NBNesrin Büyükbaş

Nesrin Büyükbaş

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nesrin Büyükbaş has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of antimicrobial efficacy of different disinfectants on the biofilm formation in dental unit water systems using dip slide and conventional methods: A pilot study

    by Pelin Özmen, Hilal Erdoğan, Aslıhan Güngördü, Bülent Pişkin, Funda Kont Çobankara, Serdar Sütcü, Nesrin Şahin

    Objective: Biofilm formation in dental waterlines brings opportunistic infections, especially for immunosuppressive patients. This study aimed to determine biofilm‐forming microorganisms by various methods and investigate disinfectants' effects on biofilm.Materials & Methods: In the study, samples were obtained from the waterlines of 10–15 aged six dental units, before (0 min.) and after chlorine dioxide (ClO2) and hypochlorous acid (HOCl) treatment (1, 5, 10, 20, and 30 min.), and total colony counts were performed using conventional surface smear method (SSM) and dip slide method (DSM). The Congo red agar and Christensen methods were used to examine the biofilm‐forming properties of the isolates. Monitoring of biofilm presence was also visualized by SEM scanning.Results: When DSM and SSM are compared in all units where ClO2 and HOCl are applied, DSM can detect bacterial growth even during periods of greater exposure to disinfectant application. Although DSM can achieve a value approaching 3% even at the 10th minute in units treated with HOCl; SSM does not show reproduction at the same disinfectant exposure and duration; It was observed that in the units where ClO2 was applied, the growth was no longer observed at the 10th minute with DSM, and SSM, 50% growth in the first minute of the units treated with ClO2 could not be detected in the 5th minute.Conclusions: It is concluded that it can be advisable to routinely disinfect the dental unit water systems with non‐toxic doses of ClO2 application before patient treatments in clinics and also to perform contamination controls at regular intervals with DSM, which is a sensitive and very practical method.Research highlights: It has been observed that the dip slide method can count bacteria more sensitively than conventional methods in dental water systems without the need for experienced personnel and equipment. The difference between biofilm formation in water systems before and after disinfectant exposure in SEM examinations is remarkable. The effects of ClO2 and HOCl on biofilm were investigated and bacterial growth was inhibited in dental units between 5 and 10 minutes with both disinfectants.


  • Open Access

    Effects of Different Chemical Disinfectants on Physical Properties of Denture Base Acrylic Resin Material

    by Nurten Baysal, Tuba Yılmaz Savaş, Barış Filiz Erol, Hilal Erdoğan, Onur Altuğ Sakallı, Nesrin Büyükbaş

    Statement of the problem: There is still a lack of data regarding the effects of exposure to different chemical disinfectants on the color stability, light translucency, and surface roughness of dentures is limited. Objective: This study aims to investigate the impact of six different chemical disinfectants on the color change, translucency, and surface roughness properties of heat-polymerized denture base acrylic resin. Material & Methods: Totally 70 rectangular blocks (10×10×2 mm) were polymerized from the heat-polymerized acrylic denture base resin material. The surfaces of the specimens polished with 600- and 1200-grit waterproof abrasive paper. Each specimen were immersed in six denture cleansers. The total immersion time of a specimen in selected chemical disinfectant was 36 hours. Color changes, translucency and, surface roughness were measured after immersion process. The results were statistically analyzed with 1-way ANOVA and the Tukey honestly significant difference (HSD) test (α=.05). Results: According to the results of the 1-way ANOVA test, significant differences were observed in the ∆E00, TP00 and Ra properties among the acrylic resin groups following immersion in chemical disinfectants (P<0.05). ΔE00 value of the CG group was significantly higher than that of the NS, SH, G, and E groups (P<0.05). The TP00 values of the NS and G groups were demonstrated significant differences compared with C group (P<0.05). The Ra values of the SH, SP, G, CG and, E groups were significantly increased after immersion process, in comparison with C and NS groups (P<0.05). Conclusions: Color stability, translucency and surface roughness of the denture base heat polymerized acrylic resin is influenced by chemical disinfectants.

  • Open Access

    Comparison of Shade Matching Performance of Dental Professionals and Untrained Individuals in Visual Shade Matching Method

    by Bülent Pişkin, Barış Filiz Erol, Bedri Beydemir, Nurten Baysal, Onur Altuğ Sakallı, Nesrin Büyükbaş

    Statement of the problem: It is unclear how the success of color selection with custom shade guides is influenced by the observer's level of color education and the type of light source. Objective: The aim of this study is to compare the color matching ability under different light sources between observers with and without color education and to investigate in which shade tabs they are more successful, using a custom-made shade guide. Materials & Methods: The study included 5 prosthodontists (PD), 5 general dentists (GD), 5 dental ceramists (DC), 5 removable denture technicians (RDT), and 10 participants with no color education (NP). Using dentin powder from feldspathic dental porcelain, 2 sets of 16 shade tabs matching those in the Vita Lumin Classic shade guide were produced. The Lab values of the produced shade tabs with the same shade code were measured using a colorimeter device, and those with ΔE values below 0.1 were used for shade matching. Each participant conducted a total of 48 shade matches under 3 different light sources (tungsten-TG, fluorescent-FL, and D65). Results: It was found that the shade matching success of dental professionals in the PD, GD, RDT, and DC groups significantly differed from that of the participants in the NP group (χ² = 23.417; P< 0.001). Shade matches conducted under the D65 light source were more successful than those under the TG and FL light sources, and participants were found to match shade tabs with higher saturation, such as A4 and C4, more successfully. Conclusions: Color matching performed with a custom color scale is influenced by the observer's training and the light source. As the saturation of shade tabs increases, the matching success also increases.