Effects of Different Chemical Disinfectants on Physical Properties of Denture Base Acrylic Resin Material
Open Access
- 30 December 2023
- journal article
- Published by Cappadocia University in Kapadokya Üniversitesi
- Vol. 3 (2) , 86-98
Abstract
Statement of the problem: There is still a lack of data regarding the effects of exposure to different chemical disinfectants on the color stability, light translucency, and surface roughness of dentures is limited. Objective: This study aims to investigate the impact of six different chemical disinfectants on the color change, translucency, and surface roughness properties of heat-polymerized denture base acrylic resin. Material & Methods: Totally 70 rectangular blocks (10×10×2 mm) were polymerized from the heat-polymerized acrylic denture base resin material. The surfaces of the specimens polished with 600- and 1200-grit waterproof abrasive paper. Each specimen were immersed in six denture cleansers. The total immersion time of a specimen in selected chemical disinfectant was 36 hours. Color changes, translucency and, surface roughness were measured after immersion process. The results were statistically analyzed with 1-way ANOVA and the Tukey honestly significant difference (HSD) test (α=.05). Results: According to the results of the 1-way ANOVA test, significant differences were observed in the ∆E00, TP00 and Ra properties among the acrylic resin groups following immersion in chemical disinfectants (P<0.05). ΔE00 value of the CG group was significantly higher than that of the NS, SH, G, and E groups (P<0.05). The TP00 values of the NS and G groups were demonstrated significant differences compared with C group (P<0.05). The Ra values of the SH, SP, G, CG and, E groups were significantly increased after immersion process, in comparison with C and NS groups (P<0.05). Conclusions: Color stability, translucency and surface roughness of the denture base heat polymerized acrylic resin is influenced by chemical disinfectants.Keywords
This publication has 19 references indexed in Scilit:
- Effect of microwave disinfection on mechanical properties of denture base acrylic resinJournal of the Mechanical Behavior of Biomedical Materials, 2010
- Hardness and surface roughness of reline and denture base acrylic resins after repeated disinfection proceduresThe Journal of Prosthetic Dentistry, 2009
- Influence of denture cleansers on the color stability of three types of denture base acrylic resinThe Journal of Prosthetic Dentistry, 2009
- Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersionThe Journal of Prosthetic Dentistry, 2005
- A between-patient disinfection method to control water line contamination and biofilm inside dental unitsJournal of Hospital Infection, 2004
- In vitro color stability, stain resistance, and water sorption of four removable gingival flange materialsThe Journal of Prosthetic Dentistry, 2003
- Accuracy of polyether and addition silicone after long-term immersion disinfectionThe Journal of Prosthetic Dentistry, 1997
- Effects of chemical disinfectants on the surface characteristics and color of denture resinsThe Journal of Prosthetic Dentistry, 1997
- Effects of laboratory disinfecting agents on color stability of denture acrylic resinsThe Journal of Prosthetic Dentistry, 1991
- Sanitization of dentures by several denture hygiene methodsThe Journal of Prosthetic Dentistry, 1984