated to supply SHe for the TFC Winding Pack (WP), the TFC structures and CS structures. It means that the piping, Cable in Conduit Conductor (CICC), TFC structures and CS structures, which belong to the TFC loop, are modeled thermally and hydraulically. The heat loads that are generated during FSD and that are applied to the simulation are issued from an ad-hoc simulation. This paper presents the comparison between experimental and predicted behavior of TFC FSD at 15 kA and 18 kA and extrapolates it for higher current, such as the nominal current of 25.7 kA. This paper gives the value of the FSD current for which the TFC loop helium must be released into the quench tank, meaning that the loop pressure would be expected to lead to the safety valve opening.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Extended Analysis of TF02 Feeder Performance and Risks During Operation in JT-60SA Tokamak
The upgrade to JT-60SA tokamak (R = 3 m, a = 1.2 m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, the magnet system commissioning was initiated, undergoing cool-down and energization of the 18 Nb-Ti Toroidal Field (TF) coils (400 tonnes) up to full nominal current. TF energization was smoothly processed but it was observed during current load a higher outlet temperature increase of TF02 coil versus others, indicating a higher resistance in this coil circuit and therefore a possible risk in future operation. The present paper analyses the different risk factors that can impact the TF operation safety margins and their quantitative contribution. To this end on the one hand ad-hoc thermal & thermo-hydraulic models were developed by CEA and F4E to represent the TF02 whole circuit including feeder zone where high resistance is suspected to be located. The outcomes of those models on chosen TF and PF current scenarios including transient loads and their impact on temperature margin in risky zones such as terminal joint (TJ) are presented. On the another hand a 3D electrical circuit of TJ was modelled using TF cables tomography, giving a realistic quantitative insight into local current distribution, therefore on current sharing temperature. The analyses outcomes synthesis is depicted under strategic considerations and tentatively contributes to establishing guidelines for future operation scenarios in which magnets will undergo demanding conditions.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Extended Analysis of TF02 Feeder Performance and Risks During Operation in JT-60SA Tokamak
The upgrade to JT-60SA tokamak (R = 3 m, a = 1.2 m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, the magnet system commissioning was initiated, undergoing cool-down and energization of the 18 Nb-Ti Toroidal Field (TF) coils (400 tonnes) up to full nominal current. TF energization was smoothly processed but it was observed during current load a higher outlet temperature increase of TF02 coil versus others, indicating a higher resistance in this coil circuit and therefore a possible risk in future operation. The present paper analyses the different risk factors that can impact the TF operation safety margins and their quantitative contribution. To this end on the one hand ad-hoc thermal & thermo-hydraulic models were developed by CEA and F4E to represent the TF02 whole circuit including feeder zone where high resistance is suspected to be located. The outcomes of those models on chosen TF and PF current scenarios including transient loads and their impact on temperature margin in risky zones such as terminal joint (TJ) are presented. On the another hand a 3D electrical circuit of TJ was modelled using TF cables tomography, giving a realistic quantitative insight into local current distribution, therefore on current sharing temperature. The analyses outcomes synthesis is depicted under strategic considerations and tentatively contributes to establishing guidelines for future operation scenarios in which magnets will undergo demanding conditions.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Thermo-Hydraulic Modeling of JT-60SA TF02 Coil and Feeder for First Operation Predictions
During the commissioning phase of JT-60SA magnet system, which included the cool-down in 2020 and the energization of the 18 Toroidal Field (TF) coils up to a nominal current of 25.7 kA in 2021, the combined helium flow issued from TF02 coil and feeder outlet showed a higher temperature profile than the one of the other TF coils when energized, pointing to the presence of an extra joint resistance in the TF02 and associated feeder circuit. To analyze this temperature excursion and the potential associated risks, the TF02 hydraulic circuit and feeder have been modelled with the thermo-hydraulic CryoSoft suite in the framework of a collaboration between Fusion for Energy and CEA. This paper describes the different numerical models developed along with simplifying analytical strategies, comprising detailed THEA models of the TF02 feeder and a model of the TF02 hydraulic circuit in FLOWER. These models consider the variable thermal and hydraulic geometry along the feeder length, include static and transient heat loads from different sources, and account for the heat exchange between the feeder and the TF02 Lateral Pancake at the feeder Terminal Joint (TJ), thus enabling a detailed description of the helium temperature variations in the system. In addition to the static energization load, the discharge of the Equilibrium Field coils has been modelled and its impact on the helium temperature at the outlet and feeder TJ analyzed. Model results show that the temperature excursion due to a faulty joint in the feeder should not put at risk the operation of TF02 coil.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Thermo-Hydraulic Modeling of JT-60SA TF02 Coil and Feeder for First Operation Predictions
During the commissioning phase of JT-60SA magnet system, which included the cool-down in 2020 and the energization of the 18 Toroidal Field (TF) coils up to a nominal current of 25.7 kA in 2021, the combined helium flow issued from TF02 coil and feeder outlet showed a higher temperature profile than the one of the other TF coils when energized, pointing to the presence of an extra joint resistance in the TF02 and associated feeder circuit. To analyze this temperature excursion and the potential associated risks, the TF02 hydraulic circuit and feeder have been modelled with the thermo-hydraulic CryoSoft suite in the framework of a collaboration between Fusion for Energy and CEA. This paper describes the different numerical models developed along with simplifying analytical strategies, comprising detailed THEA models of the TF02 feeder and a model of the TF02 hydraulic circuit in FLOWER. These models consider the variable thermal and hydraulic geometry along the feeder length, include static and transient heat loads from different sources, and account for the heat exchange between the feeder and the TF02 Lateral Pancake at the feeder Terminal Joint (TJ), thus enabling a detailed description of the helium temperature variations in the system. In addition to the static energization load, the discharge of the Equilibrium Field coils has been modelled and its impact on the helium temperature at the outlet and feeder TJ analyzed. Model results show that the temperature excursion due to a faulty joint in the feeder should not put at risk the operation of TF02 coil.